PRECISION Study: Evaluating the Accuracy of the LabPatch Continuous Glucose Monitor
NCT03262415 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 30
Last updated 2023-02-24
Summary
The purpose of this study is to evaluate the accuracy and efficacy of the Cambridge Medical Technologies, LLC LabPatch Continuous Glucose Monitoring (CGM) System compared to a laboratory glucose analyzer (YSI 2300 STAT Plus) and 2 commercial glucometers, OneTouch Verio and Freestyle Lite.
The LabPatch system includes:
1. The LabPatch circuit chip which lies in the center of a circular push-button. The circuit is in the form of a small chip (approximately 15.7 mm \[0.618"\] x 15.7 mm \[0.618"\]) placed in contact with the skin. The chip has a telescopic micropipette which draws interstitial fluid to be analyzed for glucose levels. The chip is also able to measure skin temperature to ensure appropriate skin contact.
2. A Lab Patch holding device (blue box).
3. A wire that connects the chip to a laptop that continuously captures glucose data.
Conditions
- Type1 Diabetes Mellitus
- Type 2 Diabetes Mellitus
Interventions
- DEVICE
-
LabPatch Continuous Glucose Monitoring (CGM)
1. The patch device that will be applied to subjects' arms in this study is about 3 inches in length and one inch in width, with adhesive tape on the sides. 2. The LabPatch circuit chip lies on the underside of the bandage. The circuit is in the form of a small chip (approximately 15.7 mm \[0.618"\] x 15.7 mm \[0.618"\]) placed in contact with the skin. The chip has a telescopic micropipette which draws interstitial fluid to be analyzed for glucose levels. The chip is also able to measure skin temperature to ensure appropriate skin contact. 3. A wire that connects the chip to a laptop that continuously captures glucose data.
Sponsors & Collaborators
-
Cambridge Medical Technologies, LLC
collaborator INDUSTRY -
Joslin Diabetes Center
lead OTHER
Principal Investigators
-
Osama Hamdy, M.D.,Ph.D · Joslin Diabetes Center
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-02-17
- Primary Completion
- 2019-05-22
- Completion
- 2019-05-22
Countries
- United States
Study Locations
More Related Trials
-
Factors in Accuracy Studies Influencing Measured CGM Performance.
NCT02843503 ·Status: COMPLETED ·Phase: NA
-
Warming up to Sensors: Does Site Warming Improve Continuous Glucose Monitor Performance?
NCT01954459 ·Status: TERMINATED ·Phase: EARLY_PHASE1
-
Continuous Glucose Monitoring in Patients With Type 2 Diabetes
NCT00529815 ·Status: UNKNOWN ·Phase: PHASE4
-
Continuous Glucose Monitoring in Diabetes and Prediabetes
NCT03805412 ·Status: COMPLETED ·Phase: NA
-
Community Glucose Monitoring Project
NCT05351190 ·Status: UNKNOWN ·Phase: NA
-
Is Real-time CGM Superior to Flash Glucose Monitoring in Real Life Study (CORRIDA LIFE)
NCT04759495 ·Status: UNKNOWN ·Phase: NA
-
Effectiveness and Safety Study of the Next-Generation DexCom™ SEVEN® Continuous Glucose Monitoring System
NCT00722241 ·Status: COMPLETED
-
Dexcom G6 Intervention Study
NCT03877068 ·Status: COMPLETED ·Phase: NA
-
Safety and Effectiveness of the MiniMed™ 780G System With DS5 CGM
NCT05714059 ·Status: COMPLETED ·Phase: NA
-
Continuous Glucose Monitors to Regulate Glucose Levels in Type 2 Diabetics
NCT03252964 ·Status: COMPLETED ·Phase: NA
-
Studying the Effectiveness of Non-Invasive Glucose Sensors in Patients With Diabetes: The SENSOR Study
NCT02800044 ·Status: TERMINATED ·Phase: NA
-
Continuous Glucose Monitors to Regulate Glucose Levels in Type 2 Diabetics - (Protocol 3)
NCT03290768 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Dexcom G5 Mobile Continuous Glucose Monitoring (CGM) System and the FreeStyle Libre Flash Glucose Monitoring System
NCT03602963 ·Status: COMPLETED
-
Continuous Glucose Monitoring (CGM) in Subjects With Type 2 Diabetes
NCT01341067 ·Status: COMPLETED
-
Satisfaction of Hospitalized Diabetic Patients Using a Continuous Glucose Monitoring System
NCT03411460 ·Status: TERMINATED ·Phase: NA
-
Time in Glucose Hospital Target
NCT05135676 ·Status: COMPLETED ·Phase: NA
-
Continuous Glucose Monitoring in the Intensive Care Unit
NCT06190808 ·Status: COMPLETED ·Phase: NA
-
Is Real-time CGM Superior to Flash Glucose Monitoring
NCT04358263 ·Status: UNKNOWN ·Phase: NA
-
G5® Mobile Continuous Glucose Monitoring System Automated vs. Manual Sensor Applicator
NCT02696252 ·Status: COMPLETED
-
Assessment of an Integrated Continuous Glucose Monitor and Insulin Injection Port in Type 2 Diabetes
NCT05185518 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Accuracy of Two CGM Systems Tested Simultaneously in Ambulatory Patients With Type 1 Diabetes
NCT02159638 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Safety and Effectiveness of the Dexcom Continuous Glucose Monitoring (CGM) System
NCT04794478 ·Status: COMPLETED ·Phase: NA
-
A Comparison Study of Prototype Continuous Glucose Sensors in the Intradermal and Subcutaneous Spaces
NCT01093833 ·Status: COMPLETED ·Phase: PHASE1
-
Standardized Procedure for the Assessment of New-to-market Continuous Glucose Monitoring Systems
NCT01751932 ·Status: COMPLETED ·Phase: NA
-
Effectiveness and Safety of the Dexcom™ G6 Continuous Glucose Monitoring System
NCT02880267 ·Status: COMPLETED ·Phase: NA