Volar Locked Plating Versus Bridging External Fixation

NCT01062997 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 166

Last updated 2016-08-09

No results posted yet for this study

Summary

A randomized, prospective comparison of volar locked plating versus Hoffman II bridging external fixation supplemented by K-wire fixation in patients with comminuted distal radius fractures, AO/OTA type C2 \& C3.

Hypothesis:

There is no significant difference in using volar plates compared to Hoffman II bridging external fixation supplemented by K-wire fixation in patients with comminuted distal radius fractures, AO/OTA type C2 \& C3 as evaluated by a Quick-DASH score at 24 months follow-up.

Conditions

  • Distal Radius Fracture

Sponsors & Collaborators

  • University of Oslo

    collaborator OTHER
  • Haukeland University Hospital

    collaborator OTHER
  • University Hospital, Akershus

    lead OTHER

Eligibility

Min Age
18 Years
Max Age
70 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2009-09-30
Primary Completion
2015-12-31
Completion
2016-04-30

Countries

  • Norway

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.