Optimal Insertion Depth of Left Internal Jugular Vein Catheter in Infants

NCT03025178 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 46

Last updated 2019-09-16

No results posted yet for this study

Summary

We previously performed a study to create formula for the optimal insertion depth of left internal jugular vein catheter in infant, which was registered at cris.nih.go.kr. We found that two calculation methods using height and the distance between landmarks (0.11 × height (cm) + 0.19 and 1.02 × I-A-B (cm) + 1.55, where I was insertion point of needle, A was the most prominent point of the sternal head of the left clavicle, and B was the midpoint of the perpendicular line drawn between the sternal head of the right clavicle and an imaginary line between the nipples) were clinically feasible to determine the insertion depth of left internal jugular vein catheter. In this study, we will compare the actual insertion depth with the insertion depth determined from above two calculation methods in other 46 infants.

Conditions

  • Central Venous Catheter
  • Infant

Interventions

PROCEDURE

4Fr central venous catheter insertion

The central venous catheter is placed at left internal jugular vein in infant, and its tip is confirmed by transthoracic echocardiography.

Sponsors & Collaborators

  • Seoul National University Hospital

    lead OTHER

Principal Investigators

  • Hee-Soo Kim, MD, PhD · Seoul National University Hospital

Study Design

Allocation
NA
Purpose
OTHER
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Max Age
1 Year
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2017-03-08
Primary Completion
2018-03-09
Completion
2018-04-01

Countries

  • South Korea

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.