CANARY: Coronary Assessment by Near-infrared of Atherosclerotic Rupture-prone Yellow

NCT01268319 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 85

Last updated 2017-06-12

No results posted yet for this study

Summary

The CANARY (Coronary Assessment by Near-infrared of Atherosclerotic Rupture-prone Yellow) Study is a pivotal trial to evaluate criteria for defining a Lipid Core Plaque (LCP) that is at high risk of rupturing during standard of care therapy and causing intra-procedural complications. If plaques that require treatment are at higher than normal risk of causing intra-procedural complications, some life threatening, the treating physician is better informed and may opt to take precautionary measures to mitigate the risk or result of a complication. The CANARY Study is also designed to evaluate the feasibility of using a distal embolization protection device (EPD) as a means to prevent heart attacks triggered by the embolization of plaque during standard care therapy. It is thought that the EPD will prevent plaque from going downstream during treatment and obstructing other heart vessels. These obstructions could cause heart attacks by preventing blood from reaching heart muscle tissue.

Conditions

Interventions

DEVICE

Embolic Protection Device (EPD)

The embolic protection device consists of a protection wire, a delivery sheath, a retrieval sheath and various accessories (wire torque device, introducer, dilator tool). The wire of the EPD is used as a standard 0.014" steerable guide wire. The filter is designed for embolic debris capture while maintaining continuous blood flow. At the completion of the procedure, the filter and its contents are removed using the retrieval sheath and then removed from the patient.

DEVICE

Intracoronary Spectroscopy and Ultrasonic Evaluation

This intervention requires a near infrared imaging catheter equipped with an intravascular ultrasonic transducer be used to evaluate the coronary artery wall prior to treatment and after treatment. This system detects the lipid containing plaques that may be the source of embolic debris released during standard angioplasty and stent placement.

DEVICE

Angioplasty and Stent Implant

The target plaque will be treated with a pre-dilation with a standard angioplasty balloon sized to within 0.5mm of the diameter of the reference vessel diameter. The physician will then implant a coronary artery stent that is appropriately sized for the reference vessel diameter.

Sponsors & Collaborators

  • Infraredx

    lead INDUSTRY

Principal Investigators

  • Gregg W. Stone, M.D. · Columbia University

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2011-05-31
Primary Completion
2014-09-30
Completion
2016-11-30

Countries

  • United States

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.