Efficacy of Aquamantys for Reducing Transfusions With Anterior Supine Intermuscular Approach Total Hip Arthroplasty

NCT01583465 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 200

Last updated 2012-04-24

No results posted yet for this study

Summary

The purpose of this study is to establish whether or not there is a clinical advantage to the use of Aquamantys® System from Medtronic Advanced Energy (formerly Salient Surgical Technologies) in patients undergoing primary total hip arthroplasty via the anterior supine intermuscular surgical approach in terms of blood loss, transfusion and wound healing. Wound healing will be assessed by a blinded observer and based upon a simple and subjective criteria: a) as expected, b) better than expected or c) worse than expected. The blinded observer is experienced in the care of the surgical patient and wound evaluation.

Conditions

  • Osteoarthritis, Hip
  • Joint Deformities, Acquired
  • Hip Dislocation, Congenital
  • Osteonecrosis
  • Arthritis, Rheumatoid

Interventions

DEVICE

Aquamantys

Primary THA via the ASI approach will be performed using the Aquamantys Malleable Bipolar Sealer. The Aquamantys is a bipolar device that combines radio-frequency energy and saline to gently reach targeted tissue and provide a biomechanical seal. The saline acts as a conduit to allow the energy to penetrate the tissue from 1 to 2 mm where the collagen is transformed thus providing the seal. The saline also helps cool the tissue which allows for gentle handling of tissue, eliminating the black char that is a port for infection. The surgeon uses the Aquamantys to assist in tissue dissection, cauterize vessels, and to pre-treat fat pad in front of capsule prior to excision, to treat the entire anterior hip capsule prior to excision, treat oozing bone surfaces not covered by an implant.

DEVICE

standard electrocautery (Bovie)

Primary total hip arthroplasty via an anterior supine intermuscular approach will be performed with the assistance of standard electrocautery. The electrocautery is used in tissue dissection and to cauterize bleeding vessels.

Sponsors & Collaborators

  • Medtronic

    collaborator INDUSTRY
  • Mount Carmel Health System

    collaborator OTHER
  • Joint Implant Surgeons, Inc.

    lead OTHER

Principal Investigators

  • Keith R Berend, MD · Joint Implant Surgeons, Inc.

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Model
PARALLEL

Eligibility

Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2009-10-31
Primary Completion
2011-09-30
Completion
2011-09-30

Countries

  • United States

Study Locations

More Related Trials

Entities

Companies

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.