Trial Outcomes & Findings for Volume Restriction in Esophageal Carcinoma Surgery: Randomized Clinical Trial (NCT NCT02033213)

NCT ID: NCT02033213

Last Updated: 2014-05-26

Results Overview

At the given time point, 10 minutes after beginning of the Lewis Tanner procedure and 6 hours after, arterial oxygen partial pressure (PaO2), inspired oxygen fraction (FiO2), and the PaO2/FiO2 ratio will be measured. The results of Pa02/FiO2 ratio will be compared between two groups for each time point separately.

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

16 participants

Primary outcome timeframe

10 minutes, 6 hours

Results posted on

2014-05-26

Participant Flow

Participant milestones

Participant milestones
Measure
Restrictive Group
Restrictive group: A group of patients who received ≤ 8ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid administered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Liberal Group
Liberal group: A group of patients who received \> 8 ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid admnistered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Overall Study
STARTED
8
8
Overall Study
COMPLETED
8
8
Overall Study
NOT COMPLETED
0
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Volume Restriction in Esophageal Carcinoma Surgery: Randomized Clinical Trial

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Restrictive Group
n=8 Participants
Restrictive group: A group of patients who received ≤ 8ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid administered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Liberal Group
n=8 Participants
Liberal group: A group of patients who received \> 8 ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid admnistered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Total
n=16 Participants
Total of all reporting groups
Age, Continuous
53.91 years
STANDARD_DEVIATION 8.31 • n=99 Participants
52.41 years
STANDARD_DEVIATION 13.41 • n=107 Participants
53.12 years
STANDARD_DEVIATION 1.81 • n=206 Participants
Sex: Female, Male
Female
2 Participants
n=99 Participants
4 Participants
n=107 Participants
6 Participants
n=206 Participants
Sex: Female, Male
Male
6 Participants
n=99 Participants
4 Participants
n=107 Participants
10 Participants
n=206 Participants
ASA score
2.61 units on a scale
STANDARD_DEVIATION 0.51 • n=99 Participants
2.75 units on a scale
STANDARD_DEVIATION 0.46 • n=107 Participants
2.71 units on a scale
STANDARD_DEVIATION 0.48 • n=206 Participants
Body weight
70.01 kg
STANDARD_DEVIATION 18.91 • n=99 Participants
66.31 kg
STANDARD_DEVIATION 12.61 • n=107 Participants
68.11 kg
STANDARD_DEVIATION 17.61 • n=206 Participants

PRIMARY outcome

Timeframe: 10 minutes, 6 hours

At the given time point, 10 minutes after beginning of the Lewis Tanner procedure and 6 hours after, arterial oxygen partial pressure (PaO2), inspired oxygen fraction (FiO2), and the PaO2/FiO2 ratio will be measured. The results of Pa02/FiO2 ratio will be compared between two groups for each time point separately.

Outcome measures

Outcome measures
Measure
Restrictive Group
n=8 Participants
A group of patients who received ≤ 8ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid administered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Liberal Group
n=8 Participants
A group of patients who received \> 8 ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid admnistered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Pulmonary Gas Exchange During and After Esophageal Carcinoma Surgery (PaO2/FiO2 Ratio)
10 minutes
345.01 mmHg
Standard Deviation 35.31
330.11 mmHg
Standard Deviation 34.71
Pulmonary Gas Exchange During and After Esophageal Carcinoma Surgery (PaO2/FiO2 Ratio)
6 hours
315.51 mmHg
Standard Deviation 32.91
307.11 mmHg
Standard Deviation 30.31

PRIMARY outcome

Timeframe: 10 minutes, 6 hours

At the given time points, 10 minutes after beginning of the Lewis Tanner procedure and 6 hours after, creatinine blood levels will be measured. The results will be compared between two groups for each time point separately.

Outcome measures

Outcome measures
Measure
Restrictive Group
n=8 Participants
A group of patients who received ≤ 8ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid administered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Liberal Group
n=8 Participants
A group of patients who received \> 8 ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid admnistered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Creatinine Values During and After Esophageal Carcinoma Surgery
10 minutes
91.91 μmol/L
Standard Deviation 12.67
90.88 μmol/L
Standard Deviation 14.99
Creatinine Values During and After Esophageal Carcinoma Surgery
6 hours
93.51 μmol/L
Standard Deviation 16.37
100.88 μmol/L
Standard Deviation 18.33

PRIMARY outcome

Timeframe: 10 minutes, 6 hours

At the given time points, ten minutes after beginning of the Lewis Tanner procedure and six hours after procedure, blood levels of the lactate will be measured and compared between two groups for each time point separately.

Outcome measures

Outcome measures
Measure
Restrictive Group
n=8 Participants
A group of patients who received ≤ 8ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid administered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Liberal Group
n=8 Participants
A group of patients who received \> 8 ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid admnistered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Lactate Values During and After Esophageal Carcinoma Surgery
10 minutes
3.93 mmol/L
Standard Deviation 1.33
3.26 mmol/L
Standard Deviation 1.25
Lactate Values During and After Esophageal Carcinoma Surgery
6 hours
2.69 mmol/L
Standard Deviation 0.91
2.40 mmol/L
Standard Deviation 1.08

PRIMARY outcome

Timeframe: 10 minutes, 6 hours

At the given time points, ten minutes after beginning of the Lewis Tanner procedure and six hours after procedure, blood levels of the lactate will be measured and compared inside the same group (liberal or restrictive).

Outcome measures

Outcome measures
Measure
Restrictive Group
n=8 Participants
A group of patients who received ≤ 8ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid administered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Liberal Group
n=8 Participants
A group of patients who received \> 8 ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid admnistered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Changes in Lactate Levels During Esophageal Carcinoma Surgery Using Restrictive or Liberal Fluid Management.
10 minutes
3.93 mmol/L
Standard Deviation 1.33
3.26 mmol/L
Standard Deviation 1.25
Changes in Lactate Levels During Esophageal Carcinoma Surgery Using Restrictive or Liberal Fluid Management.
6 hours
2.69 mmol/L
Standard Deviation 0.91
2.40 mmol/L
Standard Deviation 1.08

SECONDARY outcome

Timeframe: End of surgery.

Total time of Lewis-Tanner procedure will be measured and compared between two groups.

Outcome measures

Outcome measures
Measure
Restrictive Group
n=8 Participants
A group of patients who received ≤ 8ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid administered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Liberal Group
n=8 Participants
A group of patients who received \> 8 ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid admnistered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Duration of Surgery
275.61 minutes
Standard Deviation 91.21
324.41 minutes
Standard Deviation 116.61

SECONDARY outcome

Timeframe: End of surgery

Total volume of intraoperatively given fluid according to the protocol will be measured and compared between two groups.

Outcome measures

Outcome measures
Measure
Restrictive Group
n=8 Participants
A group of patients who received ≤ 8ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid administered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Liberal Group
n=8 Participants
A group of patients who received \> 8 ml/kg/h of intraoperative fluid during esophageal carcinoma surgery. The fluid admnistered: Plasma-Lyte 148 (pH 7.4; Viaflo, Baxter, US), 10% Aminoven (Fresenius Kabi AG, Bad Homburg, Germany) at 0.5 ml/kg/h, 5 ml/kg of colloid (6% Voluven 130/0.4, Fresenius Kabi AG, Bad Homburg, Germany), packed red blood cells.
Total Volume of Administered Intraoperative Fluid
2823.75 milliliters
Standard Deviation 965.8
3960.00 milliliters
Standard Deviation 755.9

Adverse Events

Restrictive Group

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Liberal Group

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Maja Karaman Ilić, MD PhD

KBC Zagreb

Phone: 00385 1 2385 122

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place