Novel Offloading for Diabetic Foot Ulcers With PulseFlow: A Prospective Study

NCT02783066 · Status: COMPLETED · Phase: PHASE2 · Type: INTERVENTIONAL · Enrollment: 16

Last updated 2020-08-12

Study results available
· View outcomes & findings →

Summary

Diabetic foot ulceration (DFU) is a common and largely preventable complication of diabetes. While most of these ulcers can be treated successfully, some will persist and become infected. Ultimately, nearly one fifth of patients with infected lower-extremity diabetic ulcers will require amputation of the affected limb, resulting in staggering costs for both the patient and the healthcare system. Prevention by identifying people at higher risk is key for better clinical management of such patients. It is not uncommon for patients suffering from diabetes to have concomitant lower extremity edema or venous insufficiency and they subsequently may benefit from graduated compression. However, because of the common association of peripheral arterial disease (PAD) in patients with diabetes, most clinicians are reluctant to apply compressive dressings in fear of exacerbating the symptoms of PAD and possibility of gangrene.

A novel low voltage, battery powered medical device, PulseFlow DF® (The Diabetic Boot Company, Ltd. UK) has endeavored to assist in the treatment of Diabetic Foot Ulcers. The device provides hybrid functionality i.e. mobile air bladder pump at plantar arch and offloading boot. The air bladder inflates to 160 mmHg for approx. 1 second then deflates back to atmospheric pressure, allowing the plantar vessels sufficient time to refill. The offloading boot design holds the foot and lower leg in a position that reduces shear and friction forces and provides a reduction in plantar pressure.

The PulseFlow DF is designed to record how many hours of blood pumping it has delivered. This data will be downloaded at each clinic visit. The boot cannot pump blood around the participant's foot unless fitted correctly and the battery is charged up overnight.

The purpose of this study is to conduct an interventional study study with N=15 diabetic subjects with active foot ulcers to assess whether PulseFlow foot compression device can help improve lower extremity perfusion, whilst improving balance and spatio-temporal parameters of gait.

The key goals of the proposed project are to test whether a specially designed compression device can improve lower extremity perfusion, whilst also simultaneously improving the balance and walking performance. Investigators envision the use of this specially designed offloading device with compression capability will help reduce the incidence of diabetic foot ulcers in high-risk diabetic patients. In addition, investigators assumed the proposed device might enhance daily physical activity as well as walking performance. Investigators will conduct a prospective clinical study to validate these hypotheses. Potential changes in walking and spontaneous daily physical activities will be assessed using validated technologies that include walking analyzer system, balance assessment using body worn sensors, and computerized pressure insoles.

Conditions

  • Diabetic Foot Ulcer
  • Offloading

Interventions

DEVICE

Offloading boot: PulseFlow

A new offloading boot, which may enhance balance, gait, and lower extremity blood flow

Sponsors & Collaborators

  • The Diabetic Boot Company

    collaborator INDUSTRY
  • Baylor College of Medicine

    lead OTHER

Study Design

Allocation
NA
Purpose
SUPPORTIVE_CARE
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Max Age
80 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2016-01-31
Primary Completion
2019-06-30
Completion
2019-10-30

Countries

  • United States

Study Locations