Assessing the Comparability of 2D and 4D Ultrasound Measurements

NCT02666911 · Status: WITHDRAWN · Phase: NA · Type: INTERVENTIONAL

Last updated 2017-08-07

No results posted yet for this study

Summary

Investigators will recruit 20 healthy volunteers between the ages of 18 and 80, who have no history of carpal tunnel syndrome or wrist injury. Images will be captured twice, first with the 2D transducer and then with the 4D transducer and compared to images captured with the new 4D transducer, using the same movement data analysis protocols. Investigators will also assess the inter and intrarater reliability of the 4D transducer images, by using two different sonographers, both trained in the technique, measuring the same blinded images on separate occasions, at least two weeks apart. The overall goal of this project is to assess the reliability, or reproducibility, of measurements in normal subjects using a novel 4D ultrasonographic method to characterize the subsynovial connective tissue (SSCT) and detect motion between SSCT, median nerve and tendon motion for the evaluation and diagnosis of patients with disorders affecting the carpal tunnel, especially carpal tunnel syndrome (CTS).

Conditions

  • Carpal Tunnel

Interventions

PROCEDURE

4D Ultrasound

Each subject will be imaged lying supine on imaging table with affected arm outstretched on Plexiglass board. An ultrasound scanner equipped with 15L8 linear array transducer will be set to depth of 20-25 mm with a 15MHz image acquisition frequency (for longitudinal and transverse imaging) and the same ultrasound machine equipped with 4D transducer will be used. Ultrasound evaluation will be performed by a sonographer trained in the pertinent image acquisition procedures. The image acquisition frame rate will be maintained at 70Hz, and the image compression will be set to low.

PROCEDURE

2D ultrasound

Each subject will be imaged lying supine on imaging table with affected arm outstretched on Plexiglass board. An ultrasound scanner equipped with 15L8 linear array transducer will be set to depth of 20-25 mm with a 15MHz image acquisition frequency (for longitudinal and transverse imaging) and the same ultrasound machine equipped with 4D transducer will be used. Ultrasound evaluation will be performed by a sonographer trained in the pertinent image acquisition procedures. The image acquisition frame rate will be maintained at 70Hz, and the image compression will be set to low.

Sponsors & Collaborators

Principal Investigators

  • Peter C. Amadio, M.D. · Mayo Clinic

Study Design

Allocation
NON_RANDOMIZED
Purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Max Age
80 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2018-01-31
Primary Completion
2019-01-31
Completion
2019-01-31
FDA Device
Yes