Cardiovascular Response to Orthostatic Fractional Gravity
NCT02508818 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 18
Last updated 2015-07-27
Summary
There are no equivalent experiment setups to create comparable changes of gravitation such as during parabolic flights. To determine the initial orthostatic responses of the cardiovascular system under the gravitational conditions of mars and moon is an essential step for a better understanding of 1) the fundamental functions of the human cardiovascular system (basic research) 2) specific impact of partial-g on the human heart, lungs and vessels in a spaceflight-context 3) approaches for countermeasure development against orthostatic intolerance on moon and mars (applied research).
Non-invasive measurement methods will be used to achieve the cardiovascular key values of the study: stroke volume (SV) and cardiac output determination by pulse contour analysis, impedance cardiography and inert gas rebreathing, beat-to-beat finger blood pressure measurement, heart rate and heart rate variability determination by ECG. All of these methods have proven their accuracy during parabolic flights. Nevertheless pulse contour analysis and impedance cardiography are known to provide only relative SV and CO values. Thus inert gas rebreathing gives us the possibility to calibrate these stroke volumes and cardiac outputs to absolute values. Success of this procedure was shown during former parabolic flights.
Conditions
- Healthy Volunteers
Interventions
- OTHER
-
Parabolic flight
- OTHER
-
Cardiovascular measurements
Sponsors & Collaborators
-
University Hospital, Caen
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- BASIC_SCIENCE
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 55 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2011-06-30
- Primary Completion
- 2015-11-30
Countries
- France
Study Locations
More Related Trials
-
Non-contact Blood Pressure and SpO2 Measurement Based on Image Sensor
NCT06204822 ·Status: RECRUITING
-
Early Identification of Clinical Deterioration Using a Wearable Monitoring Device
NCT04220359 ·Status: COMPLETED
-
Pilot Study to Evaluate the Somnotouch Device to Quantify Spontaneous Baroreflex Sensitivity
NCT02650232 ·Status: COMPLETED ·Phase: NA
-
Safety and Performance Study of the MultiSense® Ambulatory Telemonitoring System for Non-critical Patient Management
NCT05357729 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Impact of the SMART ANGEL ™ Device on Follow-up at Home Following Major or Intermediate Outpatient Surgery
NCT04068584 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Aging, Autonomic Nervous System Activity and Cardiovascular Events
NCT00759304 ·Status: ACTIVE_NOT_RECRUITING
-
Necklace-Shaped Sensor for Non-Invasive Remote Monitoring of Vitals
NCT02337790 ·Status: COMPLETED
-
Use of the ECG Watch in Palpitation Assessment: Feasibility Study
NCT07121816 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of the BodyGuardian End-to-end Remote Monitoring Platform in an Outpatient Heart Failure Population
NCT01975402 ·Status: COMPLETED
-
Evolution of the Relationship Between Central and Peripheral Arterial Wave Velocities as a Function of Age
NCT06742775 ·Status: NOT_YET_RECRUITING
-
Clinical Impact of Non-invasive Hemodynamic Monitoring
NCT02950597 ·Status: COMPLETED
-
Assessment of the BodyGuardian Remote Monitoring Platform in Elderly Healthy Subjects
NCT01808053 ·Status: COMPLETED
-
Diaphragmatic Breathing and Heart Rate Variability Training for Improving Hypertension in Fragile X Associated Tremor/Ataxia
NCT03816540 ·Status: COMPLETED ·Phase: PHASE3
-
Monitoring Subjects With Fluid-Management Issues In the Home Environment
NCT02190877 ·Status: COMPLETED
-
A Novel System to Detect Falls in Real-life Conditions
NCT02835248 ·Status: COMPLETED
-
Cardiovascular Assessment in Patient Recovered From COVID-19 and Recovery of Autonomic Nervous System in Association With the Severity of the Disease
NCT05081362 ·Status: COMPLETED ·Phase: NA
-
Validity and Reliability of a Clinical Method for Assessment of Cardiorespiratory Fitness Using Seismocardiography
NCT05356871 ·Status: COMPLETED
-
Prospective Registry on User Experience With The Mapping System For Ablation Procedures
NCT02698670 ·Status: COMPLETED
-
Image-based Remote Monitoring in Cardiac Surgery Patients
NCT06099327 ·Status: COMPLETED
-
Applying Artificial Intelligence to the 12 Lead ECG for the Diagnosis of Pulmonary Hypertension: an Observational Study
NCT05942859 ·Status: ENROLLING_BY_INVITATION
-
Prediction Models for Cardiovascular and Neurocognitive Disease Risk in the General Population
NCT05951764 ·Status: RECRUITING
-
Safety Acceptability and Benefits of Tracking Cardiac Pacemakers by Carelink Express
NCT03140150 ·Status: TERMINATED ·Phase: NA
-
Indirect Evaluation of Lithium Level in Blood Using Non-invasive Sweat Biosensors
NCT04186507 ·Status: UNKNOWN
-
Pulmonary Artery DenerVation Clinical Study Using the Gradient Denervation System in Heart Failure Patients With Pulmonary Hypertension Group 2 (PreVail-PH2 OUS Study)
NCT06495970 ·Status: RECRUITING ·Phase: NA
-
Establishing a Non-invasive Method to Measure Your Heart's Performance
NCT02240979 ·Status: COMPLETED