Comparison of the Balloon-Expandable Edwards Valve and Self-Expandable CoreValve Evolut R or Evolut PRO System for the Treatment of Small, Severely Dysfunctional Surgical Aortic Bioprotheses. The 'LYTEN' Trial
NCT03520101 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 102
Last updated 2026-03-27
Summary
The treatment with transcatheter aortic valve implantation (TAVI) of patients with small (≤23mm) surgical bioprostheses remains a challenge due to the increased transvalvular residual gradients and high rates of severe prosthesis-patient mismatch (PPM) following the procedure.
Conditions
- Aortic Valve Stenosis
- Regurgitation, Aortic
- Prosthesis Failure
Interventions
- PROCEDURE
-
TAVI_ViV procedure with Edwards valve
The TAVR procedure will be performed following the standards of each participating center. No restriction or specific recommendation will be given regarding the approach, general vs. local anesthesia, imaging guidance during the TAVI procedure, and post-procedural TAVI management. The decision for selecting either a 20 or 23mm Edwards valve will be based on 3D CT measurements of the mean inner diameter of the surgical aortic bioprosthesis. A 23mm Sapien 3 valve will be recommended if the inner diameter is \>18 mm, and a 20mm valve will be selected if the mean inner diameter is ≤18 mm.
- PROCEDURE
-
TAVI_ViV procedure with CoreValve system
The TAVR procedure will be performed following the standards of each participating center. No restriction or specific recommendation will be given regarding the approach, general vs. local anesthesia, imaging guidance during the TAVI procedure, and post-procedural TAVI management. A 23mm valve will be recommended in all patients randomized to the self-expanding CoreValve Evolut R system.
Sponsors & Collaborators
-
Centre de Recherche de l'Institut Universitaire de Cardiologie et de Pneumologie de Quebec
lead OTHER
Principal Investigators
-
Josep Rodés-Cabau, MD · Institut universitaire de cardiologie et de pneumologie de Québec, University Laval
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-05-10
- Primary Completion
- 2022-02-22
- Completion
- 2030-05-31
Countries
- Canada
Study Locations
More Related Trials
-
CoreValve™ Evolut R™ 34 mm System Registry (CoreValve34)
NCT03621709 ·Status: UNKNOWN
-
Cerebrovascular EveNts in Patients Undergoing TranscathetER Aortic Valve Implantation With Balloon-expandable Valves Versus Self-expandable Valves.
NCT03588247 ·Status: COMPLETED
-
Accuracy of Using 2D Transesophageal Echocardiography Compared to Balloon Sizing in Determining Valve Size During Transcatheter Aortic Valve Implantation
NCT04242225 ·Status: UNKNOWN
-
Multicenter Study Evaluating the Efficacy of an Intervention Aimed At Reducing the Length of Stay After Transfemoral Transcatheter Aortic Valve Implantation
NCT04503655 ·Status: COMPLETED ·Phase: NA
-
Impact of Predilatation Between Self-expanding Valves
NCT04157920 ·Status: COMPLETED ·Phase: NA
-
Optimized Expansion of the Implanted Transcatheter Aortic Valve
NCT07042529 ·Status: RECRUITING ·Phase: NA
-
A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial
NCT01645202 ·Status: COMPLETED ·Phase: NA
-
In-vitro Benchmarking of Currently Available Heart Valve Prostheses for Surgical and Percutaneous Treatment of Aortic Stenosis With Small Annulus, Followed by In-vivo Validation
NCT06859255 ·Status: RECRUITING ·Phase: NA
-
Bioprothetic Valve Versus Mechanical Valve of Bioprothetic Valve Versus Mechanical Valve
NCT06041308 ·Status: RECRUITING
-
Renato® Transcatheter Valve-in-Valve System Multicenter Registry Trial (China)
NCT07174531 ·Status: COMPLETED ·Phase: NA
-
Evaluate the Transcatheter Artificial Aortic Valve and Transcatheter Artificial Heart Values Delivery System
NCT03788590 ·Status: UNKNOWN ·Phase: NA
-
SecOnd-generation seLf-expandable Versus Balloon-expandable Valves and gEneral Versus Local Anesthesia in TAVI
NCT02737150 ·Status: UNKNOWN ·Phase: NA
-
Safety & Efficacy of the J-Valve Ausper System in Patients With Severe Aortic Stenosis and/or Aortic Regurgitation
NCT03025971 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy of Emergent TAVI in Patients With Severe AS
NCT05528211 ·Status: NOT_YET_RECRUITING
-
Behavior of Valve Leaflets Following Aortic Valve Implant
NCT03200574 ·Status: COMPLETED ·Phase: NA
-
Short- and Medium-term Results of New Generation Aortic
NCT05055089 ·Status: UNKNOWN
-
Bicuspid Aortic Valve Replacement: Evaluation of Transcatheter Versus Surgery-Pilot Trial
NCT06817148 ·Status: RECRUITING ·Phase: NA
-
Transcatheter Aortic Valve Implantation Versus Standard Surgical Aortic Valve Replacement
NCT05261204 ·Status: ENROLLING_BY_INVITATION
-
Outcomes for Patients With Ascending Aortic Dilation Who Underwent TAVR
NCT07148973 ·Status: COMPLETED
-
CoreValve™ Evolut R™ FORWARD Study
NCT02592369 ·Status: COMPLETED
-
Early Outcomes of Concomitant Transcatheter Aortic Valve Implantation and Off-pump Coronary Artery Bypass Grafting in Management of Severe Symptomatic Aortic Stenosis and Coronary Artery Disease
NCT04525339 ·Status: UNKNOWN
-
Supra-Annular vs. Annular ValvEs for Small Annuli
NCT04372381 ·Status: UNKNOWN ·Phase: NA
-
Changes of Ascending Aortic Diameter in Patients Undergoing Transcatheter Aortic Valve Replacement
NCT05739253 ·Status: RECRUITING
-
Portico Valve-in-Valve Retrospective Registry
NCT05002088 ·Status: COMPLETED
-
Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients
NCT02701283 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA