The Use of i/t Curve in Assessment of Phototherapy Effects
NCT02618642 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 60
Last updated 2020-01-13
Summary
Conventional electrodiagnostic examination is useful in daily physiotherapeutic practice. Nevertheless, the subjective assessment of muscle contraction and perceived current vibrations carries the risk of error and thus is a limitation of the method. Therefore, the use of the I/T curve coefficient was proposed in this study. This coefficient is the arithmetic mean of the electrical charge needed to trigger a sensory or motor reaction at different widths of the electrical pulse. PILER (Polychromatic Incoherent Low-Energy Radiation) light affects the sensory and motor excitability of the tissue. The resulting changes may depend on the colour of the filter used in the irradiations.
The study aimed to:
1. To evaluate changes in neuromuscular excitability occurring after PILER irradiation using filters of different colours.
2. To evaluate the usefulness of the I/T curve coefficient in neuromuscular excitation test.
60 healthy volunteers were assigned to one of four groups irradiated with: 1 - Piler light + red filter, 2 - Piler light + blue filter, 3 - Piler light without a filter, 4 - placebo.
Main Outcome Measures were plotting I/T curve coefficient for rectangular (■I/T coeff) and triangular (▲I/T coeff) pulses and the pressure pain threshold (PPT).
Conditions
- Nerve Disorders
Interventions
- RADIATION
-
Irradiations of the biceps brachii muscle with PILER light. The participants were randomized into 4 groups: group v - no filter/ group x - red filter/ group y - blue filter/ group z - placebo.
Biceps brachii examination was carried out before (examination 1) and after (examination 2) a series of 10 PILER light treatments. It included a traditional electrodiagnostic examination and the assessment of the pressure pain threshold (PPT). The electrodiagnostic examination of the muscle was performed using the unipolar stimulation method from the direct motor point. The passive electrode (6 cm x 6 cm) was attached to the side of the distal part of the forearm, and the distal edge of the electrode was adjacent to the proximal edge of the ulnar styloid process. The examination was performed with a Multitronic MT3 electrotherapy apparatus set. PPT at the direct motor point was determined using an algometer (Algometer commander TM ITECH Medical Industries). A head with a rubber jacket with a surface area of 0.5 cm2 was used to cause pressure pain. Pressure was exerted until the participant reported pain, at which time the force (lbs) marked by the algometer was recorded.
Sponsors & Collaborators
-
University of Rzeszow
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- BASIC_SCIENCE
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 21 Years
- Max Age
- 23 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2016-02-29
- Primary Completion
- 2019-07-31
- Completion
- 2019-07-31
More Related Trials
-
Study of LED Phototherapy for Musculoligamentous Lesions
NCT00382941 ·Status: COMPLETED ·Phase: NA
-
Effect of Light-emitting Diode (LED) Photobiomodulation Therapy on Muscular Fatigue in University Handball Athletes
NCT03972007 ·Status: UNKNOWN ·Phase: NA
-
Acute Effect of Phototherapy With Light Emitting Diode (LED) on Muscle and Pulmonary Oxygen Consumption on Diabetes Mellitus
NCT01889784 ·Status: UNKNOWN ·Phase: NA
-
Effect of Photobiomodulation on Healing of Venous Leg Ulcers
NCT07123285 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Pulsed Current Versus Russian Current Effects in Healthy Young Subjects.
NCT03796117 ·Status: COMPLETED ·Phase: NA
-
Effect of Photobiomodulation on the Treatment of Soft Tissue Traumatic Injuries
NCT04361773 ·Status: UNKNOWN ·Phase: PHASE1/PHASE2
-
Effect of Light Emitting Diode Therapy on Muscle Fatigue
NCT04367727 ·Status: UNKNOWN ·Phase: NA
-
Effect of Premodulated Current Versus Diadynamic Current On the Management of Tennis Elbow.
NCT05084664 ·Status: COMPLETED ·Phase: NA
-
Low-level Light Therapy on Treatment of Venous Ulcers Assesed by Nursing Outcome Classification (NOC)
NCT03229330 ·Status: COMPLETED ·Phase: NA
-
Effect of Photobiomodulation on Pain Control After Placement of Elastomeric Spacers.
NCT05924204 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
LED Photobiomodulation Improves Radial Artery Vascular Function in Vitro
NCT07041697 ·Status: COMPLETED ·Phase: NA
-
Comparative Analysis Between Electrical Muscle Activity In Water And Soil
NCT01969383 ·Status: UNKNOWN ·Phase: NA
-
Effects of Neuromuscular Electrical Stimulation Parameters on Torque, Fatigue, and Oxygen Extraction
NCT05061056 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Therapeutic Effects of LED (627 +/- 10nm) The Initial Phase of the Ankle Sprains Treatment
NCT02433964 ·Status: COMPLETED ·Phase: NA
-
Extracorporeal Shock Wave Versus Photobiomodulation Therapy for Chronic Ankle Instability
NCT07139288 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Practice of the Short Wave Diathermy (SWD) Application
NCT02379143 ·Status: COMPLETED
-
High Tone Power Therapy on Lumbosacral Radiculopathy Patients
NCT07305792 ·Status: COMPLETED ·Phase: NA
-
Effects of a Program of Physical Exercise and Electrotherapy on Muscle Strength in Subjects of the Fourth Age
NCT01086592 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
TENS for the Treatment of Pain and Respiratory Function Following Mastopexy With Augmentation
NCT06202794 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
The Effect of Pullsed Magnetic Field Induction on Improving the Forearm Tissue Muscle Performance
NCT02327806 ·Status: UNKNOWN ·Phase: NA
-
Acute Effects of Interferential Current on Edema, Pain and Muscle Strength in Patients With Distal Radius Fracture
NCT03438864 ·Status: COMPLETED ·Phase: NA
-
Effects of Light Emitting Diodes (LED) Therapy in Rugby Athletes
NCT03728439 ·Status: COMPLETED ·Phase: NA
-
Influence of Electrode Positioning and Current Type on Fatigue, Force and Discomfort
NCT04200677 ·Status: COMPLETED ·Phase: NA
-
Electromyographic (EMG) Biofeedback Training in Zone I-III Flexor Tendon Injuries
NCT04237415 ·Status: COMPLETED ·Phase: NA
-
Intramuscular Heating Rates of a Chattanooga Intelect XT Therapeutic Ultrasound