Trial Outcomes & Findings for Assessment of Two New Electronic Cigarettes in Cigarette Smokers (NCT NCT03435562)
NCT ID: NCT03435562
Last Updated: 2020-08-03
Results Overview
Change in plasma nicotine level
COMPLETED
NA
22 participants
Blood will be taken 4 times in each session: at baseline, 5 min after the start of a 10-puff product use, and then before and after an approximately 1-hour ad lib use period.
2020-08-03
Participant Flow
Participant milestones
| Measure |
Electronic Cigarette vs Own Brand Use
Participants will come in for three session. During one session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (the session will be approximately 3 hours). During one session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (the session will be approximately 3 hours). During one session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (the session will be approximately 3 hours). The order of the sessions will be determined randomly and data about session will not be recorded or used in the analysis.
|
|---|---|
|
Overall Study
STARTED
|
22
|
|
Overall Study
COMPLETED
|
18
|
|
Overall Study
NOT COMPLETED
|
4
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Assessment of Two New Electronic Cigarettes in Cigarette Smokers
Baseline characteristics by cohort
| Measure |
Electronic Cigarette vs Own Brand Use
n=18 Participants
Participants will come in for three session. During one session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (the session will be approximately 3 hours). During one session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (the session will be approximately 3 hours). During one session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (the session will be approximately 3 hours). The order of the sessions will be determined randomly and data about session will not be recorded or used in the analysis.
|
|---|---|
|
Age, Continuous
|
36.8 years
STANDARD_DEVIATION 9.3 • n=99 Participants
|
|
Sex: Female, Male
Female
|
5 Participants
n=99 Participants
|
|
Sex: Female, Male
Male
|
13 Participants
n=99 Participants
|
|
Ethnicity (NIH/OMB)
Hispanic or Latino
|
1 Participants
n=99 Participants
|
|
Ethnicity (NIH/OMB)
Not Hispanic or Latino
|
15 Participants
n=99 Participants
|
|
Ethnicity (NIH/OMB)
Unknown or Not Reported
|
2 Participants
n=99 Participants
|
|
Race (NIH/OMB)
American Indian or Alaska Native
|
0 Participants
n=99 Participants
|
|
Race (NIH/OMB)
Asian
|
0 Participants
n=99 Participants
|
|
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
|
0 Participants
n=99 Participants
|
|
Race (NIH/OMB)
Black or African American
|
7 Participants
n=99 Participants
|
|
Race (NIH/OMB)
White
|
8 Participants
n=99 Participants
|
|
Race (NIH/OMB)
More than one race
|
2 Participants
n=99 Participants
|
|
Race (NIH/OMB)
Unknown or Not Reported
|
1 Participants
n=99 Participants
|
PRIMARY outcome
Timeframe: Blood will be taken 4 times in each session: at baseline, 5 min after the start of a 10-puff product use, and then before and after an approximately 1-hour ad lib use period.Population: One participant was missing a sample so data was only available for 17 participants for these analyses.
Change in plasma nicotine level
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=17 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=17 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=17 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Change in Plasma Nicotine
Post puff bout
|
7.62 ng/ml
Standard Deviation 4.86
|
10.65 ng/ml
Standard Deviation 6.20
|
18.31 ng/ml
Standard Deviation 11.39
|
|
Change in Plasma Nicotine
Post ad lib
|
7.19 ng/ml
Standard Deviation 8.32
|
5.97 ng/ml
Standard Deviation 7.70
|
12.23 ng/ml
Standard Deviation 9.26
|
SECONDARY outcome
Timeframe: Carbon monoxide levels will be assessed before and after product use in each approximately 4-hr session: at baseline, 5 min after the end of a 10-puff product use, and then before and after an approximately 1-hour ad lib use period.Carbon monoxide levels (in parts per mission)
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Carbon Monoxide Levels
Pre puff bout
|
5.2 Parts per mission
Standard Deviation 2.4
|
5.5 Parts per mission
Standard Deviation 2.4
|
5.3 Parts per mission
Standard Deviation 2.0
|
|
Carbon Monoxide Levels
Post puff bout
|
8.7 Parts per mission
Standard Deviation 2.5
|
5.1 Parts per mission
Standard Deviation 2.3
|
4.9 Parts per mission
Standard Deviation 1.8
|
|
Carbon Monoxide Levels
Pre ad lib
|
8.8 Parts per mission
Standard Deviation 2.8
|
5.3 Parts per mission
Standard Deviation 2.4
|
4.6 Parts per mission
Standard Deviation 1.8
|
|
Carbon Monoxide Levels
Post ad lib
|
16.6 Parts per mission
Standard Deviation 7.0
|
4.7 Parts per mission
Standard Deviation 1.9
|
4.3 Parts per mission
Standard Deviation 1.4
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use reduces the intention to smoke a cigarette, and consists of 5 items that are scored 0 - 7, in which participants clicked seven discrete ratings from 'not at all' to 'extremely'. The items are summed and scores range from 0 to 30 with higher scores indicating higher craving for a cigarette.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Tiffany-Drobes Questionnaire of Smoking Urges - Factor 1
Pre puff bout
|
24.8 score on a scale
Standard Deviation 8.2
|
24.7 score on a scale
Standard Deviation 7.5
|
25.1 score on a scale
Standard Deviation 8.2
|
|
Tiffany-Drobes Questionnaire of Smoking Urges - Factor 1
Post puff bout
|
13.2 score on a scale
Standard Deviation 10.7
|
20.1 score on a scale
Standard Deviation 9.3
|
16.0 score on a scale
Standard Deviation 9.3
|
|
Tiffany-Drobes Questionnaire of Smoking Urges - Factor 1
Pre ad lib
|
21.2 score on a scale
Standard Deviation 8.9
|
21.7 score on a scale
Standard Deviation 9.3
|
20.4 score on a scale
Standard Deviation 8.5
|
|
Tiffany-Drobes Questionnaire of Smoking Urges - Factor 1
Post ad lib
|
11.5 score on a scale
Standard Deviation 10.2
|
17.8 score on a scale
Standard Deviation 10.6
|
14.4 score on a scale
Standard Deviation 9.7
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use reduces the intention to smoke a cigarette, and consists of 4 items that are scored 0 - 7, in which participants clicked seven discrete ratings from 'not at all' to 'extremely'. The items are summed and scores range from 0 to 24 with higher scores indicating higher craving for a cigarette.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Tiffany-Drobes Questionnaire of Smoking Urges - Factor 2
Pre puff bout
|
11.7 score on a scale
Standard Deviation 8.3
|
10.3 score on a scale
Standard Deviation 8.3
|
12.5 score on a scale
Standard Deviation 8.4
|
|
Tiffany-Drobes Questionnaire of Smoking Urges - Factor 2
Post puff bout
|
6.9 score on a scale
Standard Deviation 7.4
|
8.1 score on a scale
Standard Deviation 7.8
|
6.6 score on a scale
Standard Deviation 7.8
|
|
Tiffany-Drobes Questionnaire of Smoking Urges - Factor 2
Pre ad lib
|
9.7 score on a scale
Standard Deviation 7.4
|
9.5 score on a scale
Standard Deviation 7.5
|
9.1 score on a scale
Standard Deviation 8.6
|
|
Tiffany-Drobes Questionnaire of Smoking Urges - Factor 2
Post ad lib
|
5.5 score on a scale
Standard Deviation 7.6
|
6.5 score on a scale
Standard Deviation 7.2
|
6.6 score on a scale
Standard Deviation 8.9
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use affects on anxiety and consists of 1 item scored 0 - 100 with 0 being not at all and 100 being extremely.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Hughes-Hatsukami Questionnaire - Anxious
Pre puff bout
|
46.3 score on a scale
Standard Deviation 32.5
|
42.8 score on a scale
Standard Deviation 31.9
|
44.5 score on a scale
Standard Deviation 34.9
|
|
Hughes-Hatsukami Questionnaire - Anxious
Post puff bout
|
24.8 score on a scale
Standard Deviation 30.6
|
24.4 score on a scale
Standard Deviation 31.8
|
28.4 score on a scale
Standard Deviation 33.9
|
|
Hughes-Hatsukami Questionnaire - Anxious
Pre ad lib
|
22.1 score on a scale
Standard Deviation 22.8
|
20.8 score on a scale
Standard Deviation 30.1
|
17.2 score on a scale
Standard Deviation 27.2
|
|
Hughes-Hatsukami Questionnaire - Anxious
Post ad lib
|
19.4 score on a scale
Standard Deviation 27.5
|
20.4 score on a scale
Standard Deviation 27
|
28.4 score on a scale
Standard Deviation 32.6
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use affects on craving a cigarette and consists of 1 item scored 0 - 100 with 0 being not at all and 100 being extremely.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Hughes-Hatsukami Questionnaire - Craving
Pre puff bout
|
75.2 points on a scale
Standard Deviation 30.7
|
70.5 points on a scale
Standard Deviation 30.9
|
73.5 points on a scale
Standard Deviation 33.5
|
|
Hughes-Hatsukami Questionnaire - Craving
Post puff bout
|
34.9 points on a scale
Standard Deviation 35
|
49.3 points on a scale
Standard Deviation 36.0
|
42.9 points on a scale
Standard Deviation 31.8
|
|
Hughes-Hatsukami Questionnaire - Craving
Pre ad lib
|
55.2 points on a scale
Standard Deviation 30.5
|
54.0 points on a scale
Standard Deviation 38
|
53.8 points on a scale
Standard Deviation 29.9
|
|
Hughes-Hatsukami Questionnaire - Craving
Post ad lib
|
25.5 points on a scale
Standard Deviation 29.2
|
53.9 points on a scale
Standard Deviation 34.9
|
36.2 points on a scale
Standard Deviation 32.1
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use affects on depression and consists of 1 item scored 0 - 100 with 0 being not at all and 100 being extremely.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Hughes-Hatsukami Questionnaire - Depression
Pre puff bout
|
21.4 points on a scale
Standard Deviation 28.3
|
15.1 points on a scale
Standard Deviation 20.9
|
20.5 points on a scale
Standard Deviation 26.1
|
|
Hughes-Hatsukami Questionnaire - Depression
Post puff bout
|
9.8 points on a scale
Standard Deviation 16.8
|
8.8 points on a scale
Standard Deviation 16.6
|
15.1 points on a scale
Standard Deviation 22.6
|
|
Hughes-Hatsukami Questionnaire - Depression
Pre ad lib
|
11.5 points on a scale
Standard Deviation 21.5
|
8.1 points on a scale
Standard Deviation 17.0
|
10.6 points on a scale
Standard Deviation 20.1
|
|
Hughes-Hatsukami Questionnaire - Depression
Post ad lib
|
8.8 points on a scale
Standard Deviation 13.6
|
8.2 points on a scale
Standard Deviation 16.3
|
11.5 points on a scale
Standard Deviation 21.7
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use affects having difficulty concentrating and consists of 1 item scored 0 - 100 with 0 being not at all and 100 being extremely.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Hughes-Hatsukami Questionnaire - Difficulty Concentrating
Pre puff bout
|
28.2 points on a scale
Standard Deviation 26.4
|
37.6 points on a scale
Standard Deviation 30.1
|
30.0 points on a scale
Standard Deviation 31.9
|
|
Hughes-Hatsukami Questionnaire - Difficulty Concentrating
Post puff bout
|
18.5 points on a scale
Standard Deviation 20.4
|
17.3 points on a scale
Standard Deviation 19.9
|
24.4 points on a scale
Standard Deviation 29.9
|
|
Hughes-Hatsukami Questionnaire - Difficulty Concentrating
Pre ad lib
|
18.1 points on a scale
Standard Deviation 20.8
|
15.5 points on a scale
Standard Deviation 22.5
|
16.8 points on a scale
Standard Deviation 20.6
|
|
Hughes-Hatsukami Questionnaire - Difficulty Concentrating
Post ad lib
|
10.4 points on a scale
Standard Deviation 18.1
|
17.8 points on a scale
Standard Deviation 25.8
|
18.9 points on a scale
Standard Deviation 27.0
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use affects feeling drowsy and consists of 1 item scored 0 - 100 with 0 being not at all and 100 being extremely.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Hughes-Hatsukami Questionnaire - Drowsy
Pre puff bout
|
35.2 points on a scale
Standard Deviation 25
|
33.8 points on a scale
Standard Deviation 28.2
|
31.9 points on a scale
Standard Deviation 33.9
|
|
Hughes-Hatsukami Questionnaire - Drowsy
Post puff bout
|
28.7 points on a scale
Standard Deviation 26.1
|
21.4 points on a scale
Standard Deviation 24.6
|
29.4 points on a scale
Standard Deviation 26.5
|
|
Hughes-Hatsukami Questionnaire - Drowsy
Pre ad lib
|
24.9 points on a scale
Standard Deviation 24.3
|
25.9 points on a scale
Standard Deviation 31.1
|
23.4 points on a scale
Standard Deviation 24.6
|
|
Hughes-Hatsukami Questionnaire - Drowsy
Post ad lib
|
23.4 points on a scale
Standard Deviation 26.9
|
25.3 points on a scale
Standard Deviation 27.0
|
27.4 points on a scale
Standard Deviation 29.8
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use affects reducing hunger and consists of 1 item scored 0 - 100 with 0 being not at all and 100 being extremely.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Hughes-Hatsukami Questionnaire - Hunger
Pre puff bout
|
39.9 points on a scale
Standard Deviation 22.7
|
43.2 points on a scale
Standard Deviation 29.8
|
43.0 points on a scale
Standard Deviation 35.5
|
|
Hughes-Hatsukami Questionnaire - Hunger
Post puff bout
|
31.9 points on a scale
Standard Deviation 24.4
|
35.6 points on a scale
Standard Deviation 33.3
|
30.2 points on a scale
Standard Deviation 25.5
|
|
Hughes-Hatsukami Questionnaire - Hunger
Pre ad lib
|
34.8 points on a scale
Standard Deviation 25.9
|
39.5 points on a scale
Standard Deviation 35.9
|
37.7 points on a scale
Standard Deviation 29.0
|
|
Hughes-Hatsukami Questionnaire - Hunger
Post ad lib
|
39.8 points on a scale
Standard Deviation 30.7
|
58.4 points on a scale
Standard Deviation 29.0
|
53.2 points on a scale
Standard Deviation 31.9
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use affects feeling impatient and consists of 1 item scored 0 - 100 with 0 being not at all and 100 being extremely.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Hughes-Hatsukami Questionnaire - Impatient
Pre puff bout
|
42.1 points on a scale
Standard Deviation 28.3
|
41.0 points on a scale
Standard Deviation 30.6
|
51.4 points on a scale
Standard Deviation 31.0
|
|
Hughes-Hatsukami Questionnaire - Impatient
Post puff bout
|
23.9 points on a scale
Standard Deviation 27.3
|
25.9 points on a scale
Standard Deviation 31.0
|
25.1 points on a scale
Standard Deviation 30.9
|
|
Hughes-Hatsukami Questionnaire - Impatient
Pre ad lib
|
26.9 points on a scale
Standard Deviation 29.3
|
31.4 points on a scale
Standard Deviation 28.9
|
29.7 points on a scale
Standard Deviation 30.3
|
|
Hughes-Hatsukami Questionnaire - Impatient
Post ad lib
|
25.5 points on a scale
Standard Deviation 28.2
|
31.8 points on a scale
Standard Deviation 30.5
|
27.2 points on a scale
Standard Deviation 27.0
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use affects feeling irritable and consists of 1 item scored 0 - 100 with 0 being not at all and 100 being extremely.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Hughes-Hatsukami Questionnaire - Irritable
Pre puff bout
|
37.4 points on a scale
Standard Deviation 31.0
|
34.5 points on a scale
Standard Deviation 31.1
|
38.7 points on a scale
Standard Deviation 33.3
|
|
Hughes-Hatsukami Questionnaire - Irritable
Post puff bout
|
14.9 points on a scale
Standard Deviation 17.2
|
18.4 points on a scale
Standard Deviation 22.1
|
19.8 points on a scale
Standard Deviation 26.3
|
|
Hughes-Hatsukami Questionnaire - Irritable
Pre ad lib
|
14.1 points on a scale
Standard Deviation 16.0
|
15.4 points on a scale
Standard Deviation 22.3
|
16.8 points on a scale
Standard Deviation 21.0
|
|
Hughes-Hatsukami Questionnaire - Irritable
Post ad lib
|
14.6 points on a scale
Standard Deviation 22.0
|
15.1 points on a scale
Standard Deviation 26.4
|
16.8 points on a scale
Standard Deviation 24.1
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use affects feeling restless and consists of 1 item scored 0 - 100 with 0 being not at all and 100 being extremely.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Hughes-Hatsukami Questionnaire - Restless
Pre puff bout
|
40.8 points on a scale
Standard Deviation 29.4
|
30.2 points on a scale
Standard Deviation 25.5
|
28.9 points on a scale
Standard Deviation 31.8
|
|
Hughes-Hatsukami Questionnaire - Restless
Post puff bout
|
19.7 points on a scale
Standard Deviation 24.8
|
26.9 points on a scale
Standard Deviation 25.9
|
19.7 points on a scale
Standard Deviation 24.6
|
|
Hughes-Hatsukami Questionnaire - Restless
Pre ad lib
|
27.7 points on a scale
Standard Deviation 27.2
|
17.9 points on a scale
Standard Deviation 25.7
|
33.4 points on a scale
Standard Deviation 31.4
|
|
Hughes-Hatsukami Questionnaire - Restless
Post ad lib
|
21.5 points on a scale
Standard Deviation 28.1
|
24.7 points on a scale
Standard Deviation 27.6
|
27.1 points on a scale
Standard Deviation 28.4
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use affects having desire for sweets and consists of 1 item scored 0 - 100 with 0 being not at all and 100 being extremely.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Hughes-Hatsukami Questionnaire - Desire for Sweets
Pre puff bout
|
24.2 points on a scale
Standard Deviation 30.7
|
27.4 points on a scale
Standard Deviation 33.3
|
24.8 points on a scale
Standard Deviation 28.3
|
|
Hughes-Hatsukami Questionnaire - Desire for Sweets
Post puff bout
|
16.8 points on a scale
Standard Deviation 21.4
|
20.3 points on a scale
Standard Deviation 27.2
|
16.4 points on a scale
Standard Deviation 25.7
|
|
Hughes-Hatsukami Questionnaire - Desire for Sweets
Pre ad lib
|
18.8 points on a scale
Standard Deviation 25.8
|
20.7 points on a scale
Standard Deviation 28.1
|
23.8 points on a scale
Standard Deviation 27.9
|
|
Hughes-Hatsukami Questionnaire - Desire for Sweets
Post ad lib
|
17.9 points on a scale
Standard Deviation 21.3
|
17.4 points on a scale
Standard Deviation 24.0
|
20.5 points on a scale
Standard Deviation 27.0
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.This scale is used to assess the extent to which product use affects having the urge to smoke and consists of 1 item scored 0 - 100 with 0 being not at all and 100 being extremely.
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Hughes-Hatsukami Questionnaire - Urge to Smoke
Pre puff bout
|
76.5 points on a scale
Standard Deviation 25.2
|
67.2 points on a scale
Standard Deviation 29.9
|
74.7 points on a scale
Standard Deviation 31.5
|
|
Hughes-Hatsukami Questionnaire - Urge to Smoke
Post puff bout
|
39.2 points on a scale
Standard Deviation 34.8
|
48.8 points on a scale
Standard Deviation 31.9
|
46.2 points on a scale
Standard Deviation 29.5
|
|
Hughes-Hatsukami Questionnaire - Urge to Smoke
Pre ad lib
|
54.4 points on a scale
Standard Deviation 27.6
|
46.9 points on a scale
Standard Deviation 33.3
|
56.9 points on a scale
Standard Deviation 27.8
|
|
Hughes-Hatsukami Questionnaire - Urge to Smoke
Post ad lib
|
24.9 points on a scale
Standard Deviation 25.7
|
50.0 points on a scale
Standard Deviation 31.1
|
38 points on a scale
Standard Deviation 31.8
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.One question is used to assess how much product use makes participants feel awake, and is scored 0 (not at all) to 100 (extremely).
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Direct Effects of Nicotine Questionnaire - Awake
Post puff bout
|
40.9 score on a question
Standard Deviation 31.7
|
33.8 score on a question
Standard Deviation 29.9
|
36.5 score on a question
Standard Deviation 30.6
|
|
Direct Effects of Nicotine Questionnaire - Awake
Post ad lib
|
45.1 score on a question
Standard Deviation 31.3
|
28.1 score on a question
Standard Deviation 29.6
|
34.5 score on a question
Standard Deviation 27.4
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.One question is used to assess how much product use makes participants feel calm, and is scored 0 (not at all) to 100 (extremely).
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Direct Effects of Nicotine Questionnaire - Calm
Post puff bout
|
60.9 score on a question
Standard Deviation 36
|
47.9 score on a question
Standard Deviation 31.9
|
54.4 score on a question
Standard Deviation 31.5
|
|
Direct Effects of Nicotine Questionnaire - Calm
Post ad lib
|
60.7 score on a question
Standard Deviation 35.3
|
46.6 score on a question
Standard Deviation 29.7
|
43.2 score on a question
Standard Deviation 34.5
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.One question is used to assess how much product use helps participants concentrate, and is scored 0 (not at all) to 100 (extremely).
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Direct Effects of Nicotine Questionnaire - Concentrate
Post puff bout
|
34.8 score on a question
Standard Deviation 30.8
|
24.5 score on a question
Standard Deviation 26.3
|
38.5 score on a question
Standard Deviation 33.7
|
|
Direct Effects of Nicotine Questionnaire - Concentrate
Post ad lib
|
42.0 score on a question
Standard Deviation 34.3
|
27.5 score on a question
Standard Deviation 26.3
|
27.8 score on a question
Standard Deviation 27.1
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.One question is used to assess how much product use makes participants feel dizzy, and is scored 0 (not at all) to 100 (extremely).
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Direct Effects of Nicotine Questionnaire - Dizzy
Post puff bout
|
40.7 score on a question
Standard Deviation 33.4
|
33.7 score on a question
Standard Deviation 33.5
|
36.4 score on a question
Standard Deviation 33.7
|
|
Direct Effects of Nicotine Questionnaire - Dizzy
Post ad lib
|
30.1 score on a question
Standard Deviation 36.2
|
19.4 score on a question
Standard Deviation 27.2
|
26.9 score on a question
Standard Deviation 25.8
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.One question is used to assess how much product use reduces feeling of hunger, and is scored 0 (not at all) to 100 (extremely).
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Direct Effects of Nicotine Questionnaire - Reduce Hunger
Post puff bout
|
41.9 score on a question
Standard Deviation 29.9
|
35.2 score on a question
Standard Deviation 27.4
|
29.2 score on a question
Standard Deviation 28.8
|
|
Direct Effects of Nicotine Questionnaire - Reduce Hunger
Post ad lib
|
33.0 score on a question
Standard Deviation 27.7
|
37.1 score on a question
Standard Deviation 31.0
|
34.3 score on a question
Standard Deviation 26.1
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 4 times in each each approximately 4-hr session: before any product use, 10 minutes after the start of a 10-puff use bout, and then before and after an approximately 1-hour ad lib use period.One question is used to assess how much product use makes participants feel sick, and is scored 0 (not at all) to 100 (extremely).
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Direct Effects of Nicotine Questionnaire - Sick
Post puff bout
|
4.1 score on a question
Standard Deviation 7.5
|
8.1 score on a question
Standard Deviation 14.2
|
9.5 score on a question
Standard Deviation 19.0
|
|
Direct Effects of Nicotine Questionnaire - Sick
Post ad lib
|
2.6 score on a question
Standard Deviation 5.2
|
7.8 score on a question
Standard Deviation 14.4
|
10.5 score on a question
Standard Deviation 16.8
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 2 times in each each approximately 4-hr session: 10 minutes after the start of a 10-puff use bout, and then after an approxiamtely 1-hour ad lib use period.A single question is used to assess if product use felt pleasant, and is scored 0 (not at all) to 100 (extremely).
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Direct Effects of Product Use Questionnaire - Pleasant
Post puff bout
|
81.4 score on a question
Standard Deviation 29.8
|
50.4 score on a question
Standard Deviation 31.6
|
58.8 score on a question
Standard Deviation 36.0
|
|
Direct Effects of Product Use Questionnaire - Pleasant
Post ad lib
|
81.9 score on a question
Standard Deviation 24.9
|
50.6 score on a question
Standard Deviation 31.2
|
58.9 score on a question
Standard Deviation 34.4
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 2 times in each each approximately 4-hr session: 10 minutes after the start of a 10-puff use bout, and then after an approxiamtely 1-hour ad lib use period.A single question is used to assess if product use tasted good, and is scored 0 (not at all) to 100 (extremely).
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Direct Effects of Product Use Questionnaire - Taste Good
Post puff bout
|
77.7 score on a question
Standard Deviation 29.5
|
50.5 score on a question
Standard Deviation 32.6
|
54.6 score on a question
Standard Deviation 36.4
|
|
Direct Effects of Product Use Questionnaire - Taste Good
Post ad lib
|
74.0 score on a question
Standard Deviation 32.1
|
51.2 score on a question
Standard Deviation 30.7
|
49.8 score on a question
Standard Deviation 35.7
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 2 times in each each approximately 4-hr session: 10 minutes after the start of a 10-puff use bout, and then after an approxiamtely 1-hour ad lib use period.A single question is used to assess if product use felt satisfying, and is scored 0 (not at all) to 100 (extremely).
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Direct Effects of Product Use Questionnaire - Satisfying
Post puff bout
|
84.3 score on a question
Standard Deviation 24.4
|
47.0 score on a question
Standard Deviation 33.2
|
58.8 score on a question
Standard Deviation 30.9
|
|
Direct Effects of Product Use Questionnaire - Satisfying
Post ad lib
|
83.7 score on a question
Standard Deviation 24.5
|
46.5 score on a question
Standard Deviation 31.5
|
58.8 score on a question
Standard Deviation 33.3
|
SECONDARY outcome
Timeframe: Questionnaire will be administered 2 times in each each approximately 4-hr session: 10 minutes after the start of a 10-puff use bout, and then after an approxiamtely 1-hour ad lib use period.A single question is used to assess if product use made them want to use the product again right now, and is scored 0 (not at all) to 100 (extremely).
Outcome measures
| Measure |
JUUL Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with JUUL, and then a 90-minute ad lib product use bout with JUUL (each session will be approximately 3 hours).
JUUL electronic cigarette: Effects of JUUL electronic cigarette use.
|
IQOS Electronic Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with IQOS, and then a 90-minute ad lib product use bout with IQOS (each session will be approximately 3 hours).
IQOS electronic cigarette: Effects of IQOS electronic cigarette use.
|
Own Brand Cigarette Use
n=18 Participants
During each session, participants will first complete a 10-puff product use bout with their own brand cigarettes, and then a 90-minute ad lib product use bout with their own brand cigarette (each session will be approximately 3 hours).
Own Brand cigarette: Effects of own brand cigarette use.
|
|---|---|---|---|
|
Direct Effects of Product Use Questionnaire - Smoke Right Now
Post puff bout
|
62.8 score on a question
Standard Deviation 37.7
|
45.4 score on a question
Standard Deviation 32.7
|
47.2 score on a question
Standard Deviation 39.1
|
|
Direct Effects of Product Use Questionnaire - Smoke Right Now
Post ad lib
|
44.1 score on a question
Standard Deviation 37.7
|
35.5 score on a question
Standard Deviation 29.1
|
37.5 score on a question
Standard Deviation 33.5
|
OTHER_PRE_SPECIFIED outcome
Timeframe: Heat rate will be measured from baseline continuously throughout each each approximately 4-hr sessionChange in heart rate, measured in beats per minute
Outcome measures
Outcome data not reported
OTHER_PRE_SPECIFIED outcome
Timeframe: Blood pressure will be measured from baseline continuously throughout each approximately 4-hr sessionChange in blood pressure, measured in mm/hg
Outcome measures
Outcome data not reported
Adverse Events
JUUL Electronic Cigarette Use
IQOS Electronic Cigarette Use
Own Brand Cigarette Use
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place