Comparison of the Vasomotor Function and Myocardial Flow in Patients Treated With Bioresorbable and Metallic Stents at 1 Year

NCT02738658 · Status: COMPLETED · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 70

Last updated 2018-07-03

No results posted yet for this study

Summary

Background: A total of 25-50% of patients with stable coronary atherosclerosis treated with metallic stent implantation remain with effort angina despite optimal medical treatment and absence of stent restenosis at 1 year. The most plausible cause of persistent effort angina after stent implantation is microcirculatory dysfunction. Coronary circulation matches the myocardial blood supply and oxygen consumption. Metallic stent implantation has been related with endothelial dysfunction and impaired coronary blood flow reserve (relation between coronary blood flow at rest and maximal hyperemia) of the treated vessel at 1 year.

Bioresorbable Vascular Scaffold (BVS) has been shown to improve the endothelial function and to improve the angina symptoms at 1 year. However, the coronary blood flow of BVS has never been tested.

Main objective: To determine differences in the blood average peak velocity at maximal hyperemia with adenosine infusion between patients treated with bioresorbable and metallic coronary stents at 1 year after stent implantation.

Methodology: A total of 70 patients are 1:1 randomized to everolimus-eluting metallic stent (EES) versus everolimus-eluting BVS implantation in patients with stable coronary disease. At 1 year, patients undergo to invasive coronary angiography prior cessation of vasomotor drugs. A pressure/Doppler wire is advanced distally to the "treated segment" and the endothelial (acetylcholine) and non-endothelial (adenosine and nitroglycerine) vasomotor function is assessed with quantitative coronary angiography and pressure and Doppler measurements. Angina test questionnaires are obtained at different time-points of the study.

Expected results: A difference between patients treated with BVS and EES of 12.0 cm/sc in the maximal average peak velocity (APV) under maximal hyperemia (with adenosine administration) is expected, as assessed by Doppler measurements, at 1 year after stent implantation. The study is powered to assess superiority in terms of maximal APV favoring patients treated with BVS.

Conditions

  • Stable Angina

Interventions

DEVICE

Bioresorbable vascular scaffold

DEVICE

Everolimus-eluting stent

Sponsors & Collaborators

  • Fundació La Marató de TV3

    collaborator OTHER
  • Institut d'Investigació Biomèdica de Bellvitge

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
OTHER
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2015-03-01
Primary Completion
2018-07-02
Completion
2018-07-02

Countries

  • Spain

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT02738658 on ClinicalTrials.gov