Evaluation of Safety and Tolerability of Nitric Oxide Impregnated Urinary Catheters

NCT02277171 · Status: COMPLETED · Phase: PHASE1 · Type: INTERVENTIONAL · Enrollment: 15

Last updated 2015-12-24

No results posted yet for this study

Summary

According to the World Health Organization, hundreds of millions of patients are affected by health-care associated infections worldwide each year, resulting in prolonged hospital stays, long-term disabilities, deaths, and financial losses for health systems. The most common hospital-acquired infection is Urinary Tract Infection (UTI), accounting for almost 40% of all nosocomial infections. Most hospital-acquired UTIs are associated with catheterization. In fact, urinary catheter-related bacteriuria is the most common health care associated infection worldwide. Catheter-associated UTI (CAUTI) develops following adhesion of planktonic bacteria to the surface of the catheter and colonization, creating a persistent environment called a biofilm. The nature of biofilm structure together with the physiological attributes of biofilm organisms confers an inherent resistance to various antimicrobial agents such as antibiotics, disinfectants or germicides, augmenting the potential of these pathogens to cause infections in catheterized patients.

Nitric oxide (NO) is a naturally-produced gas molecule with broad-spectrum antimicrobial activity. NO is used in the clinics to treat pulmonary hypertension in neonates and adults. Studies have shown that low-dose NO is associated with prevention of biofilm formation, biofilm dispersal and elimination of bacteria. It is suggested that NO prevents bacteria attachment to catheter surfaces and inhibits biofilm formation in a mechanism involving reduction and modification of proteins that mediate cell-substrate and cell-cell interactions.

The investigators team, using a proprietary technology impregnate urinary catheters with NO (i.e. NO-impregnated catheters). These catheters release low concentration of NO following exposure to urine over a 14-day period. In vitro studies showed that NO-impregnated catheters prevent bacterial colonization and biofilm formation of Escherichia coli on exterior and luminal surfaces of the catheters. In addition, NO released from these catheters is able to eradicate up to 4log colony forming unit/ml of bacteria within the surrounding media. Moreover, NO-impregnated catheters exhibit superior performance compared to silver-coated catheters, and similar anti-infective properties compared to antibiotic-coated catheters.

Primary objectives: To assess the safety and tolerability of NO-impregnated catheters in patients older than 18 years old undergoing radical prostatectomy and catheterized for 7-14 days.

Conditions

Interventions

DEVICE

Nitric Oxide impregnated catheter

Patients undergoing radical prostatectomy will be catheterized for 7-14 days with Nitric Oxide impregnated Foley catheters

Sponsors & Collaborators

  • Rabin Medical Center

    collaborator OTHER
  • Enox Israel Ltd

    lead INDUSTRY

Principal Investigators

  • David Greenberg, prof. · ENOX

Study Design

Allocation
NA
Purpose
PREVENTION
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Max Age
80 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2014-12-31
Primary Completion
2015-06-30
Completion
2015-09-30

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT02277171 on ClinicalTrials.gov