Trial Outcomes & Findings for Changes of Macular Pigment and Parameters of Eyes After YAG Laser Treatment in Cases With Capsule Opacification (NCT NCT03321253)
NCT ID: NCT03321253
Last Updated: 2019-08-07
Results Overview
Foveal and pericentral pigment optical density was measured by using color perimetry technique and recorded as log unit before Nd: YAG laser posterior capsulotomy, at 1 week, 1 month and 2 months
COMPLETED
NA
38 participants
2 months
2019-08-07
Participant Flow
Participant milestones
| Measure |
Nd: YAG Laser Posterior Capsulotomy
Posterior capsulotomy was performed by using Nd: YAG laser and macular pigment optical density, intra ocular pressure, choroidal thickness, macular thickness and anterior chamber parameters were measured before Nd: YAG laser, at 1 week, 1 month and 2 months
Nd: YAG laser posterior capsulotomy: Nd: YAG laser posterior capsulotomy
|
|---|---|
|
Overall Study
STARTED
|
38
|
|
Overall Study
COMPLETED
|
38
|
|
Overall Study
NOT COMPLETED
|
0
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Changes of Macular Pigment and Parameters of Eyes After YAG Laser Treatment in Cases With Capsule Opacification
Baseline characteristics by cohort
| Measure |
Nd: YAG Laser Posterior Capsulotomy
n=38 Participants
Posterior capsulotomy was performed by using Nd: YAG laser and macular pigment optical density, intra ocular pressure, choroidal thickness, macular thickness and anterior chamber parameters were measured before Nd: YAG laser, at 1 week, 1 month and 2 months
Nd: YAG laser posterior capsulotomy: Nd: YAG laser posterior capsulotomy
|
|---|---|
|
Age, Categorical
<=18 years
|
0 Participants
n=99 Participants
|
|
Age, Categorical
Between 18 and 65 years
|
38 Participants
n=99 Participants
|
|
Age, Categorical
>=65 years
|
0 Participants
n=99 Participants
|
|
Age, Continuous
|
55.37 years
STANDARD_DEVIATION 4.45 • n=99 Participants
|
|
Sex: Female, Male
Female
|
19 Participants
n=99 Participants
|
|
Sex: Female, Male
Male
|
19 Participants
n=99 Participants
|
|
Region of Enrollment
Turkey
|
38 participants
n=99 Participants
|
PRIMARY outcome
Timeframe: 2 monthsFoveal and pericentral pigment optical density was measured by using color perimetry technique and recorded as log unit before Nd: YAG laser posterior capsulotomy, at 1 week, 1 month and 2 months
Outcome measures
| Measure |
Nd: YAG Laser Posterior Capsulotomy
n=38 Participants
Posterior capsulotomy was performed by using Nd: YAG laser and macular pigment optical density, intra ocular pressure, choroidal thickness, macular thickness and anterior chamber parameters were measured before Nd: YAG laser, at 1 week, 1 month and 2 months
Nd: YAG laser posterior capsulotomy: Nd: YAG laser posterior capsulotomy
|
|---|---|
|
Changes of Foveal and Pericentral Pigment Optical Density (Log Unit) From Baseline at 2 Months
MPOD fovea at baseline
|
0.55 log unit
Standard Deviation 0.07
|
|
Changes of Foveal and Pericentral Pigment Optical Density (Log Unit) From Baseline at 2 Months
MPOD fovea at 1-week
|
0.52 log unit
Standard Deviation 0.08
|
|
Changes of Foveal and Pericentral Pigment Optical Density (Log Unit) From Baseline at 2 Months
MPOD fovea at 1-month
|
0.51 log unit
Standard Deviation 0.09
|
|
Changes of Foveal and Pericentral Pigment Optical Density (Log Unit) From Baseline at 2 Months
MPOD fovea at 2-month
|
0.5 log unit
Standard Deviation 0.09
|
|
Changes of Foveal and Pericentral Pigment Optical Density (Log Unit) From Baseline at 2 Months
MPOD pericentral at baseline
|
0.33 log unit
Standard Deviation 0.05
|
|
Changes of Foveal and Pericentral Pigment Optical Density (Log Unit) From Baseline at 2 Months
MPOD pericentral at 1-week
|
0.31 log unit
Standard Deviation 0.05
|
|
Changes of Foveal and Pericentral Pigment Optical Density (Log Unit) From Baseline at 2 Months
MPOD pericentral at 1-month
|
0.3 log unit
Standard Deviation 0.06
|
|
Changes of Foveal and Pericentral Pigment Optical Density (Log Unit) From Baseline at 2 Months
MPOD pericentral at 2-month
|
0.29 log unit
Standard Deviation 0.06
|
PRIMARY outcome
Timeframe: 2 monthsSubfoveal, temporal and nasal choroidal thicknesses were measured by using enhanced-deep imaging optical coherence tomography and recorded as micrometer before Nd: YAG laser posterior capsulotomy, at 1 week, at 1-month and at 2-month
Outcome measures
| Measure |
Nd: YAG Laser Posterior Capsulotomy
n=38 Participants
Posterior capsulotomy was performed by using Nd: YAG laser and macular pigment optical density, intra ocular pressure, choroidal thickness, macular thickness and anterior chamber parameters were measured before Nd: YAG laser, at 1 week, 1 month and 2 months
Nd: YAG laser posterior capsulotomy: Nd: YAG laser posterior capsulotomy
|
|---|---|
|
Changes of Subfoveal, Temporal and Nasal Choroidal Thicknesses (Micrometer) From Baseline at 2 Months
Subfoveal choroidal thickness baseline
|
276.46 micrometer
Standard Deviation 19.36
|
|
Changes of Subfoveal, Temporal and Nasal Choroidal Thicknesses (Micrometer) From Baseline at 2 Months
Subfoveal choroidal thickness at 1-week
|
276.54 micrometer
Standard Deviation 19.45
|
|
Changes of Subfoveal, Temporal and Nasal Choroidal Thicknesses (Micrometer) From Baseline at 2 Months
Subfoveal choroidal thickness at 1-month
|
276.86 micrometer
Standard Deviation 19.42
|
|
Changes of Subfoveal, Temporal and Nasal Choroidal Thicknesses (Micrometer) From Baseline at 2 Months
Subfoveal choroidal thickness at 2-month
|
276.76 micrometer
Standard Deviation 19.36
|
|
Changes of Subfoveal, Temporal and Nasal Choroidal Thicknesses (Micrometer) From Baseline at 2 Months
Temporal choroidal thickness at baseline
|
275.04 micrometer
Standard Deviation 20.59
|
|
Changes of Subfoveal, Temporal and Nasal Choroidal Thicknesses (Micrometer) From Baseline at 2 Months
Temporal choroidal thickness at 1-week
|
275.02 micrometer
Standard Deviation 20.67
|
|
Changes of Subfoveal, Temporal and Nasal Choroidal Thicknesses (Micrometer) From Baseline at 2 Months
Temporal choroidal thickness at 1-month
|
275.23 micrometer
Standard Deviation 20.64
|
|
Changes of Subfoveal, Temporal and Nasal Choroidal Thicknesses (Micrometer) From Baseline at 2 Months
Temporal choroidal thickness at 2-month
|
275.03 micrometer
Standard Deviation 20.56
|
|
Changes of Subfoveal, Temporal and Nasal Choroidal Thicknesses (Micrometer) From Baseline at 2 Months
Nasal choroidal thickness at baseline
|
271.16 micrometer
Standard Deviation 19.64
|
|
Changes of Subfoveal, Temporal and Nasal Choroidal Thicknesses (Micrometer) From Baseline at 2 Months
Nasal choroidal thickness at 1-week
|
271.33 micrometer
Standard Deviation 19.74
|
|
Changes of Subfoveal, Temporal and Nasal Choroidal Thicknesses (Micrometer) From Baseline at 2 Months
Nasal choroidal thickness at 1-month
|
271.75 micrometer
Standard Deviation 19.71
|
|
Changes of Subfoveal, Temporal and Nasal Choroidal Thicknesses (Micrometer) From Baseline at 2 Months
Nasal choroidal thickness at 2-month
|
271.74 micrometer
Standard Deviation 19.62
|
PRIMARY outcome
Timeframe: 2 monthsAnterior chamber depth was measured by using anterior segment module optical coherence tomography and recorded as millimeter before Nd: YAG laser posterior capsulotomy, at 1 week, at 1-month and at 2-month
Outcome measures
| Measure |
Nd: YAG Laser Posterior Capsulotomy
n=38 Participants
Posterior capsulotomy was performed by using Nd: YAG laser and macular pigment optical density, intra ocular pressure, choroidal thickness, macular thickness and anterior chamber parameters were measured before Nd: YAG laser, at 1 week, 1 month and 2 months
Nd: YAG laser posterior capsulotomy: Nd: YAG laser posterior capsulotomy
|
|---|---|
|
Changes of Anterior Chamber Depth (Millimeter) From Baseline at 2 Months
ACD at baseline
|
3.7 millimeter
Standard Deviation 0.06
|
|
Changes of Anterior Chamber Depth (Millimeter) From Baseline at 2 Months
ACD at 1-week
|
3.73 millimeter
Standard Deviation 0.06
|
|
Changes of Anterior Chamber Depth (Millimeter) From Baseline at 2 Months
ACD at 1-month
|
3.74 millimeter
Standard Deviation 0.06
|
|
Changes of Anterior Chamber Depth (Millimeter) From Baseline at 2 Months
ACD at 2-month
|
3.75 millimeter
Standard Deviation 0.07
|
PRIMARY outcome
Timeframe: 2 monthsIridocorneal angle was measured by using anterior segment module optical coherence tomography and recorded as millimeter before Nd: YAG laser posterior capsulotomy, at 1 week, at 1-month and 2-month
Outcome measures
| Measure |
Nd: YAG Laser Posterior Capsulotomy
n=38 Participants
Posterior capsulotomy was performed by using Nd: YAG laser and macular pigment optical density, intra ocular pressure, choroidal thickness, macular thickness and anterior chamber parameters were measured before Nd: YAG laser, at 1 week, 1 month and 2 months
Nd: YAG laser posterior capsulotomy: Nd: YAG laser posterior capsulotomy
|
|---|---|
|
Changes of Iridocorneal Angle From Baseline at 2 Months
ICA at 2-month
|
42.04 degree
Standard Deviation 4.18
|
|
Changes of Iridocorneal Angle From Baseline at 2 Months
ICA at baseline
|
36.59 degree
Standard Deviation 1.22
|
|
Changes of Iridocorneal Angle From Baseline at 2 Months
ICA at 1-week
|
39.92 degree
Standard Deviation 2.1
|
|
Changes of Iridocorneal Angle From Baseline at 2 Months
ICA at 1-month
|
41.62 degree
Standard Deviation 3.39
|
SECONDARY outcome
Timeframe: 2 MonthsOutcome measures
| Measure |
Nd: YAG Laser Posterior Capsulotomy
n=38 Participants
Posterior capsulotomy was performed by using Nd: YAG laser and macular pigment optical density, intra ocular pressure, choroidal thickness, macular thickness and anterior chamber parameters were measured before Nd: YAG laser, at 1 week, 1 month and 2 months
Nd: YAG laser posterior capsulotomy: Nd: YAG laser posterior capsulotomy
|
|---|---|
|
Changes of Central Macular Thicknesses (Micrometer) From Baseline at 2 Months
Central Macular Thickness Baseline
|
235.79 micrometer
Standard Deviation 13.48
|
|
Changes of Central Macular Thicknesses (Micrometer) From Baseline at 2 Months
Central Macular Thickness 1-week
|
243.08 micrometer
Standard Deviation 14.32
|
|
Changes of Central Macular Thicknesses (Micrometer) From Baseline at 2 Months
Central Macular Thickness 1-month
|
244.76 micrometer
Standard Deviation 14.82
|
|
Changes of Central Macular Thicknesses (Micrometer) From Baseline at 2 Months
Central Macular Thickness 2-month
|
245.5 micrometer
Standard Deviation 15.24
|
Adverse Events
Nd: YAG Laser Posterior Capsulotomy
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place