Feasibility and Predictive Accuracy of an In-Home Computer Controlled Mandibular Positioner in Identifying Favorable Candidates for Oral Appliance Therapy
NCT03011762 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 202
Last updated 2018-06-27
Summary
Sleep apnea is a condition in which the throat air passage closes during sleep and repeatedly interrupts breathing. The standard treatment of sleep apnea is air pressure applied to the nose, so-called nasal CPAP, but it is not suitable for all patients. Another treatment is to use a dental appliance while asleep. In this treatment, an appliance covers the upper and lower teeth and acts to pull the jaw forward, which opens the throat passage. This allows the patient to breathe normally.
Dental appliance treatment does not work effectively in all patients. In order to identify those in whom dental appliance therapy will be effective, the study sponsor has invented the remotely controlled mandibular positioner, MATRx. The MATRx is an FDA cleared motorized dental appliance which is used overnight in hospital sleep studies and works by pulling the jaw outward under the control of a technician.
In order to eliminate the need for an overnight in hospital sleep study, the sponsor has invented a new device that allows for the identification of individuals who are suitable candidates for dental appliance therapy from the comfort of the home. Like with MATRx, participants will sleep with a motorized mandibular positioner in place. But, it is controlled by a computer, rather than a sleep technician, making it a computer controlled mandibular positioner (CCMP). The feasibility and predictive accuracy of multi night testing using the CCMP will be evaluated through participation in this study.
The sponsor has carried out two previous research trials leading to the development of the CCMP. The first established the predictive accuracy of the remotely controlled mandibular positioner at identifying candidates suitable for oral appliance therapy and their effective therapeutic setting. The second established the accuracy of the algorithms used by the CCMP to similarly identify successful candidates in a clinical setting. No significant problems were identified in conjunction with our previous research protocol, and no significant risks were identified. This third protocol is to establish the feasibility and accuracy of the CCMP when used in the home setting.
The trial will utilize data collected over a series of nights to formulate a prediction of therapeutic outcome with an oral appliance. The prediction will be tested by comparing the degree of airway obstruction without treatment (from data collected prior to the study) to the degree of airway obstruction with oral appliance therapy. A custom fit oral appliance will be provided to participants as part of the trial.
The purpose of the study is to test the predictive accuracy of the CCMP in identifying favorable candidates for oral appliance therapy and in determining an efficacious protrusive position. Another purpose is to evaluate the convenience and possibility of carrying out a multi-night CCMP study in the home.
There are no known risks or side effects to the CCMP studies, to the home studies, or to the oral appliance therapy. It is possible that participants will have some discomfort during the nights of the CCMP studies but this will be transient and not cause any long term damage. Participants may experience soreness of the teeth or jaw joint during adjustment of the oral appliance by the dentist. There is no risk of jaw dislocation or problems with the temporomandibular joint (TMJ).
Participants will have the benefit of receiving a dental appliance for treating their sleep apnea at no charge. This will be supplied to participants by a dentist who is an expert in this field. Participation in the study will also allow the further development and ultimately commercialization of the CCMP device which may help individuals who have sleep apnea.
Dental appliance therapy is just one of two therapies for sleep apnea. If participants choose not to have the dental appliance therapy, they may wish to try nasal continuous positive airway pressure. Participants may withdraw at any time during the study without compromising their health care in any way. To withdraw, participants should simply notify one of the physicians or the research assistant. If the sponsor obtains new information that might affect an individual's willingness to participate in the study, they will be informed immediately.
Conditions
- Sleep Apnea, Obstructive
Interventions
- DEVICE
-
Computer controlled mandibular positioner
Participants in this arm will complete the computer controlled mandibular positioner test. The study participant, study dentist, and PI are all blinded to the outcome of the CCMP test. Those participants predicted to experience therapeutic success with OAT will have their oral appliance set at the predicted protrusive level; those participants predicted to experience therapeutic failure will have their oral appliance set at a default position. Outcome home sleep tests with the oral appliance in place will be used to determine the accuracy of the prediction.
Sponsors & Collaborators
-
Zephyr Sleep Technologies
lead INDUSTRY
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 21 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-11-30
- Primary Completion
- 2016-10-31
- Completion
- 2016-10-31
More Related Trials
-
Combinations of Oral Appliance and CPAP for Patients With Severe Obstructive Sleep Apnea Untolerate High-pressure CPAP
NCT02217397 ·Status: UNKNOWN ·Phase: NA
-
Continuous Positive Airway Pressure and Oral Appliances Treatments in Mild Obstructive Sleep Apnea
NCT01461486 ·Status: COMPLETED ·Phase: NA
-
Effects From a Mandibular Repositioning Appliance in Patients With Obstructive Sleep Apnea and Snoring
NCT00477009 ·Status: COMPLETED ·Phase: NA
-
Predictive Accuracy of MATRx Plus in Identifying Favorable Candidates for Oral Appliance Therapy
NCT03217383 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Simple Continuous Positive Airway Pressure on Patients With Obstructive Sleep Apnea
NCT03782844 ·Status: COMPLETED ·Phase: NA
-
Treatment of Sleep Apnea Syndrome With nCPAP Versus Oral Appliance
NCT00152672 ·Status: UNKNOWN ·Phase: NA
-
Evaluating Instrumentation for Dental Devices Used in Treating Sleep Apnea
NCT02056327 ·Status: COMPLETED
-
Increasing the Use of an Anti-snoring Mouth Guard (Mandibular Advancement Appliance) to Prevent Upper Airway Collapse During Sleep in Patients With Obstructive Sleep Apnoea.
NCT04092660 ·Status: RECRUITING ·Phase: NA
-
Positive Pressure Treatment of Obstructive Sleep Apnea
NCT00636181 ·Status: COMPLETED ·Phase: NA
-
Impact of the Mandibular Advancement Device on Sleep Apnea During CPAP Withdrawal
NCT05939934 ·Status: RECRUITING ·Phase: NA
-
Airway Muscle Activation on Sleep-disordered Breathing Events
NCT06002061 ·Status: RECRUITING ·Phase: NA
-
Positional Therapy to Treat Obstructive Sleep Apnea in Stroke Patients
NCT03558659 ·Status: TERMINATED ·Phase: NA
-
Multinight CPAP for Sleep Apnea Patients
NCT02635100 ·Status: TERMINATED ·Phase: NA
-
Clinical Study of Customized Adjustable Oral in Treatment of Patients With Obstructive Sleep Apnea Syndrome
NCT03729895 ·Status: UNKNOWN ·Phase: NA
-
Adherence and Preference of Continuous Positive Airway Pressure Versus Mandibular Advancement Splints in Obstructive Sleep Apnea Patients: A Randomized Trial
NCT02242617 ·Status: COMPLETED ·Phase: NA
-
Dental Device for Treatment of Sleep Apnea
NCT01005940 ·Status: COMPLETED ·Phase: NA
-
Assessment of the Effect of PAP on Energy and Vitality in Mild OSA Patients: The Merge Study
NCT02699463 ·Status: COMPLETED ·Phase: NA
-
Therapy of Oral Appliance for Adults Jordanians With Obstructive Sleep Apnea
NCT05087316 ·Status: COMPLETED ·Phase: NA
-
Effect of Oral Appliance Therapy on Glucose Levels in Patients With T2DM and OSA: A Pilot Trial
NCT03167684 ·Status: UNKNOWN ·Phase: NA
-
Titration of Continuous Positive Airway Pressure Could Predict Success of Oral Appliance to Treat Sleep Apnea
NCT01336556 ·Status: UNKNOWN ·Phase: NA
-
Effects of Two Different Amounts of Mandibular Protrusion in OSA Patients Using Mandibular Advancement Appliance
NCT04079153 ·Status: UNKNOWN ·Phase: NA
-
Use of Passive Myofunctional Appliances for Snoring and Mild Obstructive Sleep Apnea
NCT05497180 ·Status: RECRUITING ·Phase: PHASE1
-
Evaluation of the Comfort of a Continuous Positive Airway Pressure Nasal Mask in the Treatment of OSA Syndrome
NCT04925739 ·Status: COMPLETED
-
The POSA Trial - Positional Therapy for Positional OSA
NCT04153240 ·Status: COMPLETED ·Phase: NA
-
Acceptance of Mandibular Advancement Devices
NCT06970171 ·Status: ENROLLING_BY_INVITATION ·Phase: NA