Trial Outcomes & Findings for Pre-Oxygenation Techniques in Pregnancy (NCT NCT03310723)

NCT ID: NCT03310723

Last Updated: 2020-09-16

Results Overview

Concentration of oxygen at the end of a breath following 3 minutes of tidal volume breathing using either face mask or OptiFlow

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

40 participants

Primary outcome timeframe

From baseline ETO2 concentration to the end of 3 minutes of tidal volume breathing

Results posted on

2020-09-16

Participant Flow

Participant milestones

Participant milestones
Measure
Standard Face Mask Preoxygenation
Tidal volume breathing via a face mask set at 100% oxygen and a rate of 15L/min. Face Mask preoxygenation: Standard face mask preoxygenation.
Optiflow Preoxygenation
Tidal volume breathing with the OptiFlow system applied at 100% oxygen and a flow rate of 30-70L/min. OptiFlow preoxygenation: Preoxygenation using transnasal humidified rapid insufflation ventilatory exchange (THRIVE).
Overall Study
STARTED
20
20
Overall Study
COMPLETED
20
17
Overall Study
NOT COMPLETED
0
3

Reasons for withdrawal

Reasons for withdrawal
Measure
Standard Face Mask Preoxygenation
Tidal volume breathing via a face mask set at 100% oxygen and a rate of 15L/min. Face Mask preoxygenation: Standard face mask preoxygenation.
Optiflow Preoxygenation
Tidal volume breathing with the OptiFlow system applied at 100% oxygen and a flow rate of 30-70L/min. OptiFlow preoxygenation: Preoxygenation using transnasal humidified rapid insufflation ventilatory exchange (THRIVE).
Overall Study
Withdrawal by Subject
0
1
Overall Study
Protocol Violation
0
2

Baseline Characteristics

Race and Ethnicity were not collected from any participant.

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Standard Face Mask Preoxygenation
n=20 Participants
Tidal volume breathing for via a face mask set at 100% oxygen and a rate of 15L/min. Face Mask preoxygenation: Standard face mask preoxygenation.
Optiflow Preoxygenation
n=17 Participants
Tidal volume breathing with the OptiFlow system applied at 100% oxygen and a flow rate of 30-70L/min. OptiFlow preoxygenation: Preoxygenation using transnasal humidified rapid insufflation ventilatory exchange (THRIVE).
Total
n=37 Participants
Total of all reporting groups
Age, Continuous
34.8 years
STANDARD_DEVIATION 4.3 • n=20 Participants
34.6 years
STANDARD_DEVIATION 5.3 • n=17 Participants
34.7 years
STANDARD_DEVIATION 4.8 • n=37 Participants
Sex: Female, Male
Female
20 Participants
n=20 Participants
17 Participants
n=17 Participants
37 Participants
n=37 Participants
Sex: Female, Male
Male
0 Participants
n=20 Participants
0 Participants
n=17 Participants
0 Participants
n=37 Participants
Race and Ethnicity Not Collected
0 Participants
Race and Ethnicity were not collected from any participant.
Region of Enrollment
Canada
20 participants
n=20 Participants
17 participants
n=17 Participants
37 participants
n=37 Participants
Baseline end-tidal oxygen concentration (EtO2)
15.9 Percentage units
STANDARD_DEVIATION 1.2 • n=20 Participants
15.9 Percentage units
STANDARD_DEVIATION 1.5 • n=17 Participants
15.9 Percentage units
STANDARD_DEVIATION 1.35 • n=37 Participants

PRIMARY outcome

Timeframe: From baseline ETO2 concentration to the end of 3 minutes of tidal volume breathing

Concentration of oxygen at the end of a breath following 3 minutes of tidal volume breathing using either face mask or OptiFlow

Outcome measures

Outcome measures
Measure
Standard Face Mask Preoxygenation
n=20 Participants
Tidal volume breathing via a face mask set at 100% oxygen and a rate of 15L/min. Face Mask preoxygenation: Standard face mask preoxygenation.
Optiflow Preoxygenation
n=17 Participants
Tidal volume breathing with the OptiFlow system applied at 100% oxygen and a flow rate of 30-70L/min. OptiFlow preoxygenation: Preoxygenation using transnasal humidified rapid insufflation ventilatory exchange (THRIVE).
End Tidal Oxygen Concentration (ETO2) Following Tidal Volume Breathing Using Either Face Mask or OptiFlow
91.0 Percentage units of end-tidal oxygen
Interval 89.3 to 92.7
87.4 Percentage units of end-tidal oxygen
Interval 85.5 to 89.2

SECONDARY outcome

Timeframe: From baseline ETO2 concentration to the end of 8 vital capacity breaths (approximately 3 minutes)

Concentration of oxygen at the end of a breath following 8 deep breaths using either face mask or OptiFlow

Outcome measures

Outcome measures
Measure
Standard Face Mask Preoxygenation
n=20 Participants
Tidal volume breathing via a face mask set at 100% oxygen and a rate of 15L/min. Face Mask preoxygenation: Standard face mask preoxygenation.
Optiflow Preoxygenation
n=17 Participants
Tidal volume breathing with the OptiFlow system applied at 100% oxygen and a flow rate of 30-70L/min. OptiFlow preoxygenation: Preoxygenation using transnasal humidified rapid insufflation ventilatory exchange (THRIVE).
End Tidal Oxygen Concentration (ETO2) Following Vital Capacity Breaths Using Either Face Mask or OptiFlow
91.8 Percentage units
Interval 90.1 to 93.4
85.9 Percentage units
Interval 84.1 to 87.7

Adverse Events

Standard Face Mask Preoxygenation

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Optiflow Preoxygenation

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported