Direct Measurement of Ideal Depth of Central Line
NCT03116724 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 89
Last updated 2020-06-16
Summary
Total of 89 patients undergoing elective cardiac surgery will be enrolled.
Right CVC insertion begins at their intersection of the cricoid cartilage level and the triangular point where the sternal head of the SCM muscle meets the clavicular head. After insertion the central venous catheter through the right internal jugular vein and positioning it, the location of the tip of the central venous catheter will be confirmed by TEE.
Conditions
- Patient Safety During Central Venous Catheterization
Interventions
- PROCEDURE
-
central venous catheterization through Rt. IJV
* insertion at the intersection of the cricoid cartilage level and the triangular point where the sternal head of the SCM muscle meets the clavicular head * placement of the tip of the catheter 2 cm away from the junction between right atrium and superior vena cava using TEE * measurement of the depth of the catheter at insertion point
Sponsors & Collaborators
-
Keimyung University Dongsan Medical Center
lead OTHER
Principal Investigators
-
Jiwon Lee, Dr. · Dongsan Medical Center
Study Design
- Allocation
- NA
- Purpose
- SUPPORTIVE_CARE
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-04-05
- Primary Completion
- 2017-08-25
- Completion
- 2017-08-28
Countries
- South Korea
Study Locations
More Related Trials
-
Correct Tip Position of Central Venous Catheters
NCT05176886 ·Status: COMPLETED
-
Comparison of the Needle Tip Location by the Position of the Operator During Ultrasound Guided LIJV Catheterization.
NCT03936543 ·Status: UNKNOWN ·Phase: NA
-
Siting Central Venous Catheters Precisely While Performing the Access Procedure
NCT05751395 ·Status: UNKNOWN
-
A Difference in Subclavian Vein Catheterization Between Supine and Lateral Tilt Position - Stage I
NCT03296735 ·Status: UNKNOWN ·Phase: NA
-
Swan-Ganz CCOmbo V for Obtaining an Optimal Depth of Right Internal Jugular Venous Catheter
NCT03544151 ·Status: COMPLETED
-
Influence of the Shoulder Position on the Catheter Tip Location During Infraclavicular Subclavian Approach
NCT01024881 ·Status: COMPLETED ·Phase: NA
-
Effect of the Bevel Direction of Puncture Needle on Success Rate and Complications During Central Venous Catheterization
NCT01003366 ·Status: COMPLETED ·Phase: NA
-
Central Venous Catheter Insertion Techniques
NCT05387486 ·Status: COMPLETED ·Phase: NA
-
Central Venous Pressure and Right Atrial Pressure Measurements in Supine, Semi-recumbent and Trendelenburg Position
NCT06705374 ·Status: COMPLETED
-
Does the Central Venous Puncture Needle Need to be 7 cm?
NCT05877794 ·Status: UNKNOWN ·Phase: NA
-
Central Landmark vs USG for IJV Catheterization
NCT01931969 ·Status: UNKNOWN
-
Ultrasound Guided Central Venous Vascular Access - Novel Needle Navigation Technology Compared With Conventional Method
NCT03214575 ·Status: COMPLETED ·Phase: NA
-
Central Venous Catheter Placement With Thoracic Ultrasound and Intracavity ECG Positioning
NCT07291869 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Contralateral Head Rotation on Internal Jugular Vein to Carotid Artery Distance and Overlap Ratio
NCT03741946 ·Status: COMPLETED ·Phase: NA
-
Accuracy of CVC Depth Prediction in Internal Jugular Veins: The Difference Between The Andropoulos and ECG Methods
NCT04215250 ·Status: COMPLETED ·Phase: NA
-
Supraclavicular Fossa US View for Catheter Positioning in Right Subclavian Central Venous Catheterization
NCT03812757 ·Status: COMPLETED
-
Comparison of Central Venous Pressures (CVPs) Measured From Peripherally Inserted Central Catheters (PICC) and CICC in Liver Transplantation Recipients
NCT00988871 ·Status: COMPLETED
-
Verification of the Correct Insertion of a Central Venous Catheter
NCT06109584 ·Status: RECRUITING ·Phase: NA
-
A Randomized Parallel Study for Simulated Internal Jugular Vein Cannulation Using Simple Needle Guide Device
NCT03252197 ·Status: COMPLETED ·Phase: NA
-
3D Guided Internal Jugular Vein Catheterization
NCT04683302 ·Status: COMPLETED ·Phase: NA
-
Dynamic SAX vs Conventional LAX in Internal Jugular Vein Catheterization
NCT03841968 ·Status: COMPLETED ·Phase: NA
-
Influence of Arm Retraction on the Supraclavicular Approach for Subclavian Vein Catheterization
NCT02478749 ·Status: COMPLETED ·Phase: NA
-
Ultrasound Guided Central Vein Catheterization and Complications
NCT01510743 ·Status: COMPLETED ·Phase: NA
-
A Study of the IJV or the SCV Approach for Ultrasound-guided Implantation of TIVAD
NCT03945045 ·Status: UNKNOWN ·Phase: NA
-
Safety Study of Subclavian and Internal Jugular Venous Catheterization
NCT01196962 ·Status: UNKNOWN ·Phase: NA