Acute Effects of a Flutter Device in COPD
NCT01832961 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 15
Last updated 2020-02-27
Summary
Chronic obstructive pulmonary disease (COPD) is characterised by airflow limitation that is not fully reversible, and is usually progressive and associated with an abnormal inflammatory response of the lungs to noxious particles or gases, most commonly cigarette smoking. The disease affects not only the large central airways but also the small, more peripheral airways deeper into the lung, defined as less than 2 mm in diameter.
Besides medical treatment, physiotherapy plays a major role in treatment and various methods have been suggested to remove airway of secretions. The flutter is a simple and small device shaped like a pipe that creates a positive expiratory pressure (PEP) and high frequency oscillation when the expired air passes through it. These vibrations are thought to mobilise airway secretions facilitating their clearance and improving breathing.
Standard blowing tests, like spirometry, where patients blow forcedly into a machine, have previously been used to investigate the efficacy of flutter devices. However, spirometry assesses the damage of larger airways but not small airways, also known as the "silent zone" which, crucially, are specifically damaged in COPD.
In this study the investigators hypothesise that because the flutter helps clear the airways from the excessive thick mucus produced by COPD patients, these patients may find it easier to breathe and have lower resistance to moving air in and out of their lungs.
The main objective of this study is to compare the effect of a flutter or a sham device on small airways damage using impulse oscillometry (IOS), a non-invasive method that, contrary to other common blowing tests, measures small airway resistance during normal breathing.
In addition, because COPD is characterised by inflammation, the investigators would also like to measure a gas the patients blow out, nitric oxide (NO) the levels of which reflect airway inflammation. This will give to investigators an insight into the relationship between airway inflammation and small airway function.
Conditions
Interventions
- DEVICE
-
Flutter valve exercises
30 minutes of flutter exercises
- DEVICE
-
Flutter Sham exercises
30 minutes of flutter-sham exercises
- DEVICE
-
Flutter and bronchodilator exercises
Flutter + bronchodilator exercises with an interval of 3 to 5 days
Sponsors & Collaborators
-
Imperial College London
lead OTHER
Principal Investigators
-
Omar Usmani, MD · Imperial College London
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 21 Years
- Max Age
- 90 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-04-30
- Primary Completion
- 2013-12-31
- Completion
- 2013-12-31
Countries
- United Kingdom
Study Locations
More Related Trials
-
Implemental Flutter Mucus Clearance Devices on Geriatric Lung Function
NCT00881335 ·Status: COMPLETED ·Phase: NA
-
Daily Activities Are Sufficient to Induce Dynamic Pulmonary Hyperinflation and Dyspnea in Chronic Obstructive Pulmonary Disease Patients
NCT01475812 ·Status: COMPLETED
-
Effects of Inspiratory and Expiratory Pressure Training Methods in Patients With Chronic Obstructive Pulmonary Disease
NCT02326181 ·Status: UNKNOWN ·Phase: NA
-
Home-based Exercise Training for COPD Patients
NCT03461887 ·Status: COMPLETED ·Phase: NA
-
Fan Therapy in COPD Patients
NCT03137524 ·Status: COMPLETED ·Phase: NA
-
Clinical Outcomes in Patients Referred to Pulmonary Rehabilitation
NCT03591263 ·Status: UNKNOWN
-
Inspiratory Muscle Training and COPD
NCT04415788 ·Status: COMPLETED ·Phase: NA
-
Effects of Different Modes of Respiratory MuscleTraining on Respiratory Mechanics and NRD in Patient With Stable COPD.
NCT03500042 ·Status: COMPLETED ·Phase: NA
-
A Six Month Randomized Controlled Clinical Trial of Lung Flute in Patients With Chronic Obstructive Pulmonary Disease
NCT01186822 ·Status: COMPLETED ·Phase: NA
-
Airway Clearance for Prevention of Chronic Obstructive Pulmonary Disease (COPD) Exacerbation
NCT00181207 ·Status: COMPLETED ·Phase: PHASE4
-
Use of Endobronchial Valves in Non-Upper Lobe Heterogeneous Emphysema
NCT00825578 ·Status: COMPLETED ·Phase: PHASE3
-
Use of an Air Warming Mask for Exercise in Patients With COPD V1.0
NCT02266316 ·Status: UNKNOWN ·Phase: NA
-
High Frequency Chest Wall Oscillations Versus Lung Flute in Chronic Obstructive Pulmonary Disease Post(SARS-CoV-2)
NCT05591781 ·Status: UNKNOWN ·Phase: NA
-
Inspiratory Muscle Training for Patients With Chronic Obstructive Pulmonary Disorder
NCT02673242 ·Status: COMPLETED ·Phase: NA
-
Long-term Effects of Non-invasive Ventilation in Hypercapnic Chronic Obstructive Pulmonary Disease (COPD) Patients
NCT01592656 ·Status: TERMINATED ·Phase: PHASE2
-
Resistance Training to Prehabilitate Patients With Chronic Obstructive Pulmonary Disease
NCT02860728 ·Status: COMPLETED ·Phase: NA
-
Volume Parameters vs Flow Parameters in Assessment of Reversibility in Chronic Obstructive Pulmonary Disease
NCT03282526 ·Status: UNKNOWN ·Phase: NA
-
During-exercise Physiological Effects of Nasal High-flow in Patients With Chronic Obstructive Pulmonary Disease
NCT04014868 ·Status: COMPLETED ·Phase: NA
-
Aerosure and Six Minute Walk Distance in Severe COPD
NCT02007590 ·Status: COMPLETED ·Phase: NA
-
Inspiratory Muscle Training in Hypercapnic COPD
NCT00291460 ·Status: UNKNOWN ·Phase: PHASE4
-
Intra Versus Extra-thoracic Oscillations in Chronic Obstructive Pulmonary Disease
NCT03885128 ·Status: COMPLETED ·Phase: NA
-
Nocturnal Breathing and Sleep in Patients With Chronic Obstructive Pulmonary Disease Staying at Altitude
NCT01870830 ·Status: COMPLETED ·Phase: NA
-
Muscle Dysfunction in Patients With Chronic Obstructive Lung Disease (COPD): the Role of Sympathetic Activation
NCT01750489 ·Status: COMPLETED ·Phase: NA
-
Beta-Blocker in Chronic Obstructive Pulmonary Disease (COPD) Study
NCT00745043 ·Status: COMPLETED ·Phase: NA
-
Patients With Chronic Obstructive Pulmonary Disease at Altitude - Effect of Nocturnal Oxygen on Exercise Performance
NCT02143609 ·Status: COMPLETED ·Phase: PHASE4