Ultrasound Guided Cannulation of Dialysis Fistulas
NCT01163981 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 31
Last updated 2020-12-17
Summary
The investigators suspect that using ultrasound to guide insertion of needles for dialysis patients will make this process quicker and more accurate, thus reducing complications and reducing discomfort for patients.
Conditions
- Haemodialysis
Interventions
- OTHER
-
Use of ultrasound guidance in cannulation
Use of guidance with duplex ultrasound to complete cannulation of dialysis access
Sponsors & Collaborators
-
University of Hull
lead OTHER
Principal Investigators
-
George E Smith, BSc MBBS MRCS · Hull and East Yorkshire NHS Trust
Study Design
- Allocation
- RANDOMIZED
- Purpose
- SUPPORTIVE_CARE
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2016-11-30
- Primary Completion
- 2017-05-31
- Completion
- 2017-08-31
Countries
- United Kingdom
Study Locations
More Related Trials
-
Ultrasound-guided Cannulation of Difficult Hemodialysis Arteriovenous Access
NCT06381310 ·Status: RECRUITING ·Phase: NA
-
Creating a Buttonhole Tunnel Track by Repeated Needling of the AV Fistula on the Same Day in Patients on Hemodialysis.
NCT03989141 ·Status: COMPLETED ·Phase: NA
-
Simulation-based Training for Nurses and Arteriovenous Fistula Puncture in Chronic Hemodialysis Patients
NCT05302505 ·Status: COMPLETED ·Phase: NA
-
Indicating Direction and Angle for Cannulating of AV-fistula in Hemodialysis Patients
NCT01536548 ·Status: COMPLETED ·Phase: NA
-
Buttonhole Versus Step Ladder Cannulation in High Dose Hemodialysis
NCT01962025 ·Status: COMPLETED ·Phase: NA
-
Impact of Bevel Orientation on Arteriovenous Fistula Puncture in Hemodialysis
NCT06708338 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Role of Regular Surveillance on Maintenance of Patency of an Arteriovenous Access
NCT04098159 ·Status: UNKNOWN ·Phase: NA
-
Effect of Bevel Position of the Artery Needle on Puncture Pain and Post-puncture Bleeding Time
NCT05115448 ·Status: COMPLETED ·Phase: NA
-
Impact of the Arteriovenous Fistula Puncture Technique On the Hemodialysis Session For Patient and Caregiver
NCT03355508 ·Status: UNKNOWN ·Phase: NA
-
Clinical Values of Mature Fistulas in Hemodialysis
NCT04416971 ·Status: UNKNOWN
-
Open Versus Percutaneous Insertion of CAPD Catheters
NCT01023191 ·Status: WITHDRAWN ·Phase: NA
-
Preoperative Arteriovenous Fistula Simulation Study (ShuntSimulationStudy)
NCT02453412 ·Status: COMPLETED ·Phase: NA
-
The Effect of Coolsense Method on Pain and Comfort in Hemodialysis Patients
NCT06144801 ·Status: COMPLETED ·Phase: NA
-
Behind the Needle: Healthcare Professionals' Perspectives on HD Needling
NCT06845605 ·Status: RECRUITING
-
Stenosis of Arteria-Venous Fistula in Maintenance Hemodialysis Patients: Early Intervention Trial
NCT02266238 ·Status: UNKNOWN ·Phase: NA
-
Intravascular Ultrasound in Patients With End-stage Renal Disease on Dialysis
NCT04399941 ·Status: RECRUITING ·Phase: NA
-
Access Flow Based Intervention for Management of Arteriovenous Hemodialysis Access Dysfunction.
NCT02628119 ·Status: UNKNOWN ·Phase: NA
-
Acupuncture for Pain Management of Hemodialysis Patients
NCT01102816 ·Status: TERMINATED ·Phase: NA
-
Semi-blunt Needles: is Outcome Better?
NCT00840372 ·Status: COMPLETED
-
Hemodialysis in the Elderly (70yrs & Older)
NCT03065972 ·Status: UNKNOWN ·Phase: NA
-
A Comparative Study of Two Kinds of Hemodialysis Filters
NCT05899283 ·Status: COMPLETED ·Phase: NA
-
Response Of Arteriovenous Fistula Puncture-related Pain To Cryotherapy Application In Haemodialysis Patients
NCT06520631 ·Status: RECRUITING ·Phase: NA
-
A Feasibility Study to Test the Acceptability, Tolerance and Safety of Incremental Haemodialysis
NCT04268264 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Radial Artery Deviation And Reimplantation Technique for Primary Hemodialysis Access Creation
NCT02728817 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Reducing Hemodialysis Catheter Use in Prevalent Hemodialysis Patients
NCT01053117 ·Status: TERMINATED ·Phase: PHASE2