MD Logic Pump Advisor- Adults Study
NCT01157923 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 18
Last updated 2017-01-11
Summary
Prospective, randomized, controlled, 30-78 days trial comparing MD-Logic pump algorithm to the standard of care of patients with type 1 diabetes.
The objective of this feasibility study is to evaluate the efficacy and safety of automated determined Insulin pump settings (i.e., basal plan, correction factor, carbohydrate ration and insulin activity time) using the MD-Logic Pump Advisor in individuals with type 1 diabetes.The study will be consisted from two segments:(I)pilot study, 30-78 days trial evaluating the MD-Logic pump advisor and (II)randomized controlled 30-78 days trial comparing MD-Logic pump algorithm to the standard of care.In segment 1, the pilot study, the aim is to enroll 15-30 subjects without control group. In segment 2, the randomized controlled segment, the aim is to enroll 92 subjects, but enrolling up to 105 eligible subjects to allow for dropouts.
The randomized controled study segment will be initiated after the pilot segment.Each segment of the study will consist of 6 clinic visits taking place at intervals of 1-3 weeks, sum of 30-78 days study duration for each segment. Before each clinic visit, subjects will wear continuous glucose sensors for 6 days; the intervention group will have up to 4 iterations (e.g the pump setting will be reviewed and adjusted up to 4 times during the study period according to the MD-Logic Pump Advisor).For the control group (at segment 2 only), insulin pump settings will not be changed during the study period (patient's usual standard of care).
Conditions
- Type 1 Diabetes
- Insulin Pump Therapy
Interventions
- DEVICE
-
MD Logic Pump Advisor
Insulin pump settings (i.e., basal plan, correction factor, carbohydrate ration and insulin activity time) will be adjusted using the MD-Logic Pump Advisor
Sponsors & Collaborators
- collaborator INDUSTRY
-
Rabin Medical Center
lead OTHER
Principal Investigators
-
Moshe Phillip, Prof · Schenider Children's Medical
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 65 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2010-07-31
- Primary Completion
- 2016-07-31
- Completion
- 2016-07-31
Countries
- Israel
- Slovenia
Study Locations
More Related Trials
-
Inpatient Evaluation of the MD-Logic Artificial Pancreas System in Patients With Type 1 Diabetes
NCT01501032 ·Status: WITHDRAWN ·Phase: PHASE1
-
Overnight Type 1 Diabetes Control Under MD-Logic Closed Loop System at the Patient's Home
NCT01726829 ·Status: COMPLETED ·Phase: NA
-
MD-Logic Artificial Pancreas for Automatic Type 1 Diabetes Meals Management
NCT01901913 ·Status: COMPLETED ·Phase: NA
-
Use of an Automated Insulin Delivery System Compared to Sensor Augmented Pump at Patients With Type 1 Diabetes (T1D)
NCT02636491 ·Status: COMPLETED ·Phase: NA
-
Prevention of Hypoglycaemia With Predictive Insulin Suspend Using Sensor Augmented Insulin Pump in Children
NCT02179281 ·Status: COMPLETED ·Phase: NA
-
DreaMed Advisor Pro System in Subjects With Type 1 Diabetes Treated With MDI Therapy
NCT04043260 ·Status: COMPLETED ·Phase: NA
-
Feasibility Study of the Solo™ Insulin Pump
NCT01055951 ·Status: COMPLETED ·Phase: PHASE1
-
Fuzzy Logic Automated Insulin Regulation
NCT03040414 ·Status: COMPLETED ·Phase: NA
-
Assessing the Safety, Performance, and User Experience of the Tandem Mobi Automated Insulin Delivery System Among Young Competitive Athletes in Real-world Settings.
NCT06979635 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
The Effects of Regular Home Use Vs Diabetic Team- Supported Use of the Medtronic CareLink Therapy Management System.
NCT00814476 ·Status: COMPLETED ·Phase: PHASE4
-
OpT2mise Glucose Control in Type 2 Diabetes Mellitus (DM) With Insulin Pump Therapy
NCT01182493 ·Status: COMPLETED ·Phase: NA
-
Prevention of Hypoglycemia After Exercise Using Closed Loop System in Children and Adolescents With Type 1 Diabetes
NCT02657083 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 12 Days in Adults With Type 1 Diabetes
NCT02846831 ·Status: COMPLETED ·Phase: PHASE2
-
New Glucose Sensor Pediatric
NCT01161043 ·Status: COMPLETED ·Phase: NA
-
Prospective Evaluation of a Dose Guidance System for People With Diabetes Initiating Basal Insulin or Using Insulin Injections
NCT06966427 ·Status: RECRUITING ·Phase: NA
-
Evaluation of a Novel Method for Integrating Insulin Delivery and Glucose Sensing in Adipose Tissue of Diabetic Patients
NCT00813410 ·Status: COMPLETED ·Phase: NA
-
Performance Study to Test the GlucoMen®Day System Using Intravascular and Subcutaneous Microdialysis in Subjects With Type 1 Diabetes
NCT01709851 ·Status: COMPLETED
-
Study to Compare Efficacy of the MiniMed Paradigm REAL-Time System Vs. MDI in Subjects Naive to Insulin Pump Therapy
NCT00417989 ·Status: COMPLETED ·Phase: NA
-
Insulin Degludec Titration Using Mobile Insulin Dosing System
NCT03091712 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a Decision Support System for People With Diabetes Who Use Multiple Daily Insulin Injections- Feasibility and Proof of Concept Studies
NCT04653961 ·Status: RECRUITING ·Phase: NA
-
Use of the Paradigm 722 System to Improve Glycemic Control in Adult and Adolescent Subjects With Type 1 Diabetes
NCT00211510 ·Status: COMPLETED ·Phase: NA
-
Feasibility Study - Integrated Sensor and Infusion Set. Trial III
NCT01773668 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy of 7-day Wear Infusion Set vs. Control Infusion Set.
NCT04208282 ·Status: COMPLETED ·Phase: NA
-
Dual-hormone Artificial Pancreas Versus Single-hormone Under Exercise and a Meal Challenge
NCT06082973 ·Status: COMPLETED ·Phase: NA
-
MEDTRUM A7+ TouchCare Insulin Patch Pump (MedInPS)
NCT04223973 ·Status: COMPLETED ·Phase: NA