Background The standard care in patients with a painful osteoporotic vertebral compression fracture (VCF) is conservative therapy. Percutaneous vertebroplasty (PV), a minimally invasive technique, is a relatively new treatment option. Recent randomized controlled trials (RCT) provide conflicting results: two sham-controlled studies showed no benefit of PV while an unmasked but controlled RCT (VERTOS II) found effective pain relief at acceptable costs in patients with acute VCFs. A still ongoing masked RCT (VERTOS IV) focuses on acute VCFs defined as ≤ 6 weeks. VERTOS III focused on conservative treatment and found that half of patients still had disabling pain after 3 months or longer. These patients with sustained pain after 3 months may benefit from PV.
Objective To compare pain relief after PV with a sham intervention in selected patients with a chronic osteoporotic VCF ( three months or longer) using the same strict inclusion criteria as in VERTOS II an IV. Secondary outcome measures are back pain related disability and quality of life.
Methods The VERTOS V study is a prospective RCT with pain relief as primary endpoint. Inclusion criteria are a VCF of thoracic level 5 or lower with focal tenderness at fracture level, assessed by an internist on physical examination and a Visual Analogue Scale (VAS) score ≥ 5 for three months or longer, decreased bone density defined as T score ≤ -1 and age 50 years or older. 94 patients will be included, 47 in each arm. Crossovers are not allowed. Follow-up is at regular intervals during one year period with VAS score for pain as primary endpoint. Secondary endpoints are back pain related disability and quality of life measured with the Quality of Life Questionnaire of the European Foundation for Osteoporosis and physical function measured with the Roland Morris Disability questionnaire.
Conclusion Vertos V is a methodologically sound masked randomised sham controlled trial of vertebroplasty in patients with sustained pain 3 months or longer after a vertebral compression fracture.
Conditions
- Osteoporosis
- Vertebral Fracture
Interventions
- DEVICE
-
percutaneous vertebroplasty
Using fluoroscopic guidance, the practitioner infiltrates the skin and subcutaneous tissues overlying the pedicle of the target vertebra or vertebrae with 1% lidocaine and infiltrates the periosteum of the pedicles with 0.25% bupivacaine (marcaine. For the vertebroplasty procedure, 11-gauge or 13-gauge needles are passed into the central aspect of the target vertebra or vertebrae. Bone cement is prepared on the bench and injected under constant fluoroscopy into the vertebral body. Injection is stopped when the PMMA reaches the posterior aspect of the vertebral body or leaks into an extraosseous space, such as the intervertebral disk or an epidural or paravertebral vein.
- PROCEDURE
-
Sham procedure
Using fluoroscopic guidance, the practitioner infiltrates the skin and subcutaneous tissues overlying the pedicle of the target vertebra or vertebrae with 1% lidocaine and infiltrates the periosteum of the pedicles with 0.25% bupivacaine (marcaine). During the sham intervention, verbal and physical cues, such as pressure on the patient's back, are given, and the methacrylate monomer (PMMA) is opened to simulate the odor associated with mixing of cement, but the needle is not placed and cement is not injected.
Sponsors & Collaborators
-
Stryker Medical
collaborator INDUSTRY - collaborator INDUSTRY
-
Elisabeth-TweeSteden Ziekenhuis
lead OTHER
Principal Investigators
-
Dennis Carli, drs · Elisabeth Tweesteden Ziekenhuis/ SJG Weert
-
Paul Lohle, dr. · Elisabeth-TweeSteden Ziekenhuis
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 50 Years
- Max Age
- 95 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-05-31
- Primary Completion
- 2020-09-03
- Completion
- 2020-09-03
Countries
- Netherlands
Study Locations
More Related Trials
-
A Safety and Efficacy Study for Treatment of Painful Vertebral Compression Fractures Caused by Osteoporosis
NCT00290862 ·Status: UNKNOWN ·Phase: NA
-
Vertebroplasty Compared With a Sham-procedure for Painful Acute Osteoporotic Vertebral Fractures
NCT01537770 ·Status: COMPLETED ·Phase: NA
-
Comparison of Balloon Kyphoplasty and Vertebroplasty in Subacute Osteoporotic Vertebral Fractures
NCT00749086 ·Status: COMPLETED ·Phase: PHASE4
-
Clinical Evaluation of the Crosstrees Pod™ in the Treatment of Pathologic Fracture of the Vertebral Body (Levels T4 - L5) in Adult Patients
NCT00933036 ·Status: COMPLETED ·Phase: NA
-
The Purpose of This Study is to Evaluate Safety and Performance of the V-STRUT© Transpedicular Vertebral System
NCT03580434 ·Status: COMPLETED ·Phase: NA
-
Percutaneous Vertebral-disc Plasty for Thoracolumbar Very Severe Osteoporotic Vertebral Compression Fractures
NCT05519332 ·Status: RECRUITING ·Phase: NA
-
Quality of Life After Vertebroplasty Versus Conservative Treatment in Patients With Painful Osteoporotic Vertebral Fractures
NCT00994032 ·Status: COMPLETED ·Phase: NA
-
Vertos Mild - Post Market Patient Outcomes
NCT01076244 ·Status: COMPLETED ·Phase: NA
-
Vertebropexy - Randomized-controlled Trial
NCT06024785 ·Status: RECRUITING ·Phase: NA
-
A Multi-center Prospective Randomized Controlled Study on Clinical and Radiographic Analysis of ProDisc-C Vivo
NCT03367039 ·Status: UNKNOWN ·Phase: NA
-
OsteoStrux™ Collagen Ceramic Scaffold in Instrumented Lumbar Spine Fusion
NCT01873586 ·Status: COMPLETED ·Phase: NA
-
Clinical and Radiological Outcomes: Two-level Cervical ProDisc-C Vivo Versus Hybrid Construct.
NCT03367052 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Vertebroplasty Using Real-Time, Fluoroscopy-Controlled, Catheter-Assisted, Low-Viscosity Cement Injection
NCT00689923 ·Status: UNKNOWN
-
2-level Cervical Disc Replacement Comparing Prodisc C SK & Vivo to Mobi-C
NCT04012996 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Post-Market Study of The Tripod-Fix Vertebral Body Augmentation System in Osteoporotic Vertebral Compression Fractures
NCT06270173 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Percutaneous Vertebroplasty Versus Conservative Treatment of Pain
NCT00203554 ·Status: COMPLETED ·Phase: NA
-
Cost Effectiveness and Efficacy of Kyphoplasty and Vertebroplasty Trial
NCT00279877 ·Status: COMPLETED ·Phase: PHASE3
-
Intracept Minimally-invasive PROcedure for VErtebrogenic Back Pain
NCT06827262 ·Status: RECRUITING
-
Safety and Efficacy Study Comparing ProDisc-C to ACDF Surgery to Treat SCDD
NCT00291018 ·Status: COMPLETED ·Phase: NA
-
KAVIAR Study - Kyphoplasty And Vertebroplasty In the Augmentation and Restoration of Vertebral Body Compression Fractures
NCT00323609 ·Status: TERMINATED ·Phase: NA
-
To Evaluate Success of Cement Treatment of Spinal Compression Fractures
NCT00166374 ·Status: COMPLETED ·Phase: NA
-
Vertebral Augmentation Using VCFix Spinal System in Stand-alone Configuration
NCT07259811 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
An Assessment of P-15 Bone Putty in Anterior Cervical Fusion With Instrumentation
NCT00310440 ·Status: COMPLETED ·Phase: NA
-
Study of OP-1 Putty in Uninstrumented Posterolateral Fusions
NCT00678353 ·Status: COMPLETED
-
Medtronic SCORE Study - Study of Curette Use for Obtaining Restoration of Vertebral Body Anatomy in Balloon Kyphoplasty
NCT00810043 ·Status: COMPLETED ·Phase: PHASE4