An Innovative Approach for Uniblocker Intubation
NCT03392818 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 90
Last updated 2018-01-09
Summary
To measure the distance between the upper edge of the thyroid cartilage to the upper edge of the sternum add the distance from the upper edge of the sternum to the carina was calculated according to the chest CT scans as a guide to the placement of Uniblocker without the aid of FOB.
Conditions
- Therapeutic Procedural Complication
Interventions
- OTHER
-
The measured distance
To measure the distance between the upper edge of the thyroid cartilage to the upper edge of the sternum add the distance from the upper edge of the sternum to the carina calculated according to the chest CT scans as a guide to the placement of Uniblocker without the aid of Fiberoptic bronchoscope.
- OTHER
-
formula
Calculate the depth of intubation according to the formula of 0.1977\* patient's height - 4.2423
- DEVICE
-
Fiberoptic bronchoscope
The intubation of Uniblocker under the guidance of Fiberoptic bronchoscope
Sponsors & Collaborators
-
The First Hospital of Qinhuangdao
lead OTHER_GOV
Principal Investigators
-
Ximing Qi · The First Hospital of Qinhuangdao
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- TRIPLE
- Model
- FACTORIAL
Eligibility
- Min Age
- 18 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2018-01-07
- Primary Completion
- 2018-05-31
- Completion
- 2018-06-30
Countries
- China
Study Locations
More Related Trials
-
Cricothyroidotomy Training for Physicians Outcomes Study
NCT03238950 ·Status: WITHDRAWN ·Phase: NA
-
The Manikin Study of Chest Compression With One Accelerometer Feedback Device
NCT02073539 ·Status: COMPLETED ·Phase: NA
-
Hypoxic Preconditioning on Patients
NCT02966418 ·Status: COMPLETED ·Phase: NA
-
To Compare Predictive Power of End-tidal Carbon Dioxide Between Different Time Line During Resuscitation
NCT03345888 ·Status: UNKNOWN
-
Pre-oxygenation With Real Time End-tidal Oxygen Measurements Versus Single Breath Measurements
NCT03840486 ·Status: COMPLETED ·Phase: PHASE4
-
Apneic Oxygenation Via Nasal Cannulae Prevents Arterial Hypoxemia
NCT00782977 ·Status: COMPLETED ·Phase: NA
-
Blood Isoflurane Concentration and the Oxygenator
NCT03146949 ·Status: COMPLETED ·Phase: NA
-
Myocardial Injury and Intraoperative Tissue Oximetry in Patients Undergoing Spine Surgery
NCT03518372 ·Status: COMPLETED
-
Respiratory Parameters Using Advanced Airways During In-hospital Cardiac Arrest
NCT06580652 ·Status: RECRUITING
-
Carotid Ultrasound Under Pulsed-wave Doppler Mode to Check the Pulse in Cardiopulmonary Arrest Patients.
NCT04790396 ·Status: ACTIVE_NOT_RECRUITING
-
Calibration and Validation of Masimo's O3 Regional Oximetry Device in Neonates, Infants and Children
NCT03123354 ·Status: COMPLETED ·Phase: NA
-
Impact of Continuous Monitoring of PtC02 on Ventilatory Weaning in Neuro-injured Patients
NCT04819984 ·Status: UNKNOWN ·Phase: NA
-
Appropriate Number of Endotracheal Intubation Experience for CPR
NCT03423745 ·Status: COMPLETED
-
The Clinical Value of Applying TOF and TcPO2 to Guide Elderly Patients Extubation
NCT02327910 ·Status: UNKNOWN ·Phase: NA
-
Feasibility of End-tidal Oxygen Concentration Monitoring During Preoxygenation for Intubation in the Intensive Care Unit.
NCT05409573 ·Status: RECRUITING ·Phase: NA
-
The Critical Threshold of Pulse Oximetry Plethysmographic Waveform Parameters in High Quality CPR
NCT03754946 ·Status: UNKNOWN
-
Assessment of Preoxygenation Strategies in the Prehospital Environment
NCT02694705 ·Status: COMPLETED ·Phase: NA
-
Goal Directed Numeric Coaching as a Means of Preoxygenation
NCT05978635 ·Status: COMPLETED ·Phase: NA
-
Automatic Oxygen Administration After Major Abdominal and Thoracic Surgery
NCT02546830 ·Status: COMPLETED ·Phase: NA
-
A Study of Agreement Between Oxygen Saturation Measured by Two Probes in Infants on the Neonatal Unit
NCT05065229 ·Status: COMPLETED ·Phase: NA
-
Enhancing Operability in a Hypobaric Hypoxic Environment With a Small Oxygen Storage System
NCT03365128 ·Status: WITHDRAWN
-
Study of the Functional State of the Body of Medical Workers in the Intensive Care Unit for Newborns
NCT05491148 ·Status: COMPLETED
-
Accuracy of Continuous SpO2 Measurement in Adults
NCT01183338 ·Status: WITHDRAWN
-
Waveform Capnography Compared to Colorimetric Carbon Dioxide Detection During Tracheal Intubation of Critically Ill Adults
NCT06934876 ·Status: RECRUITING
-
Monitoring and Optimization of Cerebral Perfusion Pressure in Post-cardiac Arrest Patients: a Pilot Study
NCT06601842 ·Status: RECRUITING ·Phase: NA