Optimal Positioning of Nasopharyngeal Temperature Probes
NCT02993003 · Status: WITHDRAWN · Phase: NA · Type: INTERVENTIONAL
Last updated 2018-01-25
Summary
Core temperature is of greatest interest in terms of temperature monitoring as it is thought to represent the temperature of the vessel-rich groups that are instrumental in thermoregulatory control. The nasopharynx is among the recommended temperature monitoring sites for core body temperature. It is the part of the pharynx that lies above the soft palate. Anteriorly it opens to the nasal cavities through the choanae; inferiorly it communicates with the oropharynx through the pharyngeal isthmus. Nasopharyngeal temperatures are accurate in adults when probes are inserted between 10 and 20 cm.
The optimal depth for insertion of nasopharyngeal probes remains poorly defined in infants and children. While some data suggest that anthropometric measurements are well correlated with endoscopic measurements in infants based on weight, the accuracy of temperature measurements at these and other distances has yet to be quantified. The investigators thus propose to determine the insertion depth (or range of depths) for nasopharyngeal temperature proves that best approximate core temperature as measured in the distal esophagus in infants and children of various sizes. The comparison site will be the distal esophagus since there is broad consensus that the distal third of the esophagus it at core-body temperature.
For the two groups of infants aged up to twelve months, the nasopharyngeal probe will be marked with indelible ink from 2-10 cm in 1-cm increments and inserted 10 cm. For the two groups of children between 1 and 5 years, the nasopharyngeal probe will be marked with indelible ink from 2-15 cm in 1.5-cm increments and inserted 10 cm. For older children, a nasopharyngeal probe will be marked with indelible ink from 2 to 20 cm at 2 cm increments from its tip, and inserted 20 cm.
Both nasopharyngeal and esophageal temperatures will initially be recorded 30 minutes after induction of anesthesia. Nasopharyngeal probes will then be withdrawn at the designated increment for each age group and will be equilibrated for 5 minutes before the temperature is recorded. Thereafter, the nasopharyngeal withdrawal sequence will be repeated. The number of measurement will depend on the initial depth of insertion, with measurements continuing until only 2 centimeters remain in the nostril.
Conditions
- Accuracy of Nasopharyngeal Probes
Interventions
- DEVICE
-
Nasopharyngeal probe
nasopharyngeal probe insertion
Sponsors & Collaborators
-
The Cleveland Clinic
lead OTHER
Principal Investigators
-
Daniel Sessler, M.D. · The Cleveland Clinic
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- OTHER
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 7 Months
- Max Age
- 12 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2015-11-30
- Primary Completion
- 2017-10-31
- Completion
- 2017-10-31
Countries
- United States
Study Locations
More Related Trials
-
Sex and Age Ultrasound Response to Differential Jugular Vein Pressure
NCT03017937 ·Status: COMPLETED ·Phase: NA
-
EEG Characteristics in Youth POTS and/or Syncope
NCT02167412 ·Status: COMPLETED
-
Central Blood Pressure and Pulse Wave Velocity in Kidney Transplant Recipients
NCT04212143 ·Status: ACTIVE_NOT_RECRUITING
-
Quantification of Brain and Kidney Perfusion Before, During, and After Hypothermia Treatment in Neonates With Perinatal Asphyxia Using Contrast-enhanced Ultrasound
NCT06611254 ·Status: RECRUITING
-
Ultrasound Measurement of RIJV in Patients Between 0-2 Years
NCT03604094 ·Status: COMPLETED
-
Ambulatory Blood Pressure Measurement in Children With Congenital Urine Flow Obstruction
NCT00764543 ·Status: NO_LONGER_AVAILABLE
-
Optical Measurement of Cerebral Hemodynamics in Children With Acute Arterial Ischemic Stroke
NCT01786785 ·Status: COMPLETED
-
Assessment of CSF Shunt Flow With Thermal Measurements A
NCT05015751 ·Status: COMPLETED
-
Radiation Dose of Pediatric Patients During Ureteroscopy
NCT02895711 ·Status: COMPLETED
-
The Relationship Between Trans-diaphragmatic Pressure and Diaphragmatic Contraction
NCT03802383 ·Status: RECRUITING
-
ShuntCheck Performance Characteristics in Asymptomatic Pseudotumor Cerebri Patients
NCT04309383 ·Status: COMPLETED
-
Optimal Timing for Repair of Left to Right Shunt Lesions
NCT00229827 ·Status: TERMINATED
-
Descriptive Analysis of Near Infrared Spectroscopy in Critically Ill and Injured Pediatric and Neonatal Patients
NCT02950181 ·Status: TERMINATED ·Phase: NA
-
Study on Prediction of Fluid Responsiveness Using an Abdominal Compression-induced Change of Blood Pressure in Children
NCT02471534 ·Status: COMPLETED ·Phase: NA
-
Capillary Refill Time Measurement Utilizing Mobile Application in Children
NCT05472116 ·Status: COMPLETED
-
Promoting Children's Participation in Conventional X-ray Examinations
NCT06322264 ·Status: RECRUITING
-
Non-invasive Intracranial Pressure (ICP) Monitoring in Pediatric Patients
NCT02695264 ·Status: WITHDRAWN ·Phase: NA
-
Non Invasive Measurement With Trans Cranial Doppler Versus Invasive Measurement in Pediatric Age
NCT05340062 ·Status: RECRUITING
-
Pediatric Acute Gastrointestinal Bleeding Registry
NCT03090945 ·Status: UNKNOWN
-
EEG Alterations in Preterm Infants With Thyroid Dysfunction
NCT03493113 ·Status: COMPLETED
-
Measuring Thickness of the Normal Diaphragm in Children Via Ultrasound.
NCT04589910 ·Status: COMPLETED ·Phase: NA
-
Thermal Camera Detection of Ventriculoperitoneal Shunt Flow
NCT03451669 ·Status: COMPLETED
-
Safety and Efficacy of Devices Used in Fetoscopic Neural Tube Defect Repair Cases
NCT05672849 ·Status: RECRUITING ·Phase: NA
-
Bench Study of Transcutaneous Hydrocephalic Shunt Flow Sensor Alignment Accuracy and Repeatability
NCT00651950 ·Status: WITHDRAWN
-
Estimation of Central Venous Pressure by Echocardiography in Intubated Children in Pediatric Intensive Care
NCT05195424 ·Status: UNKNOWN