Radiofrequency Female External Genital Region: a Clinical Trial
NCT02611791 · Status: COMPLETED · Phase: PHASE2 · Type: INTERVENTIONAL · Enrollment: 42
Last updated 2015-11-23
Summary
OBJECTIVES: The aim of the study is to evaluate the clinical response of the non-ablative radiofrequency (RF) in the outcome cosmetic female external genital and its effect in the sexual function. METHODS: Single blind randomized controlled trial. Sample of 43 women (29 sexual active) with insatisfaction appearance of the external genitalia, 21 (14) in the study group and 22 (15) in the control group. The protocol consisted in 8 sessions of RF once a week. The instruments of evaluation were photo (taken before the first session and eight days after the last session), which were evaluated by the patient and by three health professional (that did not know the group); by the 3 points Likert scale (unsatisfied, unchanged, satisfied) and (worst, unchanged, improved). The sexual function was evaluated by the Female Sexual Function Index (FSFI) before and after, and analyzed by the T Test of Student. The patients' satisfaction and the health professionals' evaluation were analyzed by the chi-squared test and by binomial comparison inter-group and intra-group.
Conditions
- Dissatisfaction Appearance of the External Genitalia
Interventions
- DEVICE
-
Radiofrequency
The application of RF was through Tecatherap-VIP unit (VIP-Eletromedicina, Argentina) with bipolar method, using a gauntlet of 2cm, and the coupling electrode, which was located in the sacral region (fig x). For the application, participants were placed in a supine position with legs in lithotomy position, it was used water soluble gel for coupling and slide of the gauntlet. The application in external labia majora was made in the caudal-cranial direction, with constant movement and electrode lightly pressed. (fig) During the session, the heat level was monitored verbally and by infrared digital thermometer. The intensity was gradually increased, and at the time when the temperature reached values between 39-41ºC, the intensity was reduced two points and the procedure was maintained for two minutes.
- DEVICE
-
Radiofrequency - OFF
The treatment protocol for the control group was identical, differing only in relation to the RF equipment, which was turned off, but a water-soluble gel was used, heated by a resistor, preventing the patient from knowing to which group she belonged. Just the physiotherapist who performed the procedure knew which group the patient belonged to.
Sponsors & Collaborators
-
Centro de Atenção ao Assoalho Pélvico
lead OTHER
Principal Investigators
-
Patricia V Lordelo, PhD · Centro de Atenção ao Assoalho Pélvico - BAHIANA
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 60 Years
- Sex
- FEMALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2012-10-31
- Primary Completion
- 2013-12-31
- Completion
- 2014-06-30
More Related Trials
-
Safety and Efficacy of XP200 Radiofrequency Treatment of Wrinkles
NCT01795417 ·Status: COMPLETED ·Phase: NA
-
A Prospective Controlled Study to Evaluate the Safety and Effectiveness of Thermage® FLX Radiofrequency Treatment
NCT07187297 ·Status: RECRUITING ·Phase: NA
-
Radiofrequency and Pulsed Electromagnetic Field Treatment of Skin Laxity of the Mon Pubis, Labia and Vaginal Introitus
NCT02770287 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of the Efficacy of Fractional Radiofrequency for the Treatment and Reduction of Stretch Marks
NCT05097573 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of Fractional Radiofrequency for the Treatment and Reduction of Facial Wrinkles
NCT03831477 ·Status: COMPLETED ·Phase: NA
-
Fractional Radiofrequency for the Treatment and Reduction of Facial Wrinkles
NCT03776461 ·Status: COMPLETED ·Phase: NA
-
Study on the Safety, Efficacy of Home RF Cosmetic Instrument in the Treatment of Facial or Periorbital Wrinkles
NCT06441799 ·Status: COMPLETED ·Phase: NA
-
Comparison Of Aesthetic Techniques For Rejuvenation Of Genital Region: A Randomized Clinical Trial
NCT04998578 ·Status: RECRUITING ·Phase: NA
-
Clinical Evaluation of Fractional Bi-Polar Radio-Frequency for Symptoms of Vulvovaginal Atrophy
NCT05398172 ·Status: COMPLETED ·Phase: NA
-
CO2 Laser vs Lidocaine for Vestibulodynia in Premenopausal Women
NCT05336825 ·Status: COMPLETED ·Phase: NA
-
Efficacy and Safety of Polylevolactic Acid Injection Combined With 1565nm Non-ablative Fractional Laser in the Treatment of Striae Distensae
NCT05827913 ·Status: UNKNOWN ·Phase: NA
-
Clinical Study To Assess The Safety, Parameters And Efficacy For Procedures Using A Radiofrequency Device
NCT05166824 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Effects of Carboxytherapy and Radiofrequency on Skin Rejuvenation
NCT01981980 ·Status: COMPLETED ·Phase: NA
-
Prospective, Open-Label, Single-Center, Non-Comparative Study to Assess the Use of Pixel CO2 Laser System (FemiLift) in the Treatment of Vulvovaginal Atrophy (VVA) in Postmenopausal Female Subjects
NCT02747641 ·Status: COMPLETED ·Phase: NA
-
Clinical Assessment of Skin Tightening and Contour Change of Submental Tissue Using Bipolar Radiofrequency Microneedling
NCT04477187 ·Status: COMPLETED ·Phase: NA
-
Efficacy and Safety of 1565-nm Non-ablative Fractional Laser Versus Long-pulsed 1064-nm Nd:YAG Laser in the Treatment of Enlarged Facial Pores
NCT05360043 ·Status: UNKNOWN ·Phase: NA
-
Clinical Study of the CO2RE Laser Device Performance for Vaginal Atrophy Treatments
NCT02704741 ·Status: UNKNOWN ·Phase: NA
-
Clinical Evaluation of the Safety and Performance of FRF for the Treatment and Reduction of Acne Scarring
NCT04827680 ·Status: COMPLETED ·Phase: NA
-
POST-MARKETING CLINICAL STUDY to EVALUATE the EFFICACY and SAFETY of the VAGINAL FILLER MEDICAL DEVICE in CORRECTING THINNING of the GENITAL TISSUE of the LABIA MAJORA in WOMEN, RE-PROPORTIONING the FEMALE EXTERNAL GENITAL AREA and IMPROVING SEXUAL FUNCTION.
NCT06797167 ·Status: COMPLETED ·Phase: NA
-
Laser Treatment for Fresh Surgical Scars and Mature Scars
NCT01030198 ·Status: TERMINATED ·Phase: NA
-
Fractional Radiofrequency for Treatment of Acne Scars and Wrinkles
NCT05827510 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Thermal Outcome and Safety of Nuera Tight RF System
NCT05957029 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of Fractional Radiofrequency for the Treatment Acne Scarring
NCT03821324 ·Status: COMPLETED ·Phase: NA
-
Picosure Alexandrite Laser and Revlite Nd:Yag Laser for the Treatment of Unwanted Tattoos
NCT02110121 ·Status: COMPLETED ·Phase: NA
-
Fractional CO2 Laser System (Fraxel Repair Laser) Intended for Treatment of Perioral Rhytides/Wrinkles
NCT03715049 ·Status: COMPLETED ·Phase: NA