Anterior Capsule Polishing Effect on Effective Lens Position

NCT01598428 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20

Last updated 2015-01-26

Study results available
· View outcomes & findings →

Summary

* The purpose of this study is to evaluate effects of anterior capsule polishing on effective lens position (ELP) and actual axial movement of the intraocular lens (IOL) by measuring anterior chamber depth (ACD)
* patients with bilateral age-related cataract undergo bilateral uneventful cataract surgeries with in-the- bag implantation of a single-piece hydrophobic acrylic foldable IOL (SN60WF). The anterior capsule was extensively polished using Whitman Shepherd Double-Ended Capsule Polisher in one eye randomly, and the other not. The ACD was measured 1day, 1 week, 1month, 3 months and 6 months with anterior segment Optical Coherence Tomograph (AS-OCT) postoperatively. The actual axial movement of IOL was defined as the root mean square (RMS) of the change in ELP at each visit.

Conditions

  • Cataract

Interventions

PROCEDURE

anterior capsule polishing

polish the anterior capsule and the equator of capsule extensively with a Whitman Shepherd Double-Ended Capsule Polisher

Sponsors & Collaborators

  • Shandong University

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
DOUBLE
Model
SINGLE_GROUP

Eligibility

Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2013-01-31
Primary Completion
2014-01-31
Completion
2014-01-31

Countries

  • China

Study Locations