Trial Outcomes & Findings for Comparison of Kinematics for Subjects Implanted With a PFC Sigma Rotating Platform or Fixed Bearing TC3 Prosthesis (NCT NCT01290640)

NCT ID: NCT01290640

Last Updated: 2019-10-21

Results Overview

The values that were reported indicate the motion of the contact point from the start of the activity to the end of the activity. If the point translated forward (anteriorly) atop the tibial tray, the number was reported as positive. If the point traveled backwards (posteriorly) atop the tibial tray, the number was reported as negative.

Recruitment status

COMPLETED

Target enrollment

22 participants

Primary outcome timeframe

March 2013

Results posted on

2019-10-21

Participant Flow

09/2011-12/2012, hospital

Participant milestones

Participant milestones
Measure
Subjects Implanted With a DePuy Fixed-bearing Total Condylar I
Subjects implanted with a DePuy fixed-bearing Total Condylar III (TC3) TKA
Subjects Implanted With a DePuy PFC Rotating Platform TC3 TKA
Overall Study
STARTED
12
10
Overall Study
COMPLETED
12
10
Overall Study
NOT COMPLETED
0
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Comparison of Kinematics for Subjects Implanted With a PFC Sigma Rotating Platform or Fixed Bearing TC3 Prosthesis

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
PFC RP TC3 TKA
n=10 Participants
Subjects Implanted With a DePuy Fixed-bearing Total Condylar I
n=12 Participants
Total
n=22 Participants
Total of all reporting groups
Sex: Female, Male
Female
4 Participants
n=99 Participants
9 Participants
n=107 Participants
13 Participants
n=206 Participants
Sex: Female, Male
Male
6 Participants
n=99 Participants
3 Participants
n=107 Participants
9 Participants
n=206 Participants
Region of Enrollment
United States
10 participants
n=99 Participants
12 participants
n=107 Participants
22 participants
n=206 Participants
Age, Categorical
<=18 years
0 Participants
n=99 Participants
0 Participants
n=107 Participants
0 Participants
n=206 Participants
Age, Categorical
Between 18 and 65 years
0 Participants
n=99 Participants
0 Participants
n=107 Participants
0 Participants
n=206 Participants
Age, Categorical
>=65 years
10 Participants
n=99 Participants
12 Participants
n=107 Participants
22 Participants
n=206 Participants
Age, Continuous
70.7 years
STANDARD_DEVIATION 9.8 • n=99 Participants
74.06 years
STANDARD_DEVIATION 10.1 • n=107 Participants
72.5 years
STANDARD_DEVIATION 10.10 • n=206 Participants

PRIMARY outcome

Timeframe: March 2013

Population: Per protocol.

The values that were reported indicate the motion of the contact point from the start of the activity to the end of the activity. If the point translated forward (anteriorly) atop the tibial tray, the number was reported as positive. If the point traveled backwards (posteriorly) atop the tibial tray, the number was reported as negative.

Outcome measures

Outcome measures
Measure
Subjects With DePuy PFC Rotating Platform TC3 TKA
n=10 Implants
Subjects With DePuy PFC Fixed Bearing TC3 TKA
n=12 Implants
In Vivo Linear Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.
Lateral Anterior Posterior Deep Knee Bend
-3.51 mm
Standard Deviation 4.73
-2.52 mm
Standard Deviation 1.92
In Vivo Linear Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.
Medial Anterior Posterior Deep Knee Bend
-1.68 mm
Standard Deviation 2.15
-1.40 mm
Standard Deviation 1.43
In Vivo Linear Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.
Lateral Anterior Posterior Chair Rise
-10.31 mm
Standard Deviation 3.23
2.89 mm
Standard Deviation 3.64
In Vivo Linear Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.
Medial Anterior Posterior Chair Rise
-0.76 mm
Standard Deviation 3.95
1.02 mm
Standard Deviation 2.95
In Vivo Linear Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.
Lateral Anterior Posterior Gait
-0.88 mm
Standard Deviation 2.02
-1.3 mm
Standard Deviation 1.8
In Vivo Linear Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.
Medial Anterior Posterior Gait
.70 mm
Standard Deviation 2.51
-1.2 mm
Standard Deviation 1.5
In Vivo Linear Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.
Lateral Anterior Posterior Stair Descent
-8.18 mm
Standard Deviation 2.08
-1.92 mm
Standard Deviation 2.46
In Vivo Linear Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.
Medial Anterior Posterior Stair Descent
-1.96 mm
Standard Deviation 3.22
-1.71 mm
Standard Deviation 1.80

PRIMARY outcome

Timeframe: March 2013

Angular kinematics for fixed bearing and rotating platform TKA system - Axial Rotation The values that were reported indicate the rotation of the femur atop the tibial tray from the start of the activity to the end of the activity. If the femur rotated externally (posterior rollback of the lateral condyle, generally pivoted about the medial condyle), the number was reported as positive. If the femur rotated internally (anterior slide of the lateral condyle, generally pivoted about the medial condyle), the number was reported as negative.

Outcome measures

Outcome measures
Measure
Subjects With DePuy PFC Rotating Platform TC3 TKA
n=10 Implants
Subjects With DePuy PFC Fixed Bearing TC3 TKA
n=12 Implants
In Vivo Angular Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.
Axial Rotation Deep Knee Bend
8.35 degrees
Standard Deviation 8.94
1.99 degrees
Standard Deviation 4.00
In Vivo Angular Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.
Axial Rotation Chair Rise
12.22 degrees
Standard Deviation 8.29
-2.42 degrees
Standard Deviation 5.03
In Vivo Angular Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.
Axial Rotation Gait
6.66 degrees
Standard Deviation 6.37
.13 degrees
Standard Deviation 2.18
In Vivo Angular Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.
Axial Rotation Stair Descent
8.16 degrees
Standard Deviation 5.56
.24 degrees
Standard Deviation 4.17

Adverse Events

Subjects Implanted With a DePuy PFC Rotating Platform TC3 TKA

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Subjects Implanted With a DePuy Fixed-bearing Total Condylar I

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Dr. Richard Komistek, Professor

The University of Tennessee

Phone: 865-974-4159

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place