Safety and Efficacy Study Comparing Thrombin for Arterial Sealing
NCT00388284 · Status: COMPLETED · Phase: PHASE3 · Type: INTERVENTIONAL · Enrollment: 270
Last updated 2015-12-09
Summary
This trial is designed as a prospective, multi-center, randomized, double blinded clinical trial to evaluate the safety and efficacy of the Thrombin VSI. An immunological sub-study to assess antibody and coagulation changes in the subjects following exposure to the Vascular Solutions Diagnostic Duett Pro manufactured with Thrombin VSI and Thrombin JMI will be conducted as a component of this trial with a subset of the enrolled study subjects.
Two hundred seventy (270) subjects will be enrolled in this trial. A minimum of 50% of the subjects will be interventional subjects and up to 50% will be diagnostic subjects. All 270 subjects will provide blood specimens at baseline and at the 30 day follow-up visit for evaluation in the immunologic sub-study. Within the 270 subjects enrolled, a minimum of 45 subjects treated with the Thrombin VSI and a minimum of 45 subjects treated with the Thrombin JMI will provide blood specimens at the 60 day follow-up visit to be evaluated in the immunologic sub-study.
The primary efficacy objective is to demonstrate that the device time-to-hemostasis for the study group treated with the sealing device manufactured with Thrombin VSI is non-inferior to the study group treated with the sealing device manufactured with Thrombin JMI.
The primary safety objective is to demonstrate a device-related major complication rate for the study group treated with the sealing device manufactured with Thrombin VSI that is non-inferior to the device-related major complication rate observed for the study group treated with the sealing device manufactured with Thrombin JMI.
Conditions
- Hemostasis of Arterial Punctures
Interventions
- DEVICE
-
Arterial Sealing
Sponsors & Collaborators
-
Vascular Solutions LLC
lead INDUSTRY
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2006-08-31
- Primary Completion
- 2007-03-31
- Completion
- 2007-03-31
Countries
- United States
Study Locations
More Related Trials
-
Post-market Clinical Investigation of the Angio-Seal™ VIP VCD (ANGIO-SEAL CLOSE)
NCT05335525 ·Status: UNKNOWN
-
Feasibility and Safety of Total Percutaneous Closure of Femoral Arterial Access Sites in the Veno-arterial ECMO Patients
NCT04689451 ·Status: UNKNOWN
-
A Study to Evaluate the Safety and Performance of ArterX™ Vascular Sealant in Sealing Synthetic Arterial Grafts
NCT02476318 ·Status: COMPLETED ·Phase: NA
-
Trial Comparison of Accuseal and Bovine Pericardial Patch During Endarterectomy
NCT01184183 ·Status: COMPLETED
-
Post-Market Clinical Investigation of the FemoSeal™ VCS: A Prospective, Multi-Center Observational European Study
NCT05027698 ·Status: COMPLETED
-
The Safety and Efficacy of the Suture-Mediated Closure System
NCT05841836 ·Status: UNKNOWN ·Phase: NA
-
Post-Market Study of the St. Jude Medical Angio-Seal™ V-Twist Integrated Platform (VIP) Vascular Closure Device
NCT01858636 ·Status: COMPLETED
-
InSeal VCD Large Bore Vascular Closure Device Safety and Effectiveness Clinical Study
NCT02628782 ·Status: COMPLETED ·Phase: NA
-
Safety and Performance Study of Large Hole Vascular Closure Device
NCT02788448 ·Status: COMPLETED ·Phase: NA
-
Clinical Investigation for Safety and Efficacy Study of CELT ACD (Arterial ClosureDevice)
NCT01600482 ·Status: COMPLETED ·Phase: NA
-
CaveoVasc Thrombolysis Protection System, Access Protection Study
NCT03166059 ·Status: UNKNOWN ·Phase: NA
-
Access Safety and Efficacy Post Endovascular Intervention
NCT01773148 ·Status: UNKNOWN ·Phase: NA
-
Study of IVC Filter Retrieval With the Günther Tulip Vena Cava Filter
NCT00196118 ·Status: COMPLETED ·Phase: PHASE4
-
The Performance / Safety of the Celsite® Venous Access Ports
NCT05572112 ·Status: UNKNOWN
-
Characteristics Predictive of Success and Complications in the Use of Suture-Mediated Closure of Femoral Venous Access
NCT00838175 ·Status: UNKNOWN
-
InSeal Vascular Closure Device Clinical Study Protocol
NCT01896401 ·Status: TERMINATED ·Phase: NA
-
Comparison of the Hemostatic Patch to Fibrin Sealant (TachoSil®) in Subjects Undergoing Hepatic Surgery
NCT01324349 ·Status: COMPLETED ·Phase: NA
-
The AbsorbaSeal Vascular Closure Device Trial
NCT03730571 ·Status: TERMINATED ·Phase: NA
-
Clinical Trial of a Silver Eluting Dressing System
NCT01229358 ·Status: COMPLETED ·Phase: PHASE4
-
Use of the Venous Coupler in Breast Reconstruction by Means of a Deep Inferior Epigastric Perforator: Reduction of Surgery Length and Venous Thromboses ?
NCT03340623 ·Status: COMPLETED
-
Crux Biomedical Evaluation of the Crux Inferior Vena Cava Filter System 3 ("RETRIEVE 3")
NCT01120522 ·Status: COMPLETED ·Phase: PHASE3
-
VenaTech Convertible Vena Cava Filter U.S. Multi-Center Clinical Trial
NCT01112917 ·Status: COMPLETED ·Phase: NA
-
Predicting the Safety and Effectiveness of Inferior Vena Cava Filters
NCT02381509 ·Status: COMPLETED
-
X-Seal EU Post-Market Clinical Follow-Up Protocol
NCT02406612 ·Status: COMPLETED ·Phase: NA
-
Study to Compare CAUTI Rates Following ERASE CAUTI Tray Silver vs Silver Coated Foley Catheters
NCT02915692 ·Status: TERMINATED