CT Window Setting to Select Double-lumen Tube Size
NCT01818102 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 228
Last updated 2015-05-22
Summary
The purpose of this study is to investigate the appropriate window setting of chest computed tomography to select a correct size of double-lumen endobronchial tube.
Conditions
- Bronchial Cuff Volume at Air-tight Seal
- Intracuff Cuff Pressure at Air-tighe Seal
Interventions
- DEVICE
-
Width 1000 HU/Level -450 HU
Double-lumen tube size is selected according to the internal diameter of the left mainstem bronchus measured in the chest computed tomography with width 1000 HU and level -450 HU.
- DEVICE
-
Width 400 HU/Level 25 HU
Double-lumen tube size is selected according to the internal diameter of the left mainstem bronchus measured in the chest computed tomography with width 400 HU and level 25 HU.
Sponsors & Collaborators
-
Seoul National University Hospital
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- QUADRUPLE
- Model
- PARALLEL
Eligibility
- Min Age
- 20 Years
- Max Age
- 85 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-02-28
- Primary Completion
- 2014-02-28
- Completion
- 2014-02-28
Countries
- South Korea
Study Locations
More Related Trials
-
Volume CT of the Wrist and Carpus After Trauma
NCT01857570 ·Status: COMPLETED
-
Koning Breast CT for Breast Imaging in China
NCT01792999 ·Status: COMPLETED ·Phase: PHASE3
-
Usefulness of Coronary Computed Tomography Angiography for Therapeutic Decision- Making; Revascularization
NCT02099019 ·Status: UNKNOWN
-
Dose Reduction in Thoracic CT
NCT00188461 ·Status: COMPLETED ·Phase: PHASE1
-
Applications of Dual-Energy Computed Tomography
NCT01801514 ·Status: COMPLETED ·Phase: NA
-
Role of Pleural Fluid Attenuation Value on CT as a Diagnostic Tool in Traumatic Hemothorax
NCT04098185 ·Status: UNKNOWN
-
Improved Chest CT Diagnostic and Contrast Medium Administration
NCT05645796 ·Status: COMPLETED ·Phase: NA
-
Low-dose Whole Body Computed Tomography Scanning
NCT03425032 ·Status: COMPLETED
-
Computed Tomography Evaluation of Urinary Stones Densities Compared to in Vitro Analysis of Its Chemical Composition
NCT04110574 ·Status: UNKNOWN
-
Benefit of Tin Filter in Regards to Image Quality and Radiation Dose in CT Scan Study of Pulmonary Parenchyma
NCT04119141 ·Status: UNKNOWN ·Phase: NA
-
Usefulness of 64 Slice Multi-Detector Computed Tomography as a First Diagnostic Approach in Acute Chest Pain Patients
NCT00431886 ·Status: COMPLETED ·Phase: NA
-
Imaging Techniques in CT: Technical Development
NCT02242448 ·Status: TERMINATED
-
Vascular Abnormalities Detected With Chest CT in COVID-19
NCT04824313 ·Status: UNKNOWN
-
Estimating Patient Size From a Single Radiograph
NCT03341546 ·Status: COMPLETED
-
On Dose Efficiency of Modern CT-scanners in Chest Scans
NCT04996693 ·Status: COMPLETED ·Phase: NA
-
Chest CT-scan for the Diagnosis of Community-acquired Pneumonia
NCT01574066 ·Status: COMPLETED ·Phase: NA
-
Computed Tomography for COVID-19 Diagnosis
NCT04355507 ·Status: COMPLETED
-
CT Data Collection Study
NCT03589664 ·Status: COMPLETED
-
The Place of Imaging and Microbiology in the Diagnosis of Pneumonia in the Elderly
NCT02467192 ·Status: COMPLETED ·Phase: NA
-
Comparison of Contrast Agent Administration Protocols
NCT04300972 ·Status: COMPLETED ·Phase: NA
-
Comparison of Chest CT Findings Related to COVID-19 With RSNA and BSTI Guidelines
NCT04754633 ·Status: COMPLETED
-
Evaluating Validity of Clinical Criteria for Requesting Chest X-Rays in Trauma Patients
NCT01134744 ·Status: COMPLETED
-
Comparison of CXR and MnDCT
NCT00188435 ·Status: COMPLETED ·Phase: PHASE1
-
Radiation Dose Audit Reports to Reduce Radiation Exposure From CT Exams
NCT01405066 ·Status: COMPLETED ·Phase: NA
-
Ultra-low Dose Chest Computed Tomography: a Rule-out Tool for Community-acquired Pneumonia
NCT04541160 ·Status: COMPLETED