Evaluation of Safety and Efficacy of Using EndyMed Pro Skin Treatment System for Skin Wrinkle Treatment on Body Areas
NCT01029301 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2009-12-09
Summary
Skin aging is a multifactorial process involving the 3 layers of the skin: Epidermis, dermis and hypodermis. Skin aging process involves among others: skin roughness (epidermis), skin dyschromia (epidermis, dermis), wrinkles and elastosis - skin texture changes due to collagen modification, skin laxity and cellulite (dermis and hypodermis).
EndyMed has developed the EndyMed Pro system - Computerized Radiofrequency System for Skin Tightening. By using a multielectrodes treatment tip an exact computerized thermal pattern can be produced allowing to selectively heating one or more of the target tissues (epidermis, dermis and hypodermis). In the skin tightening module the dermis and hypodermis would be targeted, creating enough thermal effect to induce collagen remodeling with no ablative thermal damage in the epidermis or dermis. This post marketing study is intended for evaluation of safety and efficacy of the EndyMed Pro system.
Conditions
- Skin Aging
- Skin Wrinkling
Interventions
- DEVICE
-
Device: EndyMed Pro System for Skin Tightening
Based on patient skin type and area of treatment the physician will choose the following parameters (some parameters are fixed): Pulse energy (J); RF frequency (1MHz); Pulse duration (30 sec); Treatment hand piece (skin tightening);
Sponsors & Collaborators
-
Endymion Medical Ltd
lead INDUSTRY
Principal Investigators
-
Varda Godfried, Dr. · EndyMed Medical Ltd
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 30 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2008-11-30
- Primary Completion
- 2009-11-30
- Completion
- 2009-11-30
More Related Trials
-
EN3835 for the Treatment of Edematous Fibrosclerotic Panniculopathy (Commonly Known as Cellulite)
NCT02724644 ·Status: COMPLETED ·Phase: PHASE2
-
Evaluation of Safety and Efficacy of Micro-coring Device for Treatment of Facial Wrinkles and Skin Laxity
NCT03228641 ·Status: COMPLETED ·Phase: NA
-
Pilot Evaluation of the Cynosure Potenza™ System for Treatment of Cosmetic Dermatologic Skin Conditions
NCT05847530 ·Status: COMPLETED ·Phase: NA
-
Safety Study of Filler Agent Composed of Umbilical Cord Mesenchymal Stem Cells and Hyaluronic Acid
NCT02698813 ·Status: UNKNOWN ·Phase: PHASE1
-
Evaluation of the Anti-aging Efficacy of a Novel Skin Health Product
NCT05300984 ·Status: COMPLETED ·Phase: NA
-
Phase 1 Study of the Effects of Combining Topical FDA-approved Drugs on Age-related Pathways on the Skin of Healthy Volunteers
NCT03072485 ·Status: COMPLETED ·Phase: PHASE1
-
Efficacy of Micro-excisional Skin Removal by Micro-coring Device in Treatment of Wrinkles and Laxity of Face and Neck
NCT03583918 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy Evaluation of the Monopolar Radiofrequency Device for the Improvement of Facial Wrinkles
NCT06657365 ·Status: COMPLETED ·Phase: NA
-
Comparison Of Aesthetic Techniques For Rejuvenation Of Genital Region: A Randomized Clinical Trial
NCT04998578 ·Status: RECRUITING ·Phase: NA
-
Durability and Safety of CCH With Two Different Injection Techniques in Cellulite With Laxity
NCT05249257 ·Status: COMPLETED
-
The Effects of Microdermabrasion on Skin Remodeling
NCT00111254 ·Status: COMPLETED ·Phase: NA
-
MĒ Device for At-Home Skin Rejuvenation
NCT02902718 ·Status: UNKNOWN ·Phase: NA
-
Safety and Effectiveness of Sculptra Aesthetic for Correction of Cheek Wrinkles
NCT04124692 ·Status: COMPLETED ·Phase: NA
-
A Trial of Skin Care Protocols for Facial Resurfacing
NCT01113606 ·Status: COMPLETED ·Phase: PHASE4
-
Study on Safety and Efficacy of Monopolar Radio Frequency Device for Facial Skin Tightening
NCT06816069 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Feasibility Study to Collect and Assess Safety Data for a Radiofrequency Microneedling Device for Electrocoagulation and Hemostasis of Soft Tissues for Dermatologic Conditions
NCT05987319 ·Status: RECRUITING ·Phase: NA
-
Aesthetic Performance and Tolerance of an Injective Intradermal Treatment for the Skin Roughness and Laxity of Back of the Hands
NCT05590364 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Anti-aging Efficacy of Four Skin Health Products
NCT05473832 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Efficacy and Safety of the Skinstylus Sterilock Microneedling System for the Treatment of Facial Wrinkles
NCT06032286 ·Status: COMPLETED ·Phase: NA
-
Efficacy of an Antiage Aesthetic Treatment for the Middle and Inferior Third of the Face
NCT04239768 ·Status: COMPLETED ·Phase: NA
-
Tolerability and Efficacy of Anti-Aging Treatment Regimen in Subjects With Photodamage
NCT02422836 ·Status: COMPLETED ·Phase: NA
-
Microneedle Versus Fractional CO₂ Laser for Skin Aging Treatment With Stem Cell Secretome in Indonesian Adult Women
NCT05508191 ·Status: COMPLETED ·Phase: NA
-
Mechanisms for Laser-Induced Rejuvenation
NCT06489301 ·Status: RECRUITING ·Phase: NA
-
Biological Anti-aging Efficacy of a Cosmetic Night Cream
NCT06433323 ·Status: COMPLETED
-
A Study on the Anti-Wrinkle Efficacy Assessment and Safety Evaluation of the Cluster of Autologous Dermal Fibroblast on Bilateral Crow's Feet
NCT04818203 ·Status: RECRUITING ·Phase: PHASE1/PHASE2