Quantitative Prostate Cancer Contrast-enhanced Ultrasound
NCT02295449 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 130
Last updated 2018-08-31
Summary
Background: Bracco has released the VueBoxTM-Prostate software, aimed at distinguishing prostate cancer from prostate benign peripheral zone (PZ) at contrast-enhanced ultrasound (CEUS) using SonoVue® as contrast agent.
The software analyses the ascending phase of enhancement (wash-in) and calculates the mode and the dispersion (sigma) of the wash-in rate in a given region of interest. The diagnosis of cancer is based on the combination of these two parameters.
The main objective of the study is to evaluate the diagnostic value of the VueBoxTM-Prostate software in distinguishing prostate cancer from normal PZ at contrast-enhanced ultrasound (CEUS).
The secondary objective is to evaluate the diagnostic value of the wash-out rate, the time to peak, the transit time and the area under the enhancement curve (parameters not used by the VueBoxTM-Prostate software) in distinguishing prostate cancer from prostate benign peripheral zone at contrast-enhanced ultrasound (CEUS).
The study will enroll patients referred for prostate biopsy. The US transrectal probe will be inserted and the local anesthesia performed as per the institution's standard of care protocol. Then, the biopsy operator will choose an axial plane likely to contain cancer (e.g. based on MRI or Digital rectal examination results). Half a vial (2.4 ml) of SonoVue® will then be injected and the ultrasound enhancement of this plane will be recorded during 2 minutes while the biopsy gun is already in place. Then, the biopsy will be taken while the recording is still on, so that it will be possible to calculate quantitative enhancement parameters at the exact location of the biopsy.
Then, the operator will choose a plane that is likely not to contain cancer in the opposite prostate lobe and the same process will be repeated with injection of the second half of the vial.
The rest of the biopsies will be performed as per the institution's standard of care protocol.
The two recordings will be sent to Bracco's Research center in Geneva in order to:
* Predict the biopsy result (cancer vs benign) based on the VueBoxTM-Prostate software results
* Calculate the wash-out rate, the time to peak, the transit time and the area under the enhancement curve at the biopsy location.
The two biopsy samples performed after the injection of SonoVue® (as the rest of the biopsy samples) will be processed and analysed at the institution's department of Pathology and their results will be blinded to the Bracco's Research center.
The correlation between the biopsy results, the VueBoxTM-Prostate software results and the wash-out rate, time to peak, transit time and area under the enhancement curve will be performed by the study investigator.
In total, 130 patients will be included (hypotheses of 20% of malignant biopsy cores and of an area under the ROC curve of 0.85 for the VueBoxTM-Prostate software).
Conditions
Interventions
- DEVICE
-
biopsy sample performed after the SonoVue® injection
Sponsors & Collaborators
-
Hospices Civils de Lyon
lead OTHER
Principal Investigators
-
Olivier ROUVIERE, Professor · Hospices Civils de Lyon
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Sex
- MALE
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2015-06-09
- Primary Completion
- 2020-06-30
- Completion
- 2020-06-30
Countries
- France
Study Locations
More Related Trials
-
Targeted Prostate Biopsy Using a Novel MRI-Ultrasound Fusion Device
NCT02524860 ·Status: UNKNOWN ·Phase: NA
-
Detection of High Grade Prostate Cancer With Subharmonic Ultrasound Imaging, A Pilot Study
NCT02967458 ·Status: COMPLETED ·Phase: PHASE2
-
Feasibility Study of Ultrasound Elastography Detecting Prostate Cancer
NCT03077126 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the PI-RADS v2.1 Score Using Multiple Readers
NCT04299997 ·Status: COMPLETED
-
Artificial Intelligence & Prostate Cancer
NCT06298305 ·Status: COMPLETED
-
MRI / Ultrasound Fusion With Contrast-Enhanced Ultrasound Guidance
NCT02233725 ·Status: UNKNOWN ·Phase: PHASE1
-
Pivotal Study of MRI-guided Transurethral Ultrasound Ablation in Patients With Localized Prostate Cancer
NCT02766543 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
ClariCore Optical Biopsy System Used in TRUS (Trans-Rectal Ultrasound)-Guided Prostrate Biopsy
NCT02928640 ·Status: UNKNOWN ·Phase: NA
-
Detection of ISUP≥2 Prostate Cancers Using Multiparametric MRI: Prospective Multicenter Comparison of the PI-RADS Score and an Artificial Intelligence System
NCT04732156 ·Status: RECRUITING ·Phase: NA
-
An AI Platform Integrating Imaging Data and Models, Supporting Precision Care Through Prostate Cancer's Continuum
NCT05384002 ·Status: COMPLETED
-
Quantification of Contrast Enhanced Ultrasound (CEUS) in the Detection of Prostate Cancer
NCT01481441 ·Status: TERMINATED ·Phase: NA
-
Multi-Center Trial of High-resolution Transrectal Ultrasound Versus Standard Low-resolution Transrectal Ultrasound for the Identification of Clinically Significant Prostate Cancer
NCT02079025 ·Status: COMPLETED ·Phase: NA
-
Targeted And Perilesional Or Systematic Biopsy In Prostate Cancer
NCT07296042 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Semi-automatic Download of Prostate Biopsy Cores While Keeping the Orientation, Unfolding and Unity of the Sample
NCT01692405 ·Status: COMPLETED ·Phase: NA
-
Assessment of Prostate MRI Before Prostate Biopsies
NCT02485379 ·Status: COMPLETED ·Phase: NA
-
A Pilot Trial of Sonoelastography for Planning Tumor-targeted Prostate Biopsy
NCT01748890 ·Status: TERMINATED ·Phase: NA
-
Predicting Location and Extent of Prostate Cancer Using Micro-Ultrasound Imaging
NCT04981223 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Copper Cu 64 TP3805 PET in Detecting Prostate Cancer in Patients With Persistently Elevated PSA
NCT02989623 ·Status: COMPLETED ·Phase: NA
-
PRostate Evaluation for Clinically Important Disease: Sampling Using Image-guidance Or Not?
NCT02380027 ·Status: COMPLETED ·Phase: PHASE3
-
Cancer Diagnosis by Multiparametric UltraSound of the Prostate
NCT02712684 ·Status: UNKNOWN
-
Ultrasound Based Transperineal Robotic Biopsy of the the Prostate
NCT01102361 ·Status: UNKNOWN ·Phase: PHASE1/PHASE2
-
Ultrasound-Based Imaging Using the Aixplorer System in Diagnosing Prostate Cancer in Patients Undergoing Biopsy
NCT03013413 ·Status: COMPLETED ·Phase: NA
-
European Multicenter Validation of PCaVision: A Head-to-Head Diagnostic Accuracy Study Comparing Multiparametric Transrectal Ultrasound to MRI for Clinically Significant Prostate Cancer Detection
NCT06935487 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Using Ultrasound Spectrum Analysis (USA) to Guide Dose Escalated Prostate Brachytherapy
NCT01227642 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Motorised Probe Holder Assisting Prostate Biopsies
NCT02132975 ·Status: COMPLETED ·Phase: NA