Delphinus SoftVue Prospective Case Collection - ARM 1
NCT03257839 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 7409
Last updated 2021-09-05
Summary
The SoftVue™ is a whole breast ultrasound system with an automated scanning curvilinear ring-array transducer that employs UST. It is currently cleared under FDA 510(k) K123209 and K142517 for use as both a B-mode ultrasonic breast imaging system and color imaging of transmission data (sound speed and attenuation). SoftVue™ is not intended to be used as a replacement for screening mammography.
SoftVue uses non-ionizing ultrasound energy to generate tomographic image volumes of the whole breast. While the patient lays prone on a padded table with one breast comfortably submerged in a bath of warm water, a ring-shaped transducer, 22 cm in diameter, encircles the breast and pulses low-frequency sound waves through the water and into the breast tissue. More than 2000 elements in the curvilinear transducer's 360 degree array emit and receive ultrasound signals to analyze echoes from the breast anatomy in all directions, from the chest wall to the nipple. Not only does SoftVue capture data from the reflection of the sound waves off of tissue boundaries and structures within the breast, but because the transducer surrounds the whole breast, SoftVue also captures signals that are transmitted through the breast. This additional transmission data enhances the visualization of the anatomic structure of the breast tissue and is not currently available in any other commercially marketed breast ultrasound device.
This prospective, multicenter, multi-arm, clinical case collection program is IRB-approved and will be conducted in compliance with Good Clinical Practice, the Declaration of Helsinki and all applicable regulatory requirements. Arm 1 aims to collectively enroll up to 17,500 women at a total of up to 8 clinical sites. The design of this protocol is strictly limited to case collection; all investigational and statistical plans for future analyses will be prepared and registered separately, if they are applicable to the requirements of FDAAA 801.
Arm 1 is limited to the cohort of asymptomatic women, with heterogeneously or extremely dense breast parenchyma (BI-RADS breast composition category c or d). Matched triads of 2D digital mammography (FFDM), 3D digital mammography (DBT), and SoftVue automated whole breast ultrasound (SV)exams, from the same patient, with demographic information and clinical outcome data, will be collected during the same screening imaging episode. Ultrasound characteristics for all types of lesions, whether they are benign or malignant, will be collected, as well as objective and subjective breast density composition data.
The exams and clinical data accumulated in this prospective case collection (PCC) protocol will populate a database from which future investigations may be designed for peer reviewed publication, development of user training curriculums, building teaching case, and creating new marketing materials for SoftVue.A subset of exams will be sampled from Arm 1 for use in ROC Reader Study (protocol DMT-2015.002), which will be separately registered and is designed to evaluate the safety and efficacy of a new screening indication for use of SoftVue™ as an adjunct to screening mammography. The results of this ROC Reader Study will be submitted to the FDA for their consideration of a PMA application for SoftVue.
Conditions
- Breast Neoplasms
Interventions
- DEVICE
-
Routine Full-Field Digital Mammography
Routine screening mammography exam, CC + MLO views.
- DEVICE
-
Routine Digital Breast Tomosynthesis
Routine screening tomosynthesis exam, CC + MLO views.
- DEVICE
-
Automated Whole Breast Ultrasound
Bilateral breast ultrasound performed as an adjunct to mammography.
Sponsors & Collaborators
-
Delphinus Medical Technologies, Inc.
lead INDUSTRY
Principal Investigators
-
Mary W Yamashita, MD · Keck School of Medicine, University of Southern California
Eligibility
- Min Age
- 18 Years
- Sex
- FEMALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2017-07-31
- Primary Completion
- 2021-01-31
- Completion
- 2021-07-31
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Contrast-Enhanced Subharmonic Ultrasound Imaging in Improving Characterization of Adnexal Masses in Patients Undergoing Surgery
NCT03297112 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Diagnosing Obstructive Lung Disease With Point of Care Ultrasound
NCT06251271 ·Status: COMPLETED
-
Diagnostic Accuracy of Handheld vs Traditional Ultrasound
NCT05196776 ·Status: COMPLETED ·Phase: NA
-
A Study Assessing the Safety and Utility of PINPOINT® Near Infrared Fluorescence Imaging in the Identification of Lymph Nodes in Patients With Uterine and Cervical Malignancies Who Are Undergoing Lymph Node Mapping
NCT02209532 ·Status: COMPLETED ·Phase: NA
-
Avecure Flexible Microwave Ablation Probe For Lung Nodules
NCT05281237 ·Status: RECRUITING ·Phase: NA
-
Comparison of a Novel Ultrasound System Versus Standard Imaging Modalities
NCT05748106 ·Status: UNKNOWN
-
Safety and Effectiveness Study for a Needle Guidance System in Lung Biopsies
NCT01183182 ·Status: COMPLETED ·Phase: PHASE4
-
Exploring New and Next Generation Ultrasound Technologies for Medical Education, Patient Care, and New Indications
NCT03486444 ·Status: WITHDRAWN ·Phase: NA
-
Respiration Gated Laser Guided CT Lung Nodule Biopsy
NCT01236937 ·Status: UNKNOWN ·Phase: NA
-
Real-Time Contrast-Enhanced Ultrasonography and Shear Wave Elastography in Predicting Treatment Response in Patients With Soft Tissue Sarcoma
NCT02384473 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Feasibility Study of the Microwave Ablation System for Lung Tissue Ablation
NCT06158971 ·Status: RECRUITING ·Phase: NA
-
SAVI SCOUT Clinical Evaluation Study
NCT02370082 ·Status: UNKNOWN ·Phase: NA
-
Thin and Ultrathin Bronchoscopy With Transbronchial Needle Aspiration and Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions
NCT04331587 ·Status: COMPLETED
-
Point of Care Ultrasound (POCUS) for Diagnosis and Treatment of Fractures in the Costal Cartilage
NCT07338617 ·Status: NOT_YET_RECRUITING
-
Study Using Combined Virtual 4-D Electromagnetic (EM) Tip-Tracked Devices & EBUS in Diagnosis of Lung Nodules
NCT01947530 ·Status: COMPLETED ·Phase: NA
-
Contrast Enhanced Ultrasound Medical Imaging for Identifying Breast Masses
NCT06171607 ·Status: RECRUITING ·Phase: PHASE1
-
Feasibility of Multi-Energy Digital Radiography Detector for Lung Lesions Detection
NCT03528733 ·Status: UNKNOWN ·Phase: NA
-
Near Infrared Fluorescence Imaging With Indocyanine Green
NCT02851368 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Safety & Accuracy Study of the ActiSight Needle Guidance System in Patients Undergoing CT-Guided Percutaneous Chest Aspiration and Biopsy
NCT00819533 ·Status: COMPLETED ·Phase: NA
-
Image - Navigated Resection of Lung Nodules
NCT04702165 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
CT Biomarkers Identification by Artificial Intelligence for COVID-19 Prognosis
NCT04418245 ·Status: WITHDRAWN
-
DOLPHIN-VIVO: Diagnosis Of LymPHoma IN Vivo (Ex Vivo Phase)
NCT04162431 ·Status: COMPLETED
-
The Use of Artificial Intelligence to Predict Cancerous Lymph Nodes for Lung Cancer Staging During Ultrasound Imaging
NCT03849040 ·Status: COMPLETED
-
Mayo Designed Soft Tissue Ultrasound-Detectable Marker
NCT04674852 ·Status: COMPLETED ·Phase: NA
-
Contrast-Enhanced Ultrasound Scan for the Estimation of Tissue Pressure in Patients With Breast Cancer
NCT04721886 ·Status: COMPLETED ·Phase: EARLY_PHASE1