Comparison of Retinal Oxygenation and Retinal Vessel Diameters in Healthy Subjects and Patients With Diabetic Retinopathy or Retinal Vein Occlusion Between DVA and Oxymap

NCT02521116 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20

Last updated 2018-08-31

No results posted yet for this study

Summary

To date two different instruments are commercially available to measure retinal oxygen saturation and retinal vessel diameters: Dynamic Vessel Analyzer (DVA) and Oxymap. Retinal oxygen saturation analysis is based on spectroscopic evaluation of retinal fundus images. Up to now no data comparing both instruments for the measurement of retinal oxygen saturation and vessel diameter are available in the literature.

Study objectives: To compare retinal oxygenation and retinal vessel diameters in healthy subjects and patients with diabetic retinopathy or retinal vein occlusion between 2 commercially available systems (DVA, Oxymap T1)

Study design: Open pilot study

Study population:

30 healthy volunteers, age 18-80 years 30 type 2 diabetic patients with mild or moderate non-proliferative diabetic retinopathy, age 18-80 years 30 patients with retinal vein occlusion, age 18-80 years

Topically administered medication:

Tropicamide (Mydriaticum "Agepha"®, Agepha, Vienna, Austria), dose: 1-2 drops per study day for dilation of the pupil Oxybuprocainhydrochloride combined with sodium fluorescein (Thilorbin®, Alcon Pharma GmbH, Freiburg, Germany), dose: 1 drop in one eye for measurements of intraocular pressure Nonylacidvanillylamide combined with Nicotinic-acid--ß-butoxyethylester (Finalgon®, Boehringer Ingelheim RCV GmbH \& Co KG, Vienna, Austria): topical on the earlobe

Methods:

Dynamic vessel analyzer Oxymap T1 Blood pressure and pulse rate measurement Applanation tonometry Oxygen and carbon dioxide partial pressure measurement in arterialized blood from earlobe

Main outcome variables:

Difference of oxygen saturation of retinal vessels between DVA and Oxymap T1

The motive for this investigation is to compare data between 2 commercially available instruments for the measurement of retinal oxygen saturation and retinal vessel diameter in healthy subjects as well as in patients with ocular disease associated with altered retinal oxygenation. Comparative data from both systems are currently not available. Data from this study will allow the comparison of studies performed with different systems. All oxygen measurement procedures are non-invasive and painless. Hence, the risk/benefit ratio appears to be acceptable.

Conditions

Interventions

OTHER

Dynamic Vessel Analyzer

OTHER

Oxymap T1

Sponsors & Collaborators

  • Medical University of Vienna

    lead OTHER

Study Design

Allocation
NA
Purpose
OTHER
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Max Age
80 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2016-02-29
Primary Completion
2017-01-03
Completion
2018-02-28

Countries

  • Austria

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT02521116 on ClinicalTrials.gov