Near Infrared Spectroscopy in Cyanotic Congenital Heart Disease
NCT02417259 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 40
Last updated 2018-04-03
Summary
We are conducting a prospective cohort study of 20 children with cyanotic congenital heart disease who are admitted for cardiac surgery. We will record cerebral and somatic near infrared spectroscopy (NIRS) at two sites - forehead and flank regions using the Covidien INVOS™ 5100C Cerebral / Somatic Oximeter. The monitoring will begin one hour pre-operatively (baseline) and continue until 48hours post-operatively. We will also take measurements prior to discharge from hospital. Baseline demographics, physiological and laboratory variables will be recorded. Clinical outcome variables including mortality, duration of intensive care unit (ICU) stay, duration of mechanical ventilation, inotropic support and feed tolerance will also be recorded.
Conditions
- Congenital Heart Defects
Sponsors & Collaborators
-
Covidien Private Limited
collaborator UNKNOWN -
KK Women's and Children's Hospital
lead OTHER_GOV
Eligibility
- Min Age
- 1 Day
- Max Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2015-07-31
- Primary Completion
- 2016-06-30
- Completion
- 2018-04-30
Countries
- Singapore
More Related Trials
-
Validation of Near Infrared Spectroscopy (NIRS) During Heart-Lung Bypass in Children
NCT00745394 ·Status: WITHDRAWN
-
Use of Near Infrared Spectroscopy to Measure Intracranial ScvO2
NCT01746576 ·Status: COMPLETED ·Phase: NA
-
Cardiac Function as Measured by Non-invasive Electrical Velocimetry Cardiac Monitor in Hospitalized Children
NCT01030445 ·Status: COMPLETED
-
Validation of Brain Oxygenation Monitor on Pediatric Patients
NCT00849940 ·Status: TERMINATED ·Phase: NA
-
Cerebral Oximetry in Newborns - Comparing INVOS 5100c and OxyPrem vs. 1.2
NCT01771601 ·Status: COMPLETED
-
Cerebral Oxygenation, Different Measurement Points and Their Correlation in Pediatric Population
NCT03136952 ·Status: COMPLETED
-
Cerebral Oximetry in Newborns - Comparing INVOS 5100 and FORE-SIGHT Cerebral Oximeters
NCT01665287 ·Status: COMPLETED
-
Noninvasive Determination of Cerebral Tissue Oxygenation in Pulmonary Hypertension
NCT01463514 ·Status: COMPLETED ·Phase: NA
-
Central Venous Saturation (ScvO2) Monitoring in Pediatric Patients Undergoing Cardiac Surgery
NCT00883922 ·Status: COMPLETED
-
Using Near-infrared Spectroscopy (NIRS) Monitor to Noninvasively Evaluate Hepatic Venous Saturation
NCT01891188 ·Status: COMPLETED
-
Near Infrared Spectroscopy and Transcutaneous Oxygen Pressure in Critical Limb Ischemia Before and After Treatment
NCT01459341 ·Status: COMPLETED
-
Cerebral Tissue Oxygenation Values in Newborns Measured Using Laser and LED NIRS Oximeters
NCT01496027 ·Status: COMPLETED
-
Clinical Assessment of Nonin 7600 Near Infrared Spectroscopy (NIRS) Tissue Oximetry During Cardiovascular Surgery
NCT01289470 ·Status: COMPLETED
-
Cerebral Circulation in Critically Ill Children
NCT03731104 ·Status: COMPLETED
-
Effects of Cerebral Oxygen Saturation on Neuropsychological Outcomes
NCT00151307 ·Status: TERMINATED ·Phase: PHASE2/PHASE3
-
Noncontact Vital Sign Monitoring Using IR-UWB Radar
NCT03622996 ·Status: UNKNOWN
-
Cardiovascular Response to Maternal Hyperoxygenation in Fetal Congenital Heart Disease
NCT03147014 ·Status: UNKNOWN ·Phase: NA
-
Oxygen Consumption-based Assessments of Hemodynamics in Neonates Following Congenital Heart Surgery (Oxy-CAHN Study)
NCT02184169 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Peripheral Pulse Oximetry Versus Arterial Co-oximeter in Children With Cyanotic Heart Disease
NCT02237014 ·Status: COMPLETED
-
Correlation of Cerebral Oxygen Saturation Measured From 2 Sensor Sites: Forehead vs. Temporal
NCT05087836 ·Status: COMPLETED
-
Functional Near Infrared Spectroscopy in Adult Surgery
NCT04574440 ·Status: RECRUITING
-
Cerebral Oxygenation and Burst Suppression
NCT04206683 ·Status: COMPLETED
-
Validation of Capnodynamic Assessment of Mixed Venous Oxygen Saturation
NCT04885699 ·Status: COMPLETED
-
The Performance of Pulse Oximeters in Pediatric Patients With Low Oxygen Saturation Levels
NCT00854048 ·Status: COMPLETED
-
Clinical Performance Evaluation of Pediatric and Neonatal Low Saturation Oximetry Sensors
NCT00843401 ·Status: COMPLETED