Assessment of the AB HiFocusTM Mid Scala Electrode Movement Using Cone Beam Imaging Following Cochlea Implantation
NCT01940783 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 14
Last updated 2013-09-12
Summary
One of the contributing factors to the variability in outcomes amongst Cochlear Implant (CI) recipients was reported to be the placement of the electrode array in the scala tympani. It seems that the correct placement of the electrode initially into the scala tympani and subsequent avoidance of dislocation into the scala vestibuli as the insertion progresses, is a key factor in achieving good speech perception outcomes. Another important aspect related to the performance is the achievement of consistent electrical coverage with the electrode. Data reported for electrodes of different manufacturers give depths ranging from 240 - 600 degrees showing the considerable variation across subjects. The HiFocus mid scala electrode was developed to cover one and a quarter turn and with the pre-curved design to be less susceptible to variations in individual cochlea dimensions and insertion techniques. A further mechanical feature of the pre-curved design is the avoidance of forces against the cochlear lateral wall and associated lower susceptibility of the electrode for moving out of the cochlea following insertion. Recently, a cone beam CT (CBCT) technique is being explored in the field of ENT with the potential to overcome some of the issues associated with the conventional CT techniques such as scattering, radiation and low isometric resolution. Images with comparable details to those of e.g. micro CTs are possible with much lower radiation dose. Modern imaging software i.e. 3D Slicer (www.slicer.org) may be used for 3D reconstruction, post processing and Brainsfit for registration. Registration is the alignment of two scans in the same coordinate system. This enables the identification of differences between two images recorded at time x and y. Once accurately superimposed any difference between the two images may be identified with an accuracy of 0.2 mm. Using these methods, one can assess the stability and the position of the electrode in the cochlea.
Objective: The primary objectives of this study are to evaluate the feasibility of using cone beam CT technique in combination with (high resolution) MRI to identify electrode movements following cochlear implant surgery and identify the inter-scalar position of the HFms electrode. The secondary objective is to quantify the average insertion depth and variations of the HFms electrode
Conditions
- Cochlear Implantation
- Cone-Beam Computed Tomography
Interventions
- RADIATION
-
Cone Beam Computed Tomography (CBCT)
Two postoperative CBCT scans, the first one on the day after cochlear implantation and the second after 3 months.
- DEVICE
-
Magnetic Resonance Imaging (MRI)
One pre-operative (before cochlear implantation) MRI scan of the cochlea.
Sponsors & Collaborators
-
Advanced Bionics
collaborator INDUSTRY -
Maastricht University Medical Center
lead OTHER
Principal Investigators
-
Robert Stokroos, MD PhD · Maastricht University Medical Center
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-09-30
- Primary Completion
- 2014-09-30
- Completion
- 2014-09-30
Countries
- Netherlands
Study Locations
More Related Trials
-
Multi-center Study to Examine Changes to the Environment Surrounding the Electrodes in the Cochlea and to Capture the Most Challenging Listening Environments Experienced by Persons With a Cochlear Implant
NCT06173687 ·Status: COMPLETED ·Phase: NA
-
Role of Diagnostic Imaging in Cochlear Implant
NCT04711538 ·Status: UNKNOWN
-
Electric Pace-pitched Hearing Achieves Natural Tonotopy
NCT03892941 ·Status: UNKNOWN ·Phase: NA
-
Inventory of Radiological and Vestibular Function in Cochlear Implant Candidates
NCT04066270 ·Status: UNKNOWN
-
Investigating Electrical Categorical Loudness Scaling Using a Mobile Research App in Experienced Adult Cochlear Implant Participants
NCT07077070 ·Status: COMPLETED ·Phase: NA
-
Clinical Utility of Residual Hearing in the Cochlear Implant Ear
NCT04707885 ·Status: RECRUITING ·Phase: NA
-
Cone Beam CT Versus Multislice CT in the Postoperative Assessment of Cochlear Implantation
NCT02892552 ·Status: COMPLETED ·Phase: NA
-
Stream Segregation and Speech Recognition in Noise in Individuals With Cochlear Implants
NCT04854031 ·Status: COMPLETED
-
Objective Measures in Implantable Hearing Devices
NCT01780025 ·Status: COMPLETED
-
Interest of the Cone Beam Scanner of Temporal Bones in the Analysis of Conductive Hearing Loss
NCT06164184 ·Status: RECRUITING
-
Electrode Placement and Audiologic Outcomes With the Advanced Bionics HiFocus L23 Electrode
NCT03858647 ·Status: TERMINATED
-
Using Electrocochleography During Cochlear Implantation of the Neuro Zti.
NCT04651660 ·Status: WITHDRAWN ·Phase: NA
-
Evaluation of Remote Fitting in Adult and Pediatric Users of the HiResolution Bionic Ear System
NCT05034731 ·Status: COMPLETED
-
Longitudinal Outcomes in MED-EL Cochlear Implant Recipients Using a FLEX Electrode
NCT06343571 ·Status: COMPLETED
-
Clinical Trial to Compare Two Surgical Approaches to the Cochlea
NCT06453343 ·Status: RECRUITING ·Phase: NA
-
Cone Beam vs MDCT for Diagnosis and Pre-operative Evaluation of Otosclerosis
NCT05214053 ·Status: TERMINATED ·Phase: NA
-
Scalar Localization Cochlear Electrode Array Using 64 Slice CT
NCT00587262 ·Status: COMPLETED
-
Post-market Clinical Follow-up of a Magnetic Bone Conduction Implant (Cochlear Baha Attract System)
NCT02022085 ·Status: COMPLETED ·Phase: NA
-
Nucleus Hybrid L24 Extended Duration Post Approval Study
NCT02379273 ·Status: COMPLETED ·Phase: NA
-
Characterisation of Low Frequency Hearing and Vestibular Function in Patients Undergoing Cochlear Implantation
NCT06021132 ·Status: ACTIVE_NOT_RECRUITING
-
RBANS-H in Older Patients Before and After Cochlear Implantation: A Protocol for a Prospective Study
NCT02794350 ·Status: RECRUITING
-
Comparing the Performance of a Categorical Loudness Scaling Based Fitting With a Behavioural Fitting in Adults With a Nucleus Cochlear Implant 3 Months Post-activation
NCT05709223 ·Status: COMPLETED ·Phase: NA
-
Impact of Microphone Positioning on Auditory Performance in Cochlear Implant Users
NCT04677517 ·Status: WITHDRAWN ·Phase: NA
-
Status Telemetry for Cochlear Implantations
NCT06223724 ·Status: RECRUITING
-
Establish a Concordance Between the Mismatch Negativity Amplitude and a Score of Logatoms Discrimination
NCT03025386 ·Status: TERMINATED ·Phase: NA