Performance of a Single-piece Toric Acrylic Intraocular Lens
NCT02155959 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 30
Last updated 2014-06-04
Summary
Abstract Purpose: To evaluate the visual performance and rotational stability of the Tecnis Toric one-piece IOL (AMO, USA) during the first 3 post-operative months Design: Prospective single center study Setting: VIROS - Vienna Institute for Research in Ocular Surgery, a Karl Landsteiner Institute, Hanusch Hospitel, Vienna, Austria Methods: In this prospective study patients with age-related cataract and corneal astigmatism of 1.0 to 3.0 D measured with the IOL-Master 500 (Carl Zeiss Meditec AG, Germany) were included. Pre-operatively, rotating Scheimpflug scans (Pentacam HR, Oculus, Germany) were performed and the cornea was marked in the sitting position at the slit lamp. Patients recieved a single-piece toric hydrophobic acrylic IOL (Tecnis Toric, AMO, USA). Immediately and 3 months after surgery retroillumination photographs were taken to assess the rotational stability of the IOL. Additionally, Autorefraction (Topcon, USA), subjective refraction, uncorrected and distance corrected visual acuity, keratometry, Scheimpflug and ocular wavefront (WASCA, Carl Zeiss Meditec AG, Germany) measurements were performed at the 3 months follow-up.
Conditions
- Cataract
- Corneal Astigmatism
Interventions
- DEVICE
-
toric intraocular lens
toric intraocular lens
Sponsors & Collaborators
-
Prim. Prof. Dr. Oliver Findl, MBA
lead OTHER
Principal Investigators
-
Oliver Findl, MD, MBA · Vienna Institute for Research in Ocular Surgery
Eligibility
- Min Age
- 21 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-03-31
- Primary Completion
- 2012-12-31
- Completion
- 2012-12-31
More Related Trials
-
Visual Performance of an Extended Depth of Focus IOL in an Emmetropic or Monovision Modality
NCT06624826 ·Status: RECRUITING ·Phase: NA
-
Rayner Toric IOL Rotational Stability
NCT02393313 ·Status: UNKNOWN ·Phase: NA
-
Visual Performance Following Implantation of Presbyopia Correcting IOLs
NCT04907955 ·Status: COMPLETED ·Phase: NA
-
Comparison of Clinical Outcomes of Toric Intraocular Lens
NCT03085901 ·Status: COMPLETED ·Phase: NA
-
Use of Toric Intraocular Lens to Neutralize Keratometric Astigmatism
NCT00925886 ·Status: TERMINATED ·Phase: NA
-
Assessment of Visual and Refractive Results and Rotational Stability of the TECNIS® Eyhance Toric II 1-piece Posterior Chamber Lens in Patients With Astigmatism Undergoing Cataract Surgery
NCT05144308 ·Status: TERMINATED ·Phase: NA
-
A Comparison of Visual Function After Bilateral Implantation of Presbyopia Correcting Intraocular Lenses
NCT01299155 ·Status: COMPLETED ·Phase: NA
-
Diurnal Changes of the Cornea - a Pilot Study
NCT02155556 ·Status: COMPLETED
-
Evaluation of the Rotational Stability of the Tecnis Toric II IOL
NCT04327518 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
NCT03050697 ·Status: COMPLETED ·Phase: NA
-
Rotational Stability After Nanoflex Collamer Toric Intraocular Lens Implantation in Astigmatic Patients
NCT02412215 ·Status: UNKNOWN ·Phase: NA
-
Comparison Between Bilateral Multifocal Intraocular Lenses and Pseudophakic Monovision
NCT02155348 ·Status: UNKNOWN ·Phase: NA
-
Tilt Prediction of Clareon Intraocular Lens
NCT06595693 ·Status: COMPLETED
-
Toric IOL vs Non-toric IOL With LRI for Corneal Astigmatism
NCT03633851 ·Status: UNKNOWN ·Phase: NA
-
Astigmatism Management in Cataract Surgery With the AcrySof Toric Intraocular Lens
NCT01075542 ·Status: COMPLETED ·Phase: NA
-
Comparison of 2 Diffractive Trifocal IOLs
NCT03748381 ·Status: UNKNOWN ·Phase: NA
-
Prospective Multicenter Clinical Study on the Visual and Refractive Outcomes and Safety Outcomes Following Implantation of an AddOn Intraocular Lens in Previously Pseudophakic Eyes
NCT05596682 ·Status: UNKNOWN
-
A Prospective, Randomized Clinical Study of Two Phakic Toric Implantable Lenses
NCT06839898 ·Status: RECRUITING ·Phase: NA
-
Clinical Evaluation of Toric Intraocular Lens Made by Aurolab
NCT01396616 ·Status: UNKNOWN ·Phase: PHASE4
-
Evaluation of an Hydrophilic Acrylic Intraocular Lens
NCT04793789 ·Status: COMPLETED
-
Rotational Stability Analysis of a Toric Monofocal IOL
NCT04933487 ·Status: COMPLETED ·Phase: NA
-
Study on Visual Performance of a Monofocal Intraocular Lens
NCT04740788 ·Status: COMPLETED
-
Comparison of Aspheric Toric Intraocular Lenses for Micro-monovision
NCT05506553 ·Status: UNKNOWN ·Phase: NA
-
Observational Prospective Clinical Investigation on Monofocal Toric Intraocular Lens
NCT06250855 ·Status: COMPLETED
-
Prospective Evaluation of the Tecnis Symfony Intraocular Lens (IOL)
NCT03579368 ·Status: UNKNOWN ·Phase: NA