A Randomized Controlled Trial of the Uresta Continence Pessary
NCT01284244 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 36
Last updated 2017-03-31
Summary
Stress urinary incontinence (SUI) is defined as the involuntary loss of urine with an increase in abdominal pressure, caused either by a loss of support under the bladder neck, or intrinsic urethral sphincter deficiency. It is a common problem in women that can significantly impact quality of life, with up to 30% developing SUI at some point in their lifetime.
The most commonly utilized treatments for SUI include either pelvic floor (Kegel) exercises, or surgery. Many women find Kegel exercises unsatisfactory, but are reluctant to undergo a surgical procedure. Also, women who are poor candidates for surgery have limited options if Kegel exercises are unsuccessful. Over the years, there have been numerous attempts to develop effective non-surgical alternatives for treating SUI, but the results have been variable and the available data on efficacy limited.
A new intravaginal incontinence pessary (Uresta) has been developed for treating stress incontinence, and is currently available in Canada via a medical distributor. The self-positioning device is initially fitted by a healthcare provider, but then can subsequently placed by the patient as needed. Uresta is designed to be easily inserted into the vagina and spontaneously fall into position, providing support beneath the urethra. A single, uncontrolled study of 21 women showed that Uresta significantly reduces urinary incontinence measures, with no reported complications. Using questionnaires, a 47% reduction in self-reported SUI symptoms was demonstrated. Pad weight following a pad test, an objective assessment of urine loss, showed a 50% reduction in leakage.
This trial is intended to be a short-term assessment of the efficacy of the Uresta device, using a placebo arm in order to remove any of the possible sources of patient biases. The placebo ("sham") group will be obtained by placing a flexible silastic ring (inactivated Estring) high in the vagina where it will not alter urethral forces. The aim is to unequivocally determine whether the Uresta device provides the necessary urethral support to stop urine leakage from stress incontinence.
The hypothesis is that the Uresta device will significantly reduce urinary losses from baseline, shown as a significant reduction pad weight following a pad test with the device in place.
Conditions
- Stress Urinary Incontinence
Interventions
- DEVICE
-
Uresta pessary
Participants randomized to the Uresta group will be fitted with device before immediately before performing the pad test. The Uresta pessary is made of medical grade rubber that has been extensively tested for safety. It is bell-shaped, with a narrow tip that allows for easy insertion into the vagina in a similar fashion to a tampon. The device can be easily inserted, and removed by a patient for use when needed. The Uresta comes in 3 sizes. Fitting starts with insertion of the smallest size. If urine leakage continues with valsalva or a cough stress test, it can be replaced by one size larger, until leakage is stopped. If the device prevents the patient from being able to void or is uncomfortable due to its size, the smaller size is replaced. Following the pad test, the participant will be given the opportunity to keep the device for continued use, or remove it if desired.
- DEVICE
-
Silastic ring
The silastic ring is a plastic flexible ring similar to that used to administer vaginal estrogen (Estring). It is well tolerated and would not contain any medications. Immediately before performing the pad test, it would be placed high in the vagina, away from the urethra. It would be removed immediately after the pad test. Draping will conceal from the patient which device was inserted.
Sponsors & Collaborators
-
Mount Sinai Hospital, Canada
lead OTHER
Principal Investigators
-
Danny Lovatsis, MD MSc · Mount Sinai Hospital, Canada
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- FEMALE
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-01-31
- Primary Completion
- 2013-12-31
- Completion
- 2014-05-31
Countries
- Canada
Study Locations
More Related Trials
-
Canadian Experience With Contiform Intravaginal Device For The Treatment Of Stress Incontinence
NCT03614611 ·Status: TERMINATED ·Phase: NA
-
Stress Urinary Incontinence Physiotherapy
NCT02318251 ·Status: UNKNOWN ·Phase: NA
-
Pessary Experience Study
NCT06021769 ·Status: RECRUITING
-
Treatment of Stress Urinary Incontinence by Injection of Autologous Muscle Fibers Into the Urethral Sphincter.
NCT01323426 ·Status: UNKNOWN ·Phase: PHASE1/PHASE2
-
A Clinical Study to Assess the Safety of a Disposable Intra-vaginal Device for Stress Urinary Incontinence
NCT02160314 ·Status: COMPLETED ·Phase: NA
-
Elastographic Assessment of Suburethral Tissue in Continent and Incontinent Women
NCT06933407 ·Status: RECRUITING
-
Weighted Vaginal Cones Versus Biofeedback in the Treatment of Urodynamic Stress Incontinence: a Randomized Trial.
NCT00247286 ·Status: TERMINATED ·Phase: PHASE4
-
Tension-free Vaginal Tape Obturator for the Treatment of Urinary Incontinence -Long-term Follow-up
NCT04240613 ·Status: COMPLETED ·Phase: NA
-
Mid-Urethral Sling Tensioning Trial
NCT02480231 ·Status: COMPLETED ·Phase: NA
-
Ambulatory Pessary Trial
NCT02746913 ·Status: WITHDRAWN ·Phase: NA
-
Evaluation of the Efficacy and Safety of Advantage® Strips in Women Stress Urinary Incontinence (SUI )
NCT02927548 ·Status: COMPLETED
-
Prospective and Comparative Evaluation of a Medical Device Composed of a Perineal Probe Connected to a Mobile Application in the Management of Stress Urinary Incontinence.
NCT06285292 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
TVT-SECUR A Pilot Study for the Treatment of Stress Urinary Incontinence
NCT00463554 ·Status: COMPLETED
-
Pelvic Floor Displacement in Women With SUI and Healthy Women: An Ultrasound Study (Stress Urinary Incontinence)
NCT02930720 ·Status: UNKNOWN
-
Transobturator Urethral Sling Placement With an Autologous Rectus Facia
NCT03949348 ·Status: COMPLETED ·Phase: NA
-
Transobturator Sling Compared With Single-incision Mini-sling for the Treatment of Stress Urinary Incontinence
NCT02540525 ·Status: COMPLETED ·Phase: NA
-
Long-term Evaluation of the I-STOP Sling in Stress Urinary Incontinence Treatment
NCT06665698 ·Status: NOT_YET_RECRUITING
-
Trans-Obturator Tape Versus Trans-Vaginal Tape for Stress Urinary Incontinence in Women
NCT00234754 ·Status: COMPLETED ·Phase: NA
-
Effect of Peri-Urethral Stimulation on Intra-Urethral Pressure
NCT05900570 ·Status: RECRUITING ·Phase: NA
-
Is the Cough Stress Test Equivalent to the 24 Hour Pad Test in the Assessment of Stress Incontinence?
NCT01123096 ·Status: COMPLETED
-
Comparison of Two Over the Counter Intravaginal Devices for the Treatment of Stress Urinary Incontinence
NCT06698627 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Randomised Controlled Trial Comparing Tension-Free Vaginal Tape (TVT), Pelvicol & Autologous Slings for Stress Urinary Incontinence(SUI)
NCT01057550 ·Status: COMPLETED ·Phase: PHASE3
-
Treatment of Stress Urinary Incontinence Via Smartphone
NCT01848938 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Electroacupuncture (EA) for Women With Pure Stress Urinary Incontinence (SUI)
NCT02445573 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Transperineal US in Stress Incontinence
NCT03397368 ·Status: UNKNOWN