NIRS Monitoring in the Ambulatory Single Ventricle Patient
NCT00166218 · Status: TERMINATED · Type: OBSERVATIONAL · Enrollment: 30
Last updated 2013-11-27
Summary
The normal heart has four chambers. There are two upper (or filling) chambers and are called the atrium. There are two lower (or pumping) chambers and are called the ventricles. One of the ventricles pumps blood to the lungs to get oxygen. This oxygenated blood is returned to the heart then pumped to the rest of the body by the other ventricle.
Sometimes babies are born with heart defects that only allow one of the lower chambers (ventricle) to work properly. This means that the one ventricle must pump blood to both the lungs and to the rest of the body. Babies born with this defect must undergo multiple surgeries, the first of which is usually done during their first week of life.
There is a machine that is FDA approved that can measure how much oxygen is delivered to the brain. This non-invasive (outside the body) machine uses Near-infrared spectroscopy (NIRS), which is similar technology used in pulse oximetry and is routinely used to measure the level of oxygen in blood. At Children's Healthcare of Atlanta, we typically place the NIRS machine on the baby in the Cardiac Intensive Care Unit immediately after their first surgery to monitor oxygen delivery to the brain. The monitor has proven to be accurate in this situation.
We now want to know if we can use this monitor to assess oxygen delivery to the brain before and during a routine heart catheterization prior to the child's second surgery. Once consent is obtained, we will place a probe on the child's forehead during the pre-catheterization visit and obtain readings for 5 minutes. The probes are about the size of a quarter and are self-stick (they look like the kind of leads used to measure the babies heart rate \[EKG\]). The machine will be disconnected for the rest of the Pre-catheterization visit, however the probes will stay on the child's forehead. Once the child is in the catheterization suite, the machine will be reconnected. A sheath or hollow tube is routinely placed in a blood vessel in the child's neck or groin for the catheterization. The doctor would place a special catheter in this sheath that measures oxygen levels in blood continuously. This monitor would be calibrated by using the results of a blood sample that is routinely drawn from the child's IV. During the same sampling, an additional 2cc's of blood would be collected to measure the lactate level. The lactate level is an indicator of how well the child is using oxygen. Once this monitor is calibrated, data will be collected for 5 minutes to compare it with the NIRS machine. The special catheter will be removed after the 5-minute time period, and the catheterization will proceed as usual. The NIRS probes will stay on the child's forehead during the entire catheterization with the data documented. At the end of the catheterization, the probes will be removed.
Conditions
- Ambulatory Children With Single Ventricle
Interventions
- DEVICE
-
near-infrared spectroscopy
Sponsors & Collaborators
-
Emory University
lead OTHER
Principal Investigators
-
Robert Vincent, MD · Emory University
Eligibility
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2004-02-29
- Completion
- 2005-02-28
Countries
- United States
Study Locations
More Related Trials
-
Using Tissue Doppler/Synchronization to Determine Heart Function in Children With Congenital Heart Disease
NCT00208676 ·Status: TERMINATED
-
Examining Developmental Changes in Heart Contractions of Children With Congenital Heart Defects
NCT00860327 ·Status: TERMINATED
-
Rhythm Disturbances After Ventricular Septal Defects
NCT00208624 ·Status: TERMINATED
-
Biomarker Study for Heart Failure in Children With Single Ventricle Physiology
NCT00571233 ·Status: COMPLETED
-
Infant Nasal Nitric Oxide Levels in Congenital Heart Disease
NCT02551107 ·Status: TERMINATED ·Phase: NA
-
Functional Muscle Characteristics and Cardio-respiratory Interaction in Patients With Fontan Palliation
NCT04151004 ·Status: COMPLETED ·Phase: NA
-
Study of Intramyocardial Injection of Ventrix Bio Extracellular Matrix (VentriGel) to Assess the Safety and Feasibility in Pediatric Patients with Hypoplastic Left Heart Syndrome (HLHS)
NCT06461676 ·Status: NOT_YET_RECRUITING ·Phase: PHASE1
-
Cerebral Blood Flow in Single Ventricles Throughout Staged Surgical Reconstruction
NCT02135081 ·Status: COMPLETED
-
Nutritional Failure in Infants With Single Ventricle Congenital Heart Disease
NCT01821287 ·Status: COMPLETED
-
Use of Color Doppler in Routine Examination of Fetal Heart in Second Trimester
NCT01201486 ·Status: COMPLETED
-
Impact of Exercise Training on Single Ventricle Function in Paediatric Fontan Patients
NCT05617534 ·Status: UNKNOWN
-
Effects of Pulmonary Vasodilation Upon VA Coupling in Fontan Patients
NCT01607983 ·Status: WITHDRAWN ·Phase: PHASE3
-
Fetal Heart Rate Variability
NCT04323865 ·Status: COMPLETED
-
Speckle Tracking Echocardiography in Infants, Prenatally and Postnatally
NCT05601375 ·Status: UNKNOWN
-
Evaluating Precision of Therapy - Milrinone
NCT01841177 ·Status: COMPLETED ·Phase: PHASE2
-
The Relationship Between Fetal Baseline Heart-rate and the Level of Acetyl-choline Esterase in Fetal Blood
NCT03478267 ·Status: COMPLETED
-
Retrospective Evaluation of Carvedilol Versus Captopril in CHF Patients
NCT00249067 ·Status: TERMINATED
-
Microcirculation and Vascular Function After Fontan Surgery
NCT05683067 ·Status: UNKNOWN
-
Cardiac Biomarkers in Pediatric Cardiomyopathy (PCM Biomarkers)
NCT01873976 ·Status: UNKNOWN
-
Pediatric Cardiomyopathy Mutation Analysis
NCT02432092 ·Status: RECRUITING
-
Right Ventricular Failure in Congenital Heart Defects
NCT00266201 ·Status: COMPLETED
-
Critical Congenital Heart Defect (CHD) Outcomes in Children
NCT00208689 ·Status: TERMINATED
-
Variability of Ventricular Mass, Volume, & Ejection Fraction in Pediatric Cardiomyopathy Patients-Pediatric Heart Network
NCT00123071 ·Status: COMPLETED
-
Cerebral Anatomy, Hemodynamics and Metabolism
NCT02919956 ·Status: COMPLETED
-
Normal Reference Range for Neonatal Echocardiography
NCT05462301 ·Status: RECRUITING