Comparison of Three Surgical Techniques to Achieve Patella Symmetry During Resection
NCT01822574 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 90
Last updated 2016-03-02
Summary
This research was performed to determine which of the three techniques used by knee surgeons at the Mayo Clinic was the most accurate at the surgical removal (resection) of the knee-cap (patella) in a symmetric fashion during total knee replacement (arthroplasty). Although all three techniques are known to be effective, the three techniques had never been compared to one another to determine if one was more effective than the others at resecting the patella.
Conditions
- Arthroplasty, Replacement, Knee
- Injuries, Knee
Interventions
- PROCEDURE
-
Cutting Guide Technique
The guide is clamped onto the patella and tightened so that it remains stable. The guide has a slot that allows insertion of a standard sagittal saw blade, and this slot guides the blade as it is advanced across the patella. The thickness is then measured in the center of the patella to ensure that the resection goal is achieved. Additional resection may be performed as needed.
- PROCEDURE
-
Haptic Feedback Technique
It consists of a free hand cut (no guide used) with a standard sagittal saw that is oriented based on osteo-cartilaginous landmarks and haptic palpation of the patella by the surgeon. The resection thickness/obliquity can be altered based on haptic feedback (use of the sense of touch) of the patella. The thickness is then measured in the center of the patella to ensure that the resection goal is achieved. Additional resection may be performed as needed.
- PROCEDURE
-
Four Quadrant Technique
Resection is performed in a free handed fashion, but after resection, the thickness of the patella is measured separately in all four quadrants (superolateral, superomedial, inferomedial, and inferolateral). Additional resection is performed as needed based on the quadrant measurements and the measurements are repeated after each resection until satisfactory resection thickness and symmetry are obtained.
Sponsors & Collaborators
- lead OTHER
Principal Investigators
-
Robert Trousdale, MD · Mayo Clinic
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 99 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-03-31
- Primary Completion
- 2015-12-31
- Completion
- 2015-12-31
Countries
- United States
Study Locations
More Related Trials
-
Minimally Invasive Surgical Approaches In Total Knee Arthroplasty
NCT01461356 ·Status: COMPLETED ·Phase: NA
-
The Correlation Between Femoral Component Implanting Flexion Angle and Posterior Condyle Offset in Cruciate Retaining Total Knee Arthroplasty
NCT05477745 ·Status: UNKNOWN
-
The Impact of Tibial Tubercle-trochlear Groove Distance and Patellar Height on the Outcome of Isolated Medial Patellofemoral Ligament Reconstruction
NCT03076008 ·Status: ACTIVE_NOT_RECRUITING
-
Correlation Between Deficits in Knee ROM Recovery and Difficulty in Dorsiflexing the Tibio-tarsal Joint in Patients Undergoing Total Knee Replacement Surgery.
NCT07016243 ·Status: RECRUITING
-
Midvastus Versus Medial Parapatellar Approach for Minimally Invasive Total Knee Arthroplasty
NCT01132378 ·Status: COMPLETED ·Phase: NA
-
The Recovery Time of Quadriceps Strength After Total Knee Arthroplasty (TKA): The Effect of Quadriceps Incision Length
NCT01450904 ·Status: COMPLETED ·Phase: NA
-
Kinematic Alignment in Total Knee Arthroplasty - a Double-blind Randomised Controlled Trial Between Robotic and Caliper-based Techniques
NCT06709703 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Accuracy of MRI-based Patients Matched Instruments vs Jig-based Instruments in Total Knee Arthroplasty (TKA)
NCT01449474 ·Status: COMPLETED ·Phase: NA
-
Comparison of Quadriceps-sparing Minimally Invasive and Medial Parapatellar Total Knee Arthroplasty
NCT01160835 ·Status: COMPLETED ·Phase: PHASE4
-
Comparison of Femoral Tunnel and Clinical Outcome Using Two Anterior Cruciate Ligament Reconstruction Techniques
NCT02754674 ·Status: COMPLETED ·Phase: NA
-
Partial Synovectomy in Articular Side of Quadriceps Tendon Verified to Reduce Crepitus in Retrospective Study
NCT06129214 ·Status: RECRUITING ·Phase: NA
-
Navigated Total Knee Arthroplasty, the Correlation to CT Scans and Clinical Results
NCT02071745 ·Status: COMPLETED
-
Comparison of Anatomically Aligned and Conventional Total Knee Arthroplasty in the Same Patients
NCT04181216 ·Status: UNKNOWN ·Phase: NA
-
A Comparative Study of Knee Systems
NCT01331278 ·Status: COMPLETED ·Phase: PHASE4
-
Anatomic Reconstruction of the Patellofemoral Joint
NCT01375231 ·Status: COMPLETED ·Phase: PHASE4
-
Total Knee Arthroplasty Biomechanics
NCT03671954 ·Status: COMPLETED ·Phase: NA
-
Reconstruction of the Medial Patellofemoral Ligament - A Randomised Controlled Trial Comparing Two Surgery Technics
NCT02180685 ·Status: COMPLETED ·Phase: NA
-
Mechanical Alignment Versus Kinematic Alignment Total Knee Arthroplasty
NCT06486714 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical and Radiological Results of Long Term Tibial and Femoral Osteotomy in Knee Ostheoarthritis With Concomitant Lower Limb Malalignement
NCT06462625 ·Status: RECRUITING
-
Study of Surgical Technique With Use of Single-radius Prosthesis in Total Knee Replacement
NCT01505452 ·Status: COMPLETED
-
Validation of a New Technique for the Evaluation of the Patello-femoral Joint Kinematics
NCT03448198 ·Status: COMPLETED ·Phase: NA
-
Comparison of Radiological, Clinical, Functional Outcomes Between Anatomically Aligned Total Knee Arthroplasty and Conventional Total Knee Arthroplasty
NCT04183985 ·Status: UNKNOWN ·Phase: NA
-
Functional Outcome in Two Types of Total Knee Replacement Surgery for People With Osteoarthritis
NCT01576445 ·Status: COMPLETED ·Phase: PHASE2
-
Bicruciate-retaining (2C) Total Knee Arthroplasty (TKA) Versus Posterior-stabilized (PS) Total Knee Arthroplasty (TKA)
NCT05469776 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Shoe Lifts for Leg Length Inequality in Adults With Knee or Hip Symptoms
NCT01894100 ·Status: COMPLETED ·Phase: NA