Acute Effects of a Flutter Device in COPD

NCT01832961 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 15

Last updated 2020-02-27

Study results available
· View outcomes & findings →

Summary

Chronic obstructive pulmonary disease (COPD) is characterised by airflow limitation that is not fully reversible, and is usually progressive and associated with an abnormal inflammatory response of the lungs to noxious particles or gases, most commonly cigarette smoking. The disease affects not only the large central airways but also the small, more peripheral airways deeper into the lung, defined as less than 2 mm in diameter.

Besides medical treatment, physiotherapy plays a major role in treatment and various methods have been suggested to remove airway of secretions. The flutter is a simple and small device shaped like a pipe that creates a positive expiratory pressure (PEP) and high frequency oscillation when the expired air passes through it. These vibrations are thought to mobilise airway secretions facilitating their clearance and improving breathing.

Standard blowing tests, like spirometry, where patients blow forcedly into a machine, have previously been used to investigate the efficacy of flutter devices. However, spirometry assesses the damage of larger airways but not small airways, also known as the "silent zone" which, crucially, are specifically damaged in COPD.

In this study the investigators hypothesise that because the flutter helps clear the airways from the excessive thick mucus produced by COPD patients, these patients may find it easier to breathe and have lower resistance to moving air in and out of their lungs.

The main objective of this study is to compare the effect of a flutter or a sham device on small airways damage using impulse oscillometry (IOS), a non-invasive method that, contrary to other common blowing tests, measures small airway resistance during normal breathing.

In addition, because COPD is characterised by inflammation, the investigators would also like to measure a gas the patients blow out, nitric oxide (NO) the levels of which reflect airway inflammation. This will give to investigators an insight into the relationship between airway inflammation and small airway function.

Conditions

Interventions

DEVICE

Flutter valve exercises

30 minutes of flutter exercises

DEVICE

Flutter Sham exercises

30 minutes of flutter-sham exercises

DEVICE

Flutter and bronchodilator exercises

Flutter + bronchodilator exercises with an interval of 3 to 5 days

Sponsors & Collaborators

  • Imperial College London

    lead OTHER

Principal Investigators

  • Omar Usmani, MD · Imperial College London

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
CROSSOVER

Eligibility

Min Age
21 Years
Max Age
90 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2013-04-30
Primary Completion
2013-12-31
Completion
2013-12-31

Countries

  • United Kingdom

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT01832961 on ClinicalTrials.gov