IRIS PILOT - Extended Pilot Study With a Retinal Implant System
NCT00427180 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2010-03-03
Summary
Investigate whether blind subjects that fulfil the patient criteria provided with a Retinal Implant are able to differentiate between simple patterns like horizontal bar, vertical bar and cross.
Conditions
- Retinitis Pigmentosa
- Cone-Rod Dystrophy
- Choroideremia
Interventions
- DEVICE
-
Retinal Implant System (IRIS)
AIMD - Active Implantable Medical Device designed for artificial electrical neural stimulation of photoreceptor degenerated retina
Sponsors & Collaborators
-
Intelligent Medical Implants GmbH
lead INDUSTRY
Principal Investigators
-
Gisbert Richard, Prof. · Klinik und Poliklinik für Augenheilkunde Hamburg-Eppendorf
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 30 Years
- Max Age
- 79 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2006-12-31
- Primary Completion
- 2010-11-30
- Completion
- 2010-12-31
More Related Trials
-
Sutureless Technique for Repositioning and Scleral Fixation of the Capsular Bag - Intraocular Lens Complex With Permanent Use of Iris Retractors
NCT07257172 ·Status: RECRUITING ·Phase: NA
-
Study of Demarcation Line Depth in Transepithelial Versus Epithelium-off Accelerated Cross-linking (AXL) in Keratocouns
NCT04045626 ·Status: UNKNOWN ·Phase: NA
-
Visual Acuity After the Combined Binocular Implantation of +2.5 Diopters and +3.0 Diopters ReSTOR Multifocal Intraocular Lenses.
NCT02314572 ·Status: COMPLETED ·Phase: PHASE4
-
Clinical Investigation of Visual Function After Bilateral Implantation of Two Presbyopia-Correcting Trifocal Intraocular Lenses (IOL)
NCT02691741 ·Status: COMPLETED ·Phase: NA
-
Argus II Retinal Prosthesis System - Better Vision RP Study
NCT03418116 ·Status: WITHDRAWN ·Phase: NA
-
Longitudinal Study of a Bionic Eye
NCT05158049 ·Status: ENROLLING_BY_INVITATION
-
A Phase I Feasibility Study of an Intracortical Visual Prosthesis (ICVP) for People With Blindness
NCT04634383 ·Status: UNKNOWN ·Phase: NA
-
IRIS Registry: Intelligent Research in Sight Registry
NCT02485847 ·Status: RECRUITING
-
Post-Approval Study of the Implantable Miniature Telescope
NCT01757132 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Toric Intraocular Lens (IOL) Implantation for Management of Cataracts
NCT05797298 ·Status: RECRUITING
-
Visual Function After Implantation of Bilateral AcrySof® Toric Natural Intraocular Lens
NCT00760487 ·Status: COMPLETED ·Phase: PHASE4
-
Quality of Vision in Implantable Collamer Lens (ICL)
NCT04982107 ·Status: COMPLETED
-
Visual Acuity After the Combined Binocular Implantation of +2.75 Diopters and +3.25 Diopters Tecnis Multifocal Intraocular Lenses.
NCT02633072 ·Status: COMPLETED ·Phase: PHASE4
-
Pilot Clinical Investigation of Adaptative Eyeglasses for the Correction of Presbyopia
NCT05326607 ·Status: COMPLETED ·Phase: NA
-
Low Cylinder Toric
NCT00732030 ·Status: COMPLETED ·Phase: PHASE4
-
Clinical Evaluation of a New Cartridge for the Implantation of Foldable Intraocular Lenses
NCT01396629 ·Status: COMPLETED
-
Improving Visual Quality in Patients With Irregular Corneas Using Asymmetrical Toric Intraocular Lenses
NCT07294716 ·Status: RECRUITING ·Phase: NA
-
Vision Improvement for Patients With Age-Related Macular Degeneration
NCT04268836 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Visual Acuity and Patient Satisfaction With AT LISA TRI 839MP Intraocular Lenses
NCT01731743 ·Status: COMPLETED ·Phase: NA
-
Clinical Assessment of Visual Function With the Acrysof ReSTOR Multifocal IOL
NCT00759096 ·Status: COMPLETED ·Phase: NA
-
Visual Function and Patient Satisfaction After Bilateral Implantation of AcrySof Natural ReSTOR (Model SN60D3) or AcrySof Natural Monofocal (Model SN60AT)
NCT00759668 ·Status: COMPLETED ·Phase: NA
-
Ocular Biomarkers for Successful Premium Trifocal Intra-ocular Lenses Implantation
NCT05863247 ·Status: UNKNOWN
-
Evaluation of Visual Outcomes of Monovision Patients Bilaterally Implanted With Nanoflex Intraocular Lenses
NCT01279122 ·Status: UNKNOWN ·Phase: PHASE4
-
Visual Acuity After the Combined Binocular Implantation of +2.0 Diopters and +3.0 Diopters Oculentis Multifocal Intraocular Lenses.
NCT02633228 ·Status: COMPLETED ·Phase: PHASE4
-
Analysis of Influencing Factors of High-Order Aberrations of SMILE With Lenticule Retained
NCT06806085 ·Status: RECRUITING