Comparison of the Sensitivity and Specificity of Acoustic Angiography to the Sensitivity and Specificity of Conventional Ultrasound

NCT02175628 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 23

Last updated 2019-08-05

Study results available
· View outcomes & findings →

Summary

Purpose: This study will evaluate a new ultrasound imaging technology called acoustic angiography. Acoustic angiography uses an ultrasound contrast agent, already FDA approved for use in cardiology, to enhance imaging of blood vessels. Since acoustic angiography uses ultrasound, and not x-rays, the patient is not exposed to ionizing radiation, unlike traditional angiography and mammography. Specific goals will be to evaluate the quality of the images provided by acoustic angiography in the human breast, and furthermore to evaluate whether or not acoustic angiography provides additional diagnostic information over traditional ultrasound which could provide an improvement in assessing breast lesions. Specifically, this additional diagnostic information will hopefully enable us to reduce false positive tests and discriminate lethal cancers from non-lethal disease.

Participants: The investigators are recruiting 60 patients from the UNC Breast Clinic who are undergoing core needle biopsy or surgical biopsy (BIRADS 4 and 5 breast lesions).

Procedures (methods): Acoustic Angiography imaging will be performed in conjunction with standard diagnostic imaging, including b-mode ultrasound . Then, a reader study will be conducted to compare these modalities. Finally, the images will be analyzed with image processing techniques to determine quantitative metrics exhibited by the blood vessel morphology in the images. These metrics will be utilized to develop a "malignancy score" equation to predict malignancy of a lesion.

Conditions

  • Signs and Symptoms

Interventions

DEVICE

Acoustic Angiography

Acoustic angiography imaging involves a research high frequency ultrasound scanner (VisualSonics Vevo 770) and a prototype transducer as well as conventional b-mode ultrasound to guide the location of the imaging. The conventional ultrasound will be conducted just prior to the acoustic angiography for localization. The imaging also requires administration of Definity ultrasound contrast agent. Acoustic angiography imaging will be performed by trained medical personnel using mild compression to eliminate motion. Total imaging time is estimated to be less than 15 minutes. All image data will be de-identified and transferred for off-line analysis based on a study ID. The research images will NOT be interpreted or analyzed for clinical decisions related to the patient.

Sponsors & Collaborators

  • National Cancer Institute (NCI)

    collaborator NIH
  • UNC Lineberger Comprehensive Cancer Center

    lead OTHER

Principal Investigators

  • Yueh Lee, MD, PhD · University of North Carolina, Chapel Hill

Study Design

Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
FEMALE
Healthy Volunteers
No

Timeline & Regulatory

Start
2014-06-30
Primary Completion
2018-06-30
Completion
2018-06-30

Countries

  • United States