Simple Mechanical Device to Control Pressure in the Balloon of the Endotracheal Tube to Prevent Ventilator-acquired Pneumonia
NCT02514655 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 500
Last updated 2025-06-25
Summary
Hypothesis: Nosten® device is able to reduce the time of underinflated balloon and removes excess pressure. This device may thus reduce the risk of ventilator-acquired pneumonia (VAP) and early tracheal lesions resulting from intubation with decreased discomfort, morbidity, and nursing workload.
The main objective of the investigators is to show that Nosten® device is more effective than monitoring and manual inflation of the balloon of the tracheal tube to prevent VAP occurrence.
Conditions
- Mechanical Ventilation
- Tracheal Intubation
- Ventilator-acquired Pneumonia
- Intubation -Related Tracheal Lesions
Interventions
- DEVICE
-
Nosten® pressure control (it's not an antibiotic, but simple device)
One experimental group with the control of the cuff pressure by Nosten® device
- OTHER
-
Manual pressure control
One control group with the manual monitoring of the cuff pressure and inflation of the balloon
Sponsors & Collaborators
-
Assistance Publique - Hôpitaux de Paris
lead OTHER
Principal Investigators
-
Bruno MEGARBANE, MD, PhD · Assistance Publique - Hôpitaux de Paris
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2015-08-15
- Primary Completion
- 2015-08-15
- Completion
- 2026-12-31
Countries
- France
Study Locations
More Related Trials
-
Cuff Pressure Regulation Apparatus for Tracheal Intubation in Children
NCT04413318 ·Status: COMPLETED ·Phase: NA
-
Endotracheal Tubes for Prevention of Ventilator-associated Pneumonia
NCT01744483 ·Status: COMPLETED ·Phase: NA
-
Solid State vs. Balloon Esophageal Catheter for Estimation of Pleural Pressure
NCT05817968 ·Status: COMPLETED ·Phase: NA
-
A Comparison of Optimal PEEP Determination Guided by EIT and G5 Device in Moderate and Severe ARDS Patients
NCT03112512 ·Status: COMPLETED ·Phase: NA
-
Providing Optimal PEEP During Mechanical Ventilation for Obese Patients Using Esophageal Balloon
NCT03951064 ·Status: TERMINATED ·Phase: NA
-
Endotracheal Tubes to Prevent Ventilator-Associated Pneumonia
NCT03705286 ·Status: COMPLETED ·Phase: PHASE2
-
Efficiency of a Mechanical Device in Controlling Tracheal Cuff Pressure in Intubated Critically Ill Patients
NCT02109003 ·Status: COMPLETED ·Phase: NA
-
Visualization of Inspiratory Effort and Respiratory Mechanics to Promote Lung- and Diaphragm Protective Ventilation
NCT05459116 ·Status: RECRUITING ·Phase: NA
-
Distribution of Pulmonary Ventilation in Lateral Decubitus of Healthy Adults Under Non-Invasive Mechanical Ventilation
NCT06489509 ·Status: COMPLETED ·Phase: NA
-
Effect of Positive End-expiratory Pressure on Optimal Balloon Volume During Esophageal Pressure Monitoring
NCT02976844 ·Status: COMPLETED
-
Feasibility and Efficacy of Portable Non-invasive Negative Pressure Ventilation in Fontan Patients
NCT03251742 ·Status: COMPLETED ·Phase: PHASE1
-
ARDS Esophageal Balloon Pressure Changes With Positioning Study
NCT03120793 ·Status: TERMINATED
-
Cuffed Versus Uncuffed Tracheal Tubes in PICU (PICU-BG-TT Study)
NCT03129893 ·Status: COMPLETED
-
PEEP as Rescue Therapy for Asthmatics With Elevated BMI
NCT02696980 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Study of Variations of Pleural and Esophageal Pressures Under Mechanical Ventilation After Lung Transplantation
NCT03179644 ·Status: COMPLETED ·Phase: NA
-
Endotracheal Tube Intracuff Pressure and Leak Around the Cuff During Retractor Placement for Adenotonsillectomy
NCT02640248 ·Status: WITHDRAWN
-
Pulmonary Expansion Device in Tracheostomized Patients Therapies in Tracheostomized Patients
NCT06075381 ·Status: NOT_YET_RECRUITING ·Phase: PHASE2
-
Lung Volume Change Between Noninvasive Positive Pressure Ventilation by Nasal Pillow and High Flow Nasal Cannula
NCT02292992 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Reduced Cuff-pressure of the Laryngeal Tube Under General Anesthesia
NCT02300337 ·Status: COMPLETED ·Phase: NA
-
GO2 PEEP Study: Bidirectional Oxygenation Valve in Postoperative Atelectasis
NCT04253834 ·Status: COMPLETED ·Phase: NA
-
To Compare Endotracheal Tube (ET) With Subglottic Suction Drainage and Standard ET in the Incidence of VAP
NCT03101202 ·Status: COMPLETED ·Phase: NA
-
Continuous Measurement of Intratracheal Pressure
NCT00866255 ·Status: COMPLETED ·Phase: NA
-
Endotracheal Tube Cuff Pressures in Ventilated Patients
NCT02950519 ·Status: COMPLETED ·Phase: NA
-
EIT Assessment of Lung Volume and Tidal Distribution: A Comparison of Non-Invasive Ventilation Devices
NCT02930174 ·Status: COMPLETED ·Phase: NA
-
Continuous Control of Polyurethane Tracheal-cuff Pressure: Efficiency of a Pneumatic Device
NCT01351259 ·Status: COMPLETED ·Phase: PHASE4