Non-invasive Brain Pressure Monitoring After Trauma or Hemorrhage

NCT02172703 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 11

Last updated 2015-07-08

No results posted yet for this study

Summary

Introduction: Increased intracranial pressure (ICP) is considered to be the most important intracranial mechanism causing secondary injury in patients admitted after acute traumatic brain injury (TBI) and intracranial haemorrhage (ICB) including subarachnoid haemorrhage (SAH). Currently, ICP can be measured and monitored only using invasive techniques. The two ICP measurement methods available - intraventricular and intraparenchymal - require both a neurosurgical procedure in order to implant the catheter and probes within the brain. The invasiveness of current methods for ICP measurement limits the diagnoses reliability of many neurological conditions in which intracranial hypertension is a treatable adverse event. A reliable, accurate and precise non-invasive method to measure ICP would be of considerable clinical value, enabling ICP measurement without the need of a surgical intervention.

Aim:

The aim of this study is to validate a novel non-invasive ICP measurement device by comparing its measurement with the "gold standard" invasive ICP-measurement by intracranial probe. The device used in this study has been been developed in the Telematic Science Laboratory at the Kaunas University of Technology, Lithuania.

Methods:

The non-invasive ICP measurement method will be assessed prospectively using repeatable simultaneous non-invasive and invasive (standard with intracranial probe) ICP measurements on patients presenting with TBI and SAH. The device method is based on two-depth transcranial doppler (TCD) technique for simultaneously measuring flow velocities in the intracranial and extracranial segments of the ophthalmic artery (OA). The intracranial segment of the OA is compressed by ICP and the extracranial segment of the OA is compressed by the pressure Pe externally applied by the device. Two-depth TCD device is used as an accurate indicator of the balance point (Pe = ICP) when the measured parameters of blood flow velocity waveforms in the intracranial and extracranial segments of OA are identical. The device has the same ultrasound transmission parameters as existing TCD devices and meets all patient safety criteria.

Conditions

  • Traumatic Brain Injury (TBI)
  • Subarachnoid Hemorrhage (SAH)

Interventions

DEVICE

Non-invasive ICP measurement device

The non-invasive ICP measurement device used in this study has been developed in the Telematic Science Laboratory at the Kaunas University of Technology, Lithuania. The non-invasive method is based on two-depth TCD technique for simultaneously measuring flow velocities in the intracranial and extracranial segments of the ophthalmic artery (OA).

Sponsors & Collaborators

  • Kaunas University of Technology

    collaborator OTHER
  • Javier Fandino, MD

    lead OTHER

Principal Investigators

  • Javier Fandino, M.D. · Department of Neurosurgery, Kantonsspital Aarau, Aarau, Switzerland

Study Design

Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2014-02-28
Primary Completion
2015-07-31
Completion
2015-07-31

Countries

  • Switzerland

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT02172703 on ClinicalTrials.gov