Korean Multicenter Registry of EPIC Stent for Iliac Artery Disease: (K-EPIC Registry)
NCT02698358 · Status: UNKNOWN · Type: OBSERVATIONAL · Enrollment: 68
Last updated 2019-01-29
Summary
* Prospective, single-arm, multi-center registry study
* A total of 150 subjects with iliac artery disease who meet all inclusion and exclusion criteria will be included.
* Patients will be followed clinically for 12 months after the procedure.
* Duplex ultrasound, CT or catheter-based angiography follow-up according to participating hospital's protocol will be performed at 12 months.
* Presence of stent fracture will be evaluated by plain radiography or fluoroscopy at 12 months.
* Quality of life by standardized questionnaires (at baseline \& at 1 \& 12 months)
Conditions
- Iliac Artery Disease
Interventions
- DEVICE
-
Epic stent (Boston Scientific)
Sponsors & Collaborators
-
Yonsei University
lead OTHER
Eligibility
- Min Age
- 19 Years
- Max Age
- 85 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2015-12-31
- Primary Completion
- 2021-01-31
- Completion
- 2021-01-31
Countries
- South Korea
Study Locations
More Related Trials
-
Korean Coronary Bifurcation Stenting (COBIS) Registry III
NCT03068494 ·Status: COMPLETED
-
Evaluation of the Valiant Captivia Physician Fenestrated Stent Graft System in Aortic Arch and Descending Thoracic Aorta Pathologies
NCT05479305 ·Status: RECRUITING ·Phase: NA
-
Intravascular Lithotripsy in High Risk Calcified Iliac Anatomy for Transfemoral TAVR
NCT05862558 ·Status: RECRUITING
-
Gangwon PCI Prospective Registry
NCT02038127 ·Status: RECRUITING
-
Evaluation of the Safety and Efficacy of the Multilayer Stent
NCT01756911 ·Status: COMPLETED ·Phase: NA
-
The Study to Evaluate the Safety and Efficacy of the Onyx Family
NCT06577896 ·Status: RECRUITING
-
Valiant Thoracic Stent Graft With the Captivia Delivery System in the Treatment of Descending Thoracic Aortic Diseases (VALIANT CAPTIVIA France)
NCT01775046 ·Status: COMPLETED
-
Safety and Efficacy of Express LD to Treat Stenosed or Occlusive Atherosclerotic Disease in Iliac Arteries
NCT00352222 ·Status: COMPLETED ·Phase: PHASE3
-
Prospective, Multicenter, Single-Arm Study of Aortic Arch Pathology Reconstruction
NCT07139912 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
An Investigator Initiated Trial to Evaluate the Safety and Feasibility of the DyNETIC-35 Stent for Iliac Lesions Via a Trans-radial Approach
NCT05372952 ·Status: COMPLETED
-
A Prospective Single-Arm Multicenter StuDy of the BarE TEmporary SPur StEnt System foR the tREatment of Vascular Lesions Located in the infrapoplitEal Arteries beLow the Knee (DEEPER REVEAL)
NCT05358353 ·Status: COMPLETED ·Phase: NA
-
Safety and Effectiveness of the Peripheral Balloon-Expandable Covered Stent System for Iliac Artery Stenosis/Occlusion. (SELECT)
NCT06605209 ·Status: RECRUITING ·Phase: NA
-
Post-market Registry in Patients With Iliac Aneurysm Undergoing Endovascular Stenting With the E-liac Stent Graft System
NCT02209194 ·Status: COMPLETED
-
Evaluation of the Efficacy and Safety of the Application of BeGraft Peripheral Stent Graft System
NCT04023370 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Prospective, Multi-center, Single-arm Study of the Auryon Laser System for Treatment of Below-the-Knee (BTK) Arteries
NCT05284240 ·Status: COMPLETED ·Phase: NA
-
IRIS-Onyx Cohort in the IRIS-DES Registry
NCT02593994 ·Status: ACTIVE_NOT_RECRUITING
-
Shockwave Coronary Lithoplasty Study
NCT02758379 ·Status: COMPLETED ·Phase: NA
-
Bare Metal Bifurcation Stent Clinical Trial in Humans
NCT00607321 ·Status: COMPLETED ·Phase: NA
-
Sealing Moderate Coronary Saphenous VEin Graft Lesions With Paclitaxel-Eluting Stents
NCT01223443 ·Status: TERMINATED ·Phase: PHASE4
-
Medical & Economical Evaluation of Fenestrated & Branched Stent-grafts to Treat Complex Aortic Aneurysms
NCT01168037 ·Status: COMPLETED
-
iHub Stent-Graft for Iliac Artery Aneurysms: Safety, Performance, and Effectiveness Study
NCT07005141 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Treatment of Popliteal Aneurysms With VIABAHN Stent Graft in Elective Surgery
NCT03996889 ·Status: UNKNOWN
-
Safety and Efficacy Study of Iliac Bifurcation Stent Graft System
NCT03686189 ·Status: UNKNOWN ·Phase: NA
-
The Study on the Safety and Efficacy of the G-iliac Iliac Bifurcation Stent Graft System
NCT06660927 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
A Prospective, Non-Randomized, Evaluation of Low-Risk Patients Undergoing Carotid Stenting With ANgiomax (Bivalirudin)
NCT01273350 ·Status: UNKNOWN ·Phase: NA