Right to Left Cardiac Shunt Detection
NCT01773252 · Status: TERMINATED · Phase: PHASE3 · Type: INTERVENTIONAL · Enrollment: 141
Last updated 2015-11-13
Summary
The purpose of this study is to evaluate the sensitivity and specificity of the Cardiox Flow Detection System (FDS) in identifying an intracardiac right-to-left shunt (RLS) compared to the results of transesophageal echocardiography (TEE).
RLS intracardiac shunts are associated with a number of clinically important syndromes including paradoxical thromboembolism (causing stroke or other systemic infarct), migraine headaches (particularly with aura), desaturation with obstructive sleep apnea, and decompression illness. From a research perspective, the detection of shunts in subjects with these types of syndromes is critical in helping to define the role of RLS in these disease processes. From a clinical perspective, shunt detection will be increasingly important in an era where interventional procedures for repairing cardiac defects are available for subjects determined to be at risk.
The currently accepted reference standard for detection of an intra-cardiac patent foramen ovale/atrial septal defect (PFO/ASD) RLS is a transesophageal echocardiography (TEE), a procedure that is invasive, uncomfortable, and requires conscious sedation.
Alternative options include transthoracic echocardiography (TTE) with injection of agitated saline (with and without Valsalva strain), a procedure that is far less sensitive than TEE due to the echocardiography imaging limitations seen in many adults.
Finally, transcranial Doppler (TCD) with injection of agitated saline (with and without Valsalva strain) is a newer entrant into this arena that does not require sedation or any invasive instrumentation.
The Cardiox Model 100 FDS utilizes an optical sensor positioned on the surface of the subject's skin at the scaphoid fossa of the ear. Next, a predetermined dose of an indicator dye, indocyanine green (ICG), is injected at a predetermined rate into a peripheral antecubital vein of the subject while the subject performs a breathing maneuver called a Valsalva maneuver. The exhalation by the subject into a mouthpiece connected to a pressure transducer via a flexible tubing extension, or its equivalent (ie, performing the Valsalva maneuver), is an essential step for all existing RLS detection methods. The Valsalva maneuver by the subject creates a pressure differential between the right and left sides of the heart. This Valsalva maneuver results in blood flow from the right side of the heart to the left side of the heart through an ASD, and/or causes a PFO, if present, to open, also allowing blood to flow directly from the right side to the left side of the heart without passing through the lungs (pulmonary vasculature) for oxygenation.
The Earpads, including their fluorescence sensor arrays (FSA), are used to measure the relative concentration (ie, fluorescence signal level) of ICG dye in the bloodstream as a function of time. If a premature inflection or peak occurs in the ICG dye concentration level at a time point prior to the rise and fall of the concentration associated with the main bolus of indicator, then a RLS is present in the heart. The amplitude of this premature ICG dye-dilution curve (referred to as "RLS-indicator dilution curve") is used to subsequently quantify the magnitude of the right-to-left shunt by ratiometrically comparing the amplitude of this RLS indicator dilution curve to the amplitude of the main indicator dilution curve associated with that portion of the injected ICG dye that follows the normal pathway from the right side of the heart, through the lungs, and into the left side of the heart (referred to as "normal indicator dilution curve").
Conditions
- Right to Left Shunt
- Patent Foramen Ovale
- Atrial Septal Defect
Interventions
- DEVICE
-
Flow Detection System
Sponsors & Collaborators
-
Cardiox Corporation
lead INDUSTRY
Principal Investigators
-
Michael W Jopling, MD · Cardiox Corporation
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-11-30
- Primary Completion
- 2015-10-31
- Completion
- 2015-11-30
Countries
- United States
Study Locations
More Related Trials
-
Role of Echocardiography in the Assessment of Right Ventricular Function in the Pediatric Population With Valvular Pulmonary Stenosis.
NCT04960085 ·Status: UNKNOWN
-
Development of an Algorithm to Detect Pulmonary Hypertension Using an Electronic Stethoscope
NCT05873387 ·Status: RECRUITING
-
Evaluation of Blood Flow Patterns in Lung Blood Vessels Using Ultrasound Technique in Patients With Congestive Heart Failure
NCT01744210 ·Status: WITHDRAWN
-
ADOPT: Improving Diagnosis of Pulmonary Hypertension With AI and Echo
NCT06145880 ·Status: WITHDRAWN
-
Assessment of Right Ventricular 2d-strain in Acute Respiratory Distress Syndrome
NCT02638844 ·Status: COMPLETED
-
HeartGuide: Preliminary Study
NCT05490303 ·Status: UNKNOWN ·Phase: NA
-
Hand Injected Ventriculography vs. Power Injected Left Ventriculography
NCT01310517 ·Status: TERMINATED
-
Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography
NCT00774657 ·Status: WITHDRAWN
-
Cardiac Function Under Stress for Early Detection of the Right Ventricular Insufficiency After Repair of Tetralogy of Fallot
NCT00564993 ·Status: TERMINATED ·Phase: PHASE3
-
Interchangeability of Right Ventricle Longitudinal Shortening in Echocardiography
NCT05404737 ·Status: COMPLETED ·Phase: NA
-
Effects of Changes in Fluid Status on Right Ventricular Volumes and Function
NCT02967315 ·Status: COMPLETED ·Phase: NA
-
Fetal Electrocardiogram Extraction-Pilot Study
NCT01681498 ·Status: TERMINATED
-
Cardiac Remodeling and Prognosis in Secondar Tricuspid Regurgitation
NCT03159923 ·Status: COMPLETED
-
Occluder Size Determination in Transcatheter ASD II Closure Based on 3D TEE Assessment
NCT02601768 ·Status: UNKNOWN
-
Enhanced Diagnosis of Ventricular Activation Pattern Using Intracardiac Electrograms
NCT02057588 ·Status: COMPLETED ·Phase: NA
-
Impact of High Mechanical Index Ultrasound Impulses on Left Ventricular Stroke Volume With Intravenous Microbubbles
NCT05700032 ·Status: WITHDRAWN ·Phase: NA
-
Assessing Myocardial Blood Flow and Blood Flow Reserve by Transoesophageal Echocardiography (TEE)
NCT00286559 ·Status: WITHDRAWN ·Phase: PHASE1/PHASE2
-
The Value of Three Dimensional Echocardiography in Congenital Cardiac Surgery
NCT02408848 ·Status: TERMINATED
-
Comparability of Hemodynamic Parameters Measured by Non-invasive Echocardiography and by Right Heart Catheterization
NCT03231774 ·Status: COMPLETED
-
Correlation Between an Impedance Cardiography Test for Decompensation and the Development of Left Ventricular Replacement Fibrosis
NCT07230964 ·Status: RECRUITING ·Phase: NA
-
A Study to Evaluate a Computerized Stethoscope Called ©Voqx to Diagnose Heart Disease
NCT04960280 ·Status: COMPLETED ·Phase: NA
-
Cardiac Hemodynamics During Left Ventricular Assist
NCT06115096 ·Status: RECRUITING
-
Cardiac Allograft Vasculopathy and Dobutamine Stress Echocardiography / Brain Natriuretic Peptide Coupling
NCT00384540 ·Status: COMPLETED ·Phase: NA
-
Use of POC Pocket Ultrasound in the Estimation of Left and Right Atrial Pressures
NCT03897647 ·Status: WITHDRAWN ·Phase: NA
-
Non-invasive Evaluation of Heart Transplant Rejection- Pilot Study
NCT00572286 ·Status: WITHDRAWN