The Efficacy and Safety of Accufuser Omnibus® (Elastomeric Infusion Pump); Comparative Clinical Trial
NCT01976494 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 86
Last updated 2015-06-19
Summary
Acute post-operative pain causes not only discomfort for the patient, but delays recovery by increasing the morbidity of the circulatory system, respiratory system, and immune system, so pain control is one of the important objectives in peri-operative patient management. Patient controlled analgesia (PCA) is a piece of equipment for which the patient can personally control the administration of an analgesic. It is generally used in postoperative pain management because it is a method which can heighten patient satisfaction by reducing complications and obtaining the appropriate level of pain relief. Usually, it is designed to administer an analgesic at a steady speed, and the patient can administer additional medication by pressing a button when the pain is severe. Here, to prevent complications from excessive administration of an analgesic, repeated administration is not allowed within a certain time interval. The PCA equipment can be categorized as electronic and physical according to the force which operates the drug injection pump. Electronic equipment uses electrical energy to apply vermicular movement to the fluid tube to administer the analgesic. Physical equipment is disposable equipment designed to fill an elastomer reservoir bag expanding the material, and its elasticity returns to the original length used to administer the analgesic. The physical equipment is easy to carry and movement is comfortable because there is no need for additional electronic equipment or devices. There is also no need for special training to operate the equipment, and the action mechanism is simple so there is less opportunity for malfunction. The disposable physical equipment accounts for approximately 70% of the domestic market share and it is preferred over the electronic equipment. On the other hand, contrary to the electronic equipment, the physical PCA equipment has the disadvantage of not providing information regarding the history of the equipment's use. The early physical PCA equipment was very simple and only had the function of continually administering medication at a set speed. Hence, it was not sufficient to function as 'patient controlled' pain control equipment. Then, the function of an additional administration button was added so that the patient can personally decide whether to administer an additional amount of analgesic. At the same time, the physical PCA equipment has improved to prevent excessive administration by setting a lock-out time as a safety measure. The following development was Accufuser Selectuss®, where a function was added to select the administration speed from three options. In this way, the physical PCA equipment has continued to evolve in the direction of enhancing safety, convenience, and clinical effectiveness. The advantage of pain control using PCA equipment is that the patient can personally control additional the administration of an analgesic by pressing a button. In the case of existing or imported products, it is designed to administer a bolus by pressing the button, and the pressure presses the PVC bag filled with medication under the button to administer the bolus. Compared to the intravenous route, using an epidural as a PCA administration route has superior analgesic effect, so it can reduce the amount of opioid analgesic administered. On the other hand, the disadvantage is that it has to pass through a narrow and long epidural catheter to deliver the medication to the epidural space which has a relatively higher resistance. Woo Young Medical experimented with their own product Accufuser plus® (Woo Young Medical, Korea), and the results showed that the time taken to empty the bolus bag was approximately 40-80 seconds depending on the dosage. The pressure when a person presses the bolus button on the PCA equipment was repeatedly measured to obtain a mean value, and this pressure was constantly maintained by a machine to measure the time taken to empty the bolus bag. Clinically, it is not easy to continually press the button for 40-80 seconds, so it is difficult to exclude the possibility that the bolus was not administered properly. In addition, when excessive pressure is applied, there is the possibility that the bolus bag may burst. The domestically developed products and Accufuser Omnibus® (Woo Young Medical, Korea) was developed for the purpose of supplementing bolus failure which can occur when using epidural PCA. Within the bolus module, a second elastomeric balloon is installed behind the first bolus bag so the patient does not have to press the bolus button for a long time.
Therefore, this research focused on the effectiveness and safety of the domestic product Accufuser Omnibus® (Woo Young Medical, Korea) regarding whether the bolus is sufficiently delivered when it is administered through the epidural route, and compared the results through a comparative clinical trial with imported physical PCA equipment (Infusor SV®, Baxter, USA).
Conditions
- Upper Gastrointestinal Cancer
Interventions
- DEVICE
-
The domestic PCA equipment 'Accufuser Omnibus®'
* Subject patient selection: the purpose and method of this research will be explained to the patients who satisfy the exclusion criteria before surgery, and written consent regarding research participation will be obtained. * Use of PCA equipment by patients is determined by randomization. Regardless of the PCA equipment type, the basal rate and bolus dose are equally set to 2 mL/hr and 2 mL for the entire research period. * Epidural PCA regime: normal saline added to 0.75% ropivacaine 40 mL and fentanyl 15-20 mcg/kg for a total volume of 100 ml. * After pretreatment, the chest epidural catheter is mounted in the pretreatment room or operating room. The catheter tip is adjusted to be fixed between T6-7 or T7-8. * After mounting the catheter, a test dose of 1% lidocaine 3 ml and epinephrine 1:200.000 is injected. Ten minutes later, sensory loss and skin dermatome will be checked using an alcohol swab.
- DEVICE
-
Imported PCA equipment 'Infusor SV®, Baxter, USA'
* Subject patient selection: the purpose and method of this research will be explained to the patients who satisfy the exclusion criteria before surgery, and written consent regarding research participation will be obtained. * Use of PCA equipment by patients is determined by randomization. Regardless of the PCA equipment type, the basal rate and bolus dose are equally set to 2 mL/hr and 2 mL for the entire research period. * Epidural PCA regime: normal saline added to 0.75% ropivacaine 40 mL and fentanyl 15-20 mcg/kg for a total volume of 100 ml. * After pretreatment, the chest epidural catheter is mounted in the pretreatment room or operating room. The catheter tip is adjusted to be fixed between T6-7 or T7-8. * After mounting the catheter, a test dose of 1% lidocaine 3 ml and epinephrine 1:200.000 is injected. Ten minutes later, sensory loss and skin dermatome will be checked using an alcohol swab.
Sponsors & Collaborators
-
Small and Medium Business Administration
collaborator UNKNOWN -
Yonsei University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- SUPPORTIVE_CARE
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 20 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2013-10-31
- Primary Completion
- 2014-07-31
- Completion
- 2014-08-31
Countries
- South Korea
Study Locations
More Related Trials
-
Transurethral Ventral Wall of Urethra-preserving Enucleation of Prostate
NCT01073241 ·Status: UNKNOWN ·Phase: NA
-
Effect of Radical Prostatectomy on Involuntary Pelvic Floor Muscle Contraction
NCT03574298 ·Status: COMPLETED
-
Pain Comparison Whit Visual Analog Scale (EVA) Between Four Analgesic Methods During Trans Rectal Prostatic Biopsy
NCT03442075 ·Status: COMPLETED
-
The Effect of Combined General/Epidural Anesthesia Versus General Anesthesia on Diaphragmatic Function
NCT01547416 ·Status: COMPLETED ·Phase: PHASE4
-
Evaluation of Efficacy and Accuracy of Aquamantys Device in General Surgery
NCT01929902 ·Status: COMPLETED
-
Intraoperative Electrical Impedance Tomography in Obese Patients Undergoing Robotic Assisted Radical Prostatectomy.
NCT04757025 ·Status: UNKNOWN ·Phase: NA
-
Prevention of Urinary Incontinence After Prostatectomy
NCT00982098 ·Status: UNKNOWN ·Phase: NA
-
Intra-operative Neuromodulation of the Pelvic Plexus
NCT03425240 ·Status: UNKNOWN ·Phase: NA
-
Prostate Capsule Sparing Cystectomy and Nerve-sparing Radical Cystoprostatectomy in Men With Bladder Cancer
NCT01824329 ·Status: COMPLETED ·Phase: PHASE2
-
Mixture Nitrous Oxide - Oxygen 50-50% in Transrectal Prostate Biopsy Guided by Ultrasound
NCT02899182 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
A Study of a New Local Anesthesia Method for Transperineal Prostate Biopsy
NCT03500432 ·Status: COMPLETED ·Phase: NA
-
Role of Low-intensity Shock Wave Therapy in Penile Rehabilitation Post Nerve Sparing Radical Cysto-prostatectomy
NCT02422277 ·Status: UNKNOWN ·Phase: PHASE2
-
Application-based Perioperative Management of the Radical Cystectomy Patient
NCT02942121 ·Status: COMPLETED ·Phase: NA
-
The CUSA Clarity Soft Tissue Removal Study
NCT04298268 ·Status: COMPLETED
-
The Effect of TENS on Pain, Complications and Comfort in Patients Who Had Prostate Biopsy With Transrectal Ultrasound
NCT06414421 ·Status: COMPLETED ·Phase: NA
-
Prospective Trial to Evaluate Efficacy and Accuracy of a Portable Ultrasound Scanner for Non-Invasive Bladder Volume Measurement (BladderScan BVI3000) in Patients After Radical Cystectomy and Bladder Reconstruction
NCT00512174 ·Status: UNKNOWN ·Phase: NA
-
Robot-Assisted Radical Prostatectomy With or Without Vesicopexy in Patients With Prostate Cancer
NCT04981834 ·Status: SUSPENDED ·Phase: NA
-
The Use of Remote Monitoring to Improve Patient-Reported Outcomes and Readmission Rates Following Radical Cystectomy
NCT06397040 ·Status: COMPLETED ·Phase: NA
-
Lung US for PEEP Optimization in Robotic Radical Prostatectomy or Cystectomy Patients
NCT06307704 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Predictors of de Novo Urge Urinary Incontinence After Photoselective Vaporization of the Prostate
NCT02243085 ·Status: UNKNOWN
-
Electrical Stimulation in Men With Urinary Incontinence After Radical Prostatectomy
NCT05236140 ·Status: UNKNOWN ·Phase: NA
-
Brain and Pelvic Floor Muscle Activity of Patients Who Had or Are Undergoing Robot-Assisted Radical Prostatectomy
NCT04646434 ·Status: RECRUITING ·Phase: NA
-
Influence of Immune Nutrition Diet on 90-Day Outcomes in Patients Undergoing Radical Cystectomy
NCT03147586 ·Status: UNKNOWN ·Phase: PHASE4
-
The Relationship Between Bone Pelvis Measurements and Erectile Function in Patients Who Had Nerve-Sparing Robot-Assisted Radical Prostatectomy Operation
NCT06179316 ·Status: NOT_YET_RECRUITING
-
Dorsal Penile Block for Post-Robotic Prostatectomy Foley Discomfort
NCT01565512 ·Status: WITHDRAWN ·Phase: PHASE1/PHASE2