The Relationship Between Macular OCTA and GCIPL and Their Combinational Index Using AI
NCT03369886 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 206
Last updated 2017-12-29
Summary
Macular GCIPLT and vessel density will be measured with Spectralis optical coherence tomography and Topcon swept-source OCT respectively. Linear, quadratic and exponential regression models will be used to investigate relationship between GCIPLT and vessel density. Multilayer neural network will bel used to make single combined parameter and the diagnostic performance will be also compared.
Conditions
- Angiography
- Glaucoma, Open-Angle
Interventions
- DIAGNOSTIC_TEST
-
Optical Coherence Tomography Angiography (OCTA)
The images will be obtained using a commercial swept-source OCT (SS-OCT) device (DRI OCT Atlantis; Topcon, Tokyo, Japan). SS-OCT uses infrared light, wavelength of 1050 nm which is longer than conventional SD-OCT, at 100,000 A-scans per second. This longer infrared light source has advantages of deep signal penetration through the retina and choroid. Its axial and transversal resolution is 7 and 20 μm in tissue, respectively. Volumetric OCT scans were taken from 6 × 6 mm cubes. Each cube consists of 320 clusters of 4 repeated B-scans centered on the fovea. Moving objects (mostly blood flows) are detected by measuring intensity fluctuations from these repeatedly scanned OCT images. Automated segmentation was performed by OCT software to separate each layer of the retina. The en-face images of the superficial capillary network were derived from an en-face slab, ranged from the internal limiting membrane (ILM) to the inner border of the inner nuclear layer (INL).
Sponsors & Collaborators
-
Pusan National University Hospital
lead OTHER
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 19 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2017-09-25
- Primary Completion
- 2018-08-31
- Completion
- 2018-08-31
Countries
- South Korea
Study Locations
More Related Trials
-
Investigation of the Regulation of Retinal and Choroidal Blood Vessels in Various AL Based on WF SS-OCTA Detection With Changes in Body Position
NCT06587776 ·Status: NOT_YET_RECRUITING
-
Quantitatively Analysis of Fundus Structure Characteristics in Glaucoma Following Congenital Cataract Surgery
NCT05446077 ·Status: COMPLETED
-
Optical Coherence Tomography Angiography Criteria Of The Choroidal Neovascular Membrane In Wet Age Related Macular Degeneration And In Pathological Myopia (Comparative Study).
NCT05562336 ·Status: UNKNOWN
-
OCTA Changes in Choroidal Neovascularization in High Myopia
NCT06357559 ·Status: NOT_YET_RECRUITING
-
Measurment of Optic Disc Parameters, RNFL Thickness and Ganglion Cell Complex in Myopic, Hypermetropic and Emmetropic Patients Using OCT and Axial Length Measurments
NCT07241806 ·Status: NOT_YET_RECRUITING
-
Efficacy of Retinal Nerve Fiber Layer (RNFL) / Retinal Thickness Ratio by Cirrus OCT Utilizing Spectral -Domain Technology as a Diagnostic Predictor of Glaucoma
NCT00772993 ·Status: UNKNOWN
-
OCTA (Optical Coherence Angiography Tomography) Versus Structural OCT(Optical Coherence Tomography) in Neovascular AMD (Age Macular Degeneration)
NCT03939195 ·Status: COMPLETED
-
Comparison of Retinal Nerve Fiber Layer (RNFL) Thickness Measurements by Time-Domain and Spectral-Domain OCT In Glaucoma Patients
NCT00773877 ·Status: UNKNOWN
-
Study to Compare Kowa OCT Bi-μ and the Optovue iVue 100
NCT03505567 ·Status: COMPLETED ·Phase: NA
-
Multi-modal Intelligent Diagnosis System for Multiple Ophthalmic Diseases
NCT07143851 ·Status: NOT_YET_RECRUITING
-
Artificial Intelligence (AI) - Assisted Visual Impairment Screening Model: Community-based Implementation and Evaluation of Performance, Feasibility and Costs.
NCT06877988 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
High-throughput Large-model-based AI-assisted Diagnosis Using OCT
NCT07249307 ·Status: NOT_YET_RECRUITING
-
Application and Safety Evaluation of 3D Visualization System in Microsurgical Training
NCT05865860 ·Status: UNKNOWN
-
Early Vision Screening in High-risk Children
NCT02678468 ·Status: UNKNOWN
-
OCTA Insights in CNVM, Morphological Characteristics and Correlation With Structural OCT.
NCT05055973 ·Status: UNKNOWN
-
Investigating the Retardation Effect of OCTA-Guided Targeted Photocoagulation on the Progression of Non-Perfusion Areas in Diabetic Retinopathy Patients
NCT06821633 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Ophthalmic AI-Assisted Medical Decision-Making
NCT06755060 ·Status: RECRUITING ·Phase: NA
-
Retinal Nerve Fiber Layer Thickness and Macular Thickness in Myopia, Hyperopia and Emmetropia : An OCT Study
NCT05486741 ·Status: UNKNOWN
-
Evaluation of Optical Coherence Tomography.
NCT01080898 ·Status: COMPLETED
-
Comparison of Repeatability Between SS and SD-OCT for Measuring Retinal Thickness in Various Retinal Diseases
NCT03438903 ·Status: COMPLETED
-
Prospective Geometric Analysis of Ultra-Widefield OCTA Characteristics in Central Serous Chorioretinopathy Patients
NCT07347119 ·Status: NOT_YET_RECRUITING
-
Development of an Optimal Algorithm for the Management of Patients With Retinal Pigment Epithelium Detachment in Neovascular Age-related Macular Degeneration Using Artificial Intelligence
NCT05208931 ·Status: COMPLETED
-
Feasibility Study and Preliminary Application Study on Iris OCTA
NCT03631108 ·Status: UNKNOWN
-
Real-time Artificial Intelligence System for Detecting Multiple Ocular Fundus Lesions by Ultra-widefield Fundus Imaging
NCT04859634 ·Status: UNKNOWN
-
Ophthalmic Multimodal AI-Assisted Medical Decision-Making
NCT06755190 ·Status: RECRUITING