Evaluation of Peri-surgical Results at Short and Mean Terms of the GORE ® Excluder Iliac Branch Endoprosthesis

NCT03312127 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 3

Last updated 2020-08-26

No results posted yet for this study

Summary

The aim of this project is to demonstrate the benefit of the use of aortic iliac branch endoprosthesis in the iliac aneurysms and to avoid the classic complications.

Conditions

  • Iliac Aneurysm

Interventions

DEVICE

ILIAC ENDOPROSTHESIS GORE EXCLUDER

Set up of GORE ® Excluder Iliac Branch Endoprosthesis in endovascular barring of complex aneurysms without distal neck. In the immediate post-operating follow-up visit and at the 3 months visit and the 12 months visit after surgery, an ultra-sound scan, a tomodensitometric exam and a walking test on a treadmill with oximetric gluteal region exploration will systematically be performed.

Sponsors & Collaborators

  • University Hospital, Toulouse

    lead OTHER

Principal Investigators

  • Jean-Pierre BOSSAVY, MD · University Hospital, Toulouse

Study Design

Allocation
NA
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
50 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2017-08-01
Primary Completion
2018-07-26
Completion
2018-07-26

Countries

  • France

Study Locations

More Related Trials